Comparison of Dissolved Gas-in-Oil Analysis Methods Using a Dissolved Gas-in-Oil Standard

被引:26
|
作者
Lelekakis, Nick [1 ]
Martin, Daniel [1 ]
Guo, Wenyu [1 ]
Wijaya, Jaury [1 ]
机构
[1] Monash Univ, TransformerLIFE Ctr, Ctr Power Transformer Monitoring Diagnost & Life, Clayton, Vic 3800, Australia
关键词
dissolved gas analysis; Shake Test; vacuum extraction; headspace;
D O I
10.1109/MEI.2011.6025366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved gas analysis (DGA) is routinely used to determine the concentrations of gases dissolved in the insulating oil of transformers. These concentrations are used to investigate and diagnose electrical or thermal faults [1]. Such faults cause the transformer oil, pressboard, and other insulating materials to decompose and generate gases, some of which dissolve in the oil. The results of DGA must be accurate if faults are to be diagnosed reliably. Commercial testing laboratories understandably prefer measurements that can be made easily and quickly. In this paper, DGA results from five independent testing laboratories are compared and discussed. A dissolved gas-in-oil standard with known dissolved gas concentrations was used as the basis of comparison. © 2006 IEEE.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [1] New techniques for dissolved gas-in-oil analysis
    Duval, M
    IEEE ELECTRICAL INSULATION MAGAZINE, 2003, 19 (02) : 6 - 15
  • [2] Application of quantum genetic ANNs in transformer dissolved gas-in-oil analysis
    Gao, Jun
    He, Junjia
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (30): : 121 - 127
  • [3] On-line monitoring of dissolved gas-in-oil with FTIR spectra
    Liu, XY
    Liu, YL
    Yue, L
    JOURNAL OF UNIVERSITY OF SCIENCE AND TECHNOLOGY BEIJING, 2003, 10 (04): : 65 - 68
  • [4] A New Fuzzy Logic Approach for Consistent Interpretation of Dissolved Gas-in-Oil Analysis
    Abu-Siada, A.
    Hmood, S.
    Islam, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2343 - 2349
  • [5] Artificial intelligence in OLTC fault diagnosis using dissolved gas-in-oil information
    Wang, ZY
    Liu, YL
    Griffin, PJ
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 2422 - 2427
  • [6] Dissolved Gas-in-Oil Analysis in Transformers Based on Near-Infrared Photoacoustic Spectroscopy
    Xuefeng Mao
    Xinlei Zhou
    Liang Zhai
    Qingxu Yu
    International Journal of Thermophysics, 2015, 36 : 940 - 946
  • [7] A new fuzzy logic approach to identify power transformer criticality using dissolved gas-in-oil analysis
    Abu-Siada, A.
    Hmood, S.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 67 : 401 - 408
  • [8] Dissolved Gas-in-Oil Analysis in Transformers Based on Near-Infrared Photoacoustic Spectroscopy
    Mao, Xuefeng
    Zhou, Xinlei
    Zhai, Liang
    Yu, Qingxu
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (5-6) : 940 - 946
  • [9] Application of RPROP ANN based fault diagnosis model for transformer dissolved gas-in-oil analysis
    Zhang, Jianguang
    Zhou, Hao
    Sheng, Ye
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2004, 28 (14): : 63 - 66
  • [10] Fuzzy Logic Approach for Power Transformer Asset Management Based on Dissolved Gas-in-Oil Analysis
    Abu-Siada, Ahmed
    Hmood, Sdood
    2013 PROGNOSTICS AND HEALTH MANAGEMENT CONFERENCE (PHM), 2013, 33 : 997 - 1002