Operational experience with the CDF Run 2 silicon tracker

被引:6
|
作者
Brau, B [1 ]
机构
[1] Univ Calif Santa Barbara, Dept Phys, Santa Barbara, CA 93106 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 541卷 / 1-2期
关键词
CDF; silicon; Run; 2; Layer; 00; ISL; SVXII;
D O I
10.1016/j.nima.2005.01.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Run 2 CDF silicon detector plays an important role in heavy flavor tagging and enables a significant increase in acceptance. I will describe our experience operating the detector during Run 2. I will cover several failure modes which have emerged and discuss the performance improvements from a novel layer mounted on the beampipe. Since the beginning of Run 2, the Tevatron at Fermilab has delivered almost 0.5 fb(-1) integrated luminosity to CDF. The CDF silicon has now been exposed to enough radiation that aging can be measured. I will present studies of charge collection and noise versus applied bias voltage at several different integrated luminosities. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [41] The CDF Run II silicon detector: Aging studies
    Garcia, Jose E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 92 - 95
  • [42] Status and performance of the CDF Run II silicon detector
    Wallny, RS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 56 - 59
  • [43] DZero silicon tracker for Run IIb at the Tevatron
    Nomerotski, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 295 - 296
  • [44] Radiation Life of the CDF Run II Silicon Detector
    Redondo, Ignacio
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 503 - 506
  • [45] The CDF RUN II Silicon Detector: Aging Studies
    Redondo Fernandez, Ignacio
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 451 - 455
  • [46] CDF run IIb silicon: The new innermost layer
    Merkel, P
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1128 - 1132
  • [47] CDF run IIb silicon: Stave design and testing
    Lu, RS
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1123 - 1127
  • [48] Status and performance of the CDF Run II silicon detector
    Wallny, RS
    ICHEP 2005: PROCEEDINGS OF THE 32ND INTERNATIONAL CONFERENCE HIGH ENERGY PHYSICS VOLS 1 AND 2, 2005, : 953 - 955
  • [49] Radiation experience with the CDF silicon detectors
    Husemann, Ulrich
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (01): : 65 - 68
  • [50] The LHCb Silicon Tracker, first operational results
    Esperante, Daniel
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,