Electroencephalogram variability analysis for monitoring depth of anesthesia

被引:8
|
作者
Chen, Yi-Feng [1 ,5 ]
Fan, Shou-Zen [2 ]
Abbod, Maysam F. [3 ]
Shieh, Jiann-Shing [4 ]
Zhang, Mingming [5 ]
机构
[1] Southern Univ Sci & Technol, Acad Adv Interdisciplinary Studies, Shenzhen 518055, Guangdong, Peoples R China
[2] Natl Taiwan Univ, Coll Med, Dept Anesthesiol, Taipei 100, Taiwan
[3] Brunel Univ London, Coll Engn Design & Phys Sci, Uxbridge UB8 3PH, Middx, England
[4] Yuan Ze Univ, Dept Mech Engn, Taoyuan 32003, Taiwan
[5] Southern Univ Sci & Technol, Dept Biomed Engn, Shenzhen Key Lab Smart Healthcare Engn, Shenzhen 518055, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
depth of anesthesia; electroencephalogram; general anesthesia; variability analysis; DETRENDED FLUCTUATION ANALYSIS; EMPIRICAL MODE DECOMPOSITION; BISPECTRAL INDEX; APPROXIMATE ENTROPY; EEG; SIGNAL; SEVOFLURANE; FREQUENCY; KETAMINE;
D O I
10.1088/1741-2552/ac3316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In this paper, a new approach of extracting and measuring the variability in electroencephalogram (EEG) was proposed to assess the depth of anesthesia (DOA) under general anesthesia. Approach. The EEG variability (EEGV) was extracted as a fluctuation in time interval that occurs between two local maxima of EEG. Eight parameters related to EEGV were measured in time and frequency domains, and compared with state-of-the-art DOA estimation parameters, including sample entropy, permutation entropy, median frequency and spectral edge frequency of EEG. The area under the receiver-operator characteristics curve (AUC) and Pearson correlation coefficient were used to validate its performance on 56 patients. Main results. Our proposed EEGV-derived parameters yield significant difference for discriminating between awake and anesthesia stages at a significance level of 0.05, as well as improvement in AUC and correlation coefficient on average, which surpasses the conventional features of EEG in detection accuracy of unconscious state and tracking the level of consciousness. Significance. To sum up, EEGV analysis provides a new perspective in quantifying EEG and corresponding parameters are powerful and promising for monitoring DOA under clinical situations.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Monitoring the depth of anesthesia with a BIS monitor
    Petrun, Andreja Moeller
    Kamenik, Mirt
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2010, 79 (01): : 43 - 47
  • [22] Monitoring the Depth of Anesthesia Using Electroencephalography
    Brook, Karolina
    Ferraton, Michael
    Dreher, Luke
    Lambert, Donald H.
    Feldman, Jeffrey M.
    Connor, Christopher W.
    A & A PRACTICE, 2025, 19 (01)
  • [23] COMPUTERIZED MONITORING OF DEPTH OF ANESTHESIA WITH ISOFLURANE
    THOMSEN, CE
    CHRISTENSEN, KN
    ROSENFALCK, A
    BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 (01) : 36 - 43
  • [24] CONTINUOUS ELECTROMYOGRAPHY FOR MONITORING DEPTH OF ANESTHESIA
    CHANG, TL
    DWORSKY, WA
    WHITE, PF
    ANESTHESIA AND ANALGESIA, 1988, 67 (06): : 521 - 525
  • [25] Depth of anesthesia and bispectral index monitoring
    Kissin, I
    ANESTHESIA AND ANALGESIA, 2000, 90 (05): : 1114 - 1117
  • [26] Depth of anesthesia monitoring techniques: An overview
    Stanski, DR
    ANESTHESIA FOR THE NEW MILLENNIUM: MODERN ANESTHETIC CLINICAL PHARMACOLOGY, 1999, 34 : 85 - 89
  • [27] Monitoring the depth of anesthesia: the quest for the Grail
    Molliex, S
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2001, 20 (09): : 743 - +
  • [28] Biomedical application of wavelets: Analysis of electroencephalograph signals for monitoring depth of anesthesia
    Abbate, A
    Nayak, A
    Koay, J
    Roy, RJ
    Das, P
    WAVELET APPLICATIONS III, 1996, 2762 : 412 - 423
  • [29] Electroencephalogram monitoring during anesthesia and critical care: a guide for the clinician
    Nitin Manohara
    Alessandra Ferrari
    Adam Greenblatt
    Andrea Berardino
    Cristina Peixoto
    Flávia Duarte
    Zahra Moyiaeri
    Chiara Robba
    Fabio A Nascimento
    Matthias Kreuzer
    Susana Vacas
    Francisco A. Lobo
    Journal of Clinical Monitoring and Computing, 2025, 39 (2) : 315 - 348
  • [30] Effects of detrending for analysis of heart rate variability and applications to the estimation of depth of anesthesia
    Yoo, CS
    Yi, SH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 44 (03) : 561 - 568