Comparison of Dissolved Gas-in-Oil Analysis Methods Using a Dissolved Gas-in-Oil Standard

被引:26
|
作者
Lelekakis, Nick [1 ]
Martin, Daniel [1 ]
Guo, Wenyu [1 ]
Wijaya, Jaury [1 ]
机构
[1] Monash Univ, TransformerLIFE Ctr, Ctr Power Transformer Monitoring Diagnost & Life, Clayton, Vic 3800, Australia
关键词
dissolved gas analysis; Shake Test; vacuum extraction; headspace;
D O I
10.1109/MEI.2011.6025366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved gas analysis (DGA) is routinely used to determine the concentrations of gases dissolved in the insulating oil of transformers. These concentrations are used to investigate and diagnose electrical or thermal faults [1]. Such faults cause the transformer oil, pressboard, and other insulating materials to decompose and generate gases, some of which dissolve in the oil. The results of DGA must be accurate if faults are to be diagnosed reliably. Commercial testing laboratories understandably prefer measurements that can be made easily and quickly. In this paper, DGA results from five independent testing laboratories are compared and discussed. A dissolved gas-in-oil standard with known dissolved gas concentrations was used as the basis of comparison. © 2006 IEEE.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [41] Influence of Oil Quality on the Interpretation of Dissolved Gas Analysis Data
    Senoussaoui, Mohammed El Amine
    Fofana, Issouf
    Brahami, Mostefa
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 170 - 175
  • [42] Transformer Fault Diagnosis Based on the analysis of dissolved gas in oil
    Sun, Jie
    Xing, Jiuxia
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 95 - 97
  • [43] EXPERIMENTAL METHODS AND APPLICATIONS OF DISSOLVED GAS DRIVING IN TIGHT OIL RESERVOIRS
    Wei, Yunyun
    Li, Xizhe
    Yang, Zhengming
    Liu, Xuewei
    SPECIAL TOPICS & REVIEWS IN POROUS MEDIA-AN INTERNATIONAL JOURNAL, 2016, 7 (04) : 377 - 384
  • [44] Dissolved gas amount influence on oil viscosity
    Mingulov, I. Sh.
    Valeev, M. D.
    Mukhametshin, V. V.
    Kuleshova, L. S.
    Mingulov, Sh. G.
    SOCAR PROCEEDINGS, 2023, 2023 (01): : 100 - 106
  • [45] Comparison of Dissolved Gas Interpretation Techniques in Mineral Oil Immersed Transformers
    Balivada, Santhosh Kumar
    Karmakar, Subrata
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 403 - 407
  • [46] Conventional methods of dissolved gas analysis using oil-immersed power transformer for fault diagnosis: A review
    Ali, Mohd Syukri
    Bakar, Ab Halim Abu
    Omar, Azimah
    Jaafar, Amirul Syafiq Abdul
    Mohamed, Siti Hajar
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [47] Applicability of semiconductor gas sensor for measurement of dissolved hydrogen gas in oil
    Sun, Jong-Ho
    Han, Sang-Bo
    Kang, Dong-Sik
    Kim, Kwang-Hwa
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 1257 - 1261
  • [48] Multi-Criterion Approach for Dissolved Gas Analysis of Transformer Oil
    Ranga, Chilaka
    Chandel, Ashwani Kumar
    2015 IEEE UP SECTION CONFERENCE ON ELECTRICAL COMPUTER AND ELECTRONICS (UPCON), 2015,
  • [49] Dissolved Gas Analysis Equipment for Online Monitoring of Transformer Oil: A Review
    Bustamante, Sergio
    Manana, Mario
    Arroyo, Alberto
    Castro, Pablo
    Laso, Alberto
    Martinez, Raquel
    SENSORS, 2019, 19 (19)
  • [50] Analysis of dissolved gas in transformer oil based on Laser Raman spectroscopy
    Chen, Weigen
    Zhao, Lizhi
    Peng, Shangyi
    Liu, Jun
    Zhou, Jingjing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (15): : 2485 - 2492