Dynamics of hip artificial joints wear

被引:0
|
作者
Capitanu, L. [1 ]
Iarovici, A. [1 ]
Onisoru, J. [1 ]
Tiganesteanu, C. [1 ]
Dima, M. [1 ]
机构
[1] Romanian Acad, Inst Solid Mech, Bucharest, Romania
来源
JOURNAL OF THE BALKAN TRIBOLOGICAL ASSOCIATION | 2008年 / 14卷 / 01期
关键词
wear; biotribology; total hip prostheses;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In the present paper the authors try to evaluate, based on the results obtained from experimental and numerical previous studies, the wear evolution in the components of a total hip prosthesis (THP), during the service period. Topographic investigations of polyethylene cup and femoral head surfaces of a modular total hip prosthesis retrieved after a service period of 10 years, are made. The aim of the study was the determination of. state of surfaces (roughness, microhardness), surfaces wear type, localisation and microscopic investigation of damages, wear mechanism identification.
引用
收藏
页码:76 / 86
页数:11
相关论文
共 50 条
  • [31] Volumetric determination of the wear of ceramics for hip joints
    Serra, E
    Tucci, A
    Esposito, L
    Piconi, C
    BIOMATERIALS, 2002, 23 (04) : 1131 - 1137
  • [32] FRICTION AND LUBRICATION OF ARTIFICIAL HIP JOINTS
    UNSWORTH, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (02): : 252 - 253
  • [33] Frictional properties of artificial hip joints
    Unsworth, A.
    Pearcy, M.J.
    White, E.F.T.
    White, G.
    Engineering in Medicine, 1988, 17 (03): : 101 - 104
  • [34] Artificial hip joints: The biomaterials challenge
    Pezzotti, Giuseppe
    Yamamoto, Kengo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 31 : 3 - 20
  • [35] Artificial Hip Joints adapt precisely
    不详
    UNFALLCHIRURG, 2015, 118 (07): : 585 - 585
  • [36] DEVELOPMENT AND USE OF ARTIFICIAL HIP JOINTS
    MCKEE, GK
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1963, 45 (03): : 616 - 616
  • [37] Wear of artificial hip joint material
    Watters, EPJ
    Spedding, PL
    Grimshaw, J
    Duffy, JM
    Spedding, RL
    CHEMICAL ENGINEERING JOURNAL, 2005, 112 (1-3) : 137 - 144
  • [38] New joints for the Millennium: wear control in total replacement hip joints
    Dowson, D
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H4) : 335 - 358
  • [39] Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints
    Elsner, Jonathan J.
    Mezape, Yoav
    Hakshur, Keren
    Shemesh, Maoz
    Linder-Ganz, Eran
    Shterling, Avi
    Eliaz, Noam
    ACTA BIOMATERIALIA, 2010, 6 (12) : 4698 - 4707
  • [40] Nonlinear vibration and dynamics of ceramic on ceramic artificial hip joints: a spatial multibody modelling
    Ehsan Askari
    Paulo Flores
    Danè Dabirrahmani
    Richard Appleyard
    Nonlinear Dynamics, 2014, 76 : 1365 - 1377