ECHO test Selection of Ultrasonic Transducer Focal and Water Path Lengths for Immersion Pulse-echo Testing of Cylinders

被引:0
|
作者
Beck, K. H. [1 ]
机构
[1] Tac Tech Instrument Corp, Trenton, NJ 08628 USA
关键词
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The selection procedure discussed in this paper applies to immersion pulse echo testing of cylinders This includes any arrangement of a single transducer coupled to the surface of a cylinder through a column of couplant usually water Therefore, water path indicates the distance between transducer face and cylinder surface Interference may be caused by the signal produced by the second return of the initial pulse striking and being reflected from the surface of the tested material If this signal occurs before a signal return from a target at any depth in the material it precludes the proper search for signals beyond the point where the interfering signal occurs The treatment presented in this paper shows how to select a transducer focal length, and the water path length to be employed in order to avoid such potential interference
引用
收藏
页码:1329 / 1331
页数:3
相关论文
共 50 条
  • [41] DETECTION OF CRACKS IN SKIRT ATTACHMENT WELDS OF A ROCKET MOTOR CASE USING CONTACT PULSE-ECHO ULTRASONIC TEST METHODS
    MAGNUSSO.EJ
    BURTON, LM
    MATERIALS EVALUATION, 1969, 27 (02) : A20 - &
  • [42] Modeling Flaw Pulse-Echo Signals in Cylindrical Components Using an Ultrasonic Line-Focused Transducer with Consideration of Wave Mode Conversion
    Wang, Weixin
    Liu, Xiling
    Li, Xiongbing
    Xu, Gang
    Zhang, Shuzeng
    SENSORS, 2019, 19 (12)
  • [43] Low frequency ultrasonic pulse-echo datasets for object detection and thickness measurement in concrete specimens as testing tasks in civil engineering
    Maack, Stefan
    Kuettenbaum, Stefan
    Buehling, Benjamin
    Borchardt-Giers, Kerstin
    Assmann, Norman
    Niederleithinger, Ernst
    DATA IN BRIEF, 2023, 48
  • [44] Comparative Study on Ultrasonic C-Scan Imaging of Composite Lap Joints Using Piezoelectric Transducer: Pulse-Echo and Pitch-Catch Configurations
    Barzegar, Mohsen
    Pasadas, Dario J.
    Ribeiro, Artur L.
    Ramos, Helena G.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 10
  • [45] Korea Air Force Standard NDE Coupon Test of Full-Field Pulse-Echo Laser Ultrasonic Propagation Imaging System
    Hong, Seung-Chan
    Lee, Jung-Ryul
    Park, Jongwoon
    2015 IEEE SENSORS, 2015, : 25 - 28
  • [46] Artifact reduction in non-destructive testing by means of complementary data fusion of x-ray computed tomography and ultrasonic pulse-echo testing
    Schrapp, Michael
    Scharrer, Thomas
    Goldammer, Matthias
    Rupitsch, Stefan J.
    Sutor, Alexander
    Ermert, Helmut
    Lerch, Reinhard
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (12)
  • [47] Development of an Inline Water Mains Inspection Technology Detection of acidic deterioration in cement-based water pipes with ultrasonic pulse-echo technique
    Delgadillo, Hector Hernandez
    Loendersloot, Richard
    Akkerman, Remko
    Yntema, Doekle
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [48] Critical evaluation of pulse-echo ultrasonic test method for the determination of setting and mechanical properties of acrylic bone cement: Influence of mixing technique
    Hagan, Christopher P.
    Orr, John F.
    Mitchell, Christina A.
    Dunne, Nicholas J.
    ULTRASONICS, 2015, 56 : 279 - 286
  • [49] Influence of water content on ultrasonic pulse-echo measurements through high volume fly ash cement paste-physicomechanical characterization
    Aydin, Ertug
    Doven, Ata G.
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2006, 17 (04) : 177 - 189
  • [50] A study on 3D scan-based robot arm control approach for pulse-echo laser ultrasonic testing of curved composite structures
    Ma, King Sum
    Lee, Kyu-Jin
    Lee, Jung-Ryul
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (04)