Comparison of electron temperature in DC glow discharge and AC glow discharge plasma

被引:5
|
作者
Tangjitsomboon, P. [1 ,4 ]
Ngamrungroj, D. [2 ,4 ]
Mongkolnavin, R. [3 ,4 ]
机构
[1] Navamindradhiraj Univ, Fac Sci & Hlth Technol, Dept Gen Educ, Bangkok 10300, Thailand
[2] King Mongkuts Univ Technol North, Dept Social & Appl Sci, Coll Ind Technol, Bangkok 10820, Thailand
[3] Chulalongkorn Univ, Dept Phys, Fac Sci, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Plasma Technol & Nucl Fus Res Unit, Bangkok 10330, Thailand
关键词
D O I
10.1088/1742-6596/1380/1/012022
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Knowing electron temperature and electron density is important for any plasma related applications. In this research, the electron temperature and electron density of argon plasma generated by low frequency AC power supply and a high voltage DC power supply were investigated. The measurements were compared, both experimentally and theoretically. For the experiment, a long glass cylindrical tube was used as a chamber where the electrodes were placed at 37.5 cm apart. A high voltage function generator power supply was operated at various frequencies and it was also used for DC operation. The electron temperatures were measured by Optical Emission Spectroscopy (OES) technique for different operating pressures of 0.1 mbar, 0.6 mbar and 1.1 mbar. For the simulation, both plasma theory and finite element method were used to simulate dynamics of the plasma in the cylindrical setup. From the experiment, the range of breakdown voltage was found to be between 0.80 to 2.3 kV. The length of DC glow discharge dark regions of the plasma decreases due to increasing in both operating pressure and voltage. AC glow discharge shows positive charge and negative charge swing. From the DC discharge, the maximum value of electron temperature was found to be 0.810 eV and the minimum value was 0.610 eV under the operating pressure 0.1 and 0.6 mbar respectively. From AC glow discharge plasma, the maximum electron temperature was 0.907 eV and the minimum was 0.540 eV under operating pressure 0.1 and 1.1 mbar respectively. Collision loss between ions and electrons causes this variation in the results.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Dusty plasmas in a dc glow discharge
    Fortov, VE
    Nefedov, AP
    Molotkov, VI
    Petrov, OF
    Poustylnik, MY
    Torchinsky, VM
    Khrapak, AG
    DUSTY PLASMAS IN THE NEW MILLENNIUM, 2002, 649 : 394 - 397
  • [42] Dust acoustic waves in a dc glow-discharge plasma
    Molotkov, VI
    Nefedov, AP
    Torchinskii, VM
    Fortov, VE
    Khrapak, AG
    JOURNAL OF EXPERIMENTAL AND THEORETICAL PHYSICS, 1999, 89 (03) : 477 - 480
  • [43] Distribution of gas temperature in an unconfined glow discharge plasma
    Soukhomlinov, VS
    Sheverev, VA
    Ötügen, MV
    JOURNAL OF APPLIED PHYSICS, 2003, 94 (02) : 844 - 851
  • [44] Shock wave formation in a dc glow discharge dusty plasma
    Fortov, VE
    Petrov, OF
    Molotkov, VI
    Poustylnik, MY
    Torchinsky, VM
    Naumkin, VN
    Khrapak, AG
    PHYSICAL REVIEW E, 2005, 71 (03)
  • [45] Dust acoustic waves in a dc glow-discharge plasma
    V. I. Molotkov
    A. P. Nefedov
    V. M. Torchinskii
    V. E. Fortov
    A. G. Khrapak
    Journal of Experimental and Theoretical Physics, 1999, 89 : 477 - 480
  • [46] Investigation of H- production in plasma of dc glow discharge
    Belostotsky, S. G.
    Lopaev, D. V.
    Rakhimova, T. V.
    FIRST INTERNATIONAL WORKSHOP AND SUMMER SCHOOL ON PLASMA PHYSICS, 2006, 44 : 162 - +
  • [47] Plasma properties of the DC glow discharge in wire ion plasma source
    Urai, H
    Mashio, K
    Okino, A
    Hotta, E
    ICPP 96 CONTRIBUTED PAPERS - PROCEEDINGS OF THE 1996 INTERNATIONAL CONFERENCE ON PLASMA PHYSICS, VOLS 1 AND 2, 1997, : 1554 - 1557
  • [48] Fluorination of polymethylmethaacrylate with tetrafluoroethane using DC glow discharge plasma
    Guruvenket, S.
    Iyer, Ganjigunte R. S.
    Shestakova, Larisa
    Morgen, Per
    Larsen, N. B.
    Rao, G. Mohan
    APPLIED SURFACE SCIENCE, 2008, 254 (18) : 5722 - 5726
  • [49] Plasma parameters and chemical kinetics of an HCl DC glow discharge
    Efremov, A. M.
    Kim, G. H.
    Balashov, D. I.
    Kim, C. I.
    VACUUM, 2006, 81 (03) : 244 - 250
  • [50] Radial Distributions of Dusty Plasma Parameters in a DC Glow Discharge
    Sukhinin, G. I.