Full-Stokes Retrieving and Configuration Optimization in a Time-Integration Imaging Polarimeter

被引:5
|
作者
Gu, Naiting [1 ,2 ,3 ]
Lian, Bowen [1 ,2 ,3 ]
Xiao, Yawei [1 ,2 ]
Huang, Linhai [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
[2] Chinese Acad Sci, Key Lab Adapt Opt, Chengdu 610209, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
imaging polarimeter; full-Stokes vector retrieving; time integration; configuration optimization; POLARIZATION ANALYSIS; NOISE; MINIMIZATION; DIVISION; RETARDER;
D O I
10.3390/s22134733
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A time-integration imaging polarimeter with continuous rotating retarder is presented, and its full-Stokes retrieving and configuration optimization are also demonstrated. The mathematical expression between the full-Stokes vector and the time-integration light intensities is derived. As a result, the state of polarization of incident light can be retrieved by only one matrix calculation. However, the modulation matrix deviates from the initial well-conditioned status due to time integration. Thus, we re-optimize the nominal angles for the special retardance of 132 degrees and 90 degrees with an exposure angle of 30 degrees, which results in a reduction of 31.8% and 16.8% of condition numbers comparing to the original configuration, respectively. We also give global optimization results under different exposure angles and retardance of retarder; as a result, the 137.7 degrees of retardance achieves a minimal condition number of 2.0, which indicates a well-conditioned polarimeter configuration. Besides, the frame-by-frame algorithm ensures the dynamic performance of the presented polarimeter. For a general brushless DC motor with a rotating speed of over 2000 rounds per minute, the speed of polarization imaging will achieve up to 270 frames per second. High precision and excellent dynamic performance, together with features of compactness, simplicity, and low cost, may give this traditional imaging polarimeter new life and attractive prospects.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Coded aperture full-stokes imaging spectropolarimeter
    Chen, Zeyu
    Zhang, Chunmin
    Mu, Tingkui
    Wang, Yanqiang
    He, Yifan
    Yan, Tingyu
    Chen, Zhengyi
    OPTICS AND LASER TECHNOLOGY, 2022, 150
  • [22] An on-chip full-Stokes polarimeter based on optoelectronic polarization eigenvectors
    Deng, Jie
    Shi, Mengdie
    Liu, Xingsi
    Zhou, Jing
    Qin, Xinyue
    Wang, Ruowen
    Zhen, Yuran
    Dai, Xu
    Chen, Yinzhu
    Wei, Jingxuan
    Ni, Zhenhua
    Gao, Weibo
    Qiu, Cheng-Wei
    Chen, Xiaoshuang
    NATURE ELECTRONICS, 2024, 7 (11): : 1004 - 1014
  • [23] Demonstration of a snapshot full-Stokes division-of-aperture imaging polarimeter using Wollaston prism array
    Mu, Tingkui
    Zhang, Chunmin
    Liang, Rongguang
    JOURNAL OF OPTICS, 2015, 17 (12)
  • [24] Full-Stokes Polarimeter Based on Chiral Perovskites with Chirality and Large Optical Anisotropy
    Ma, Jiaqi
    Fang, Chen
    Liang, Lihan
    Wang, Haizhen
    Li, Dehui
    SMALL, 2021, 17 (47)
  • [25] Homemade open-source full-Stokes polarimeter based on division of amplitude
    Del Rio-lima, A.
    Gutierrez-valdes, A.
    Mojica-casique, C.
    Ballesteros-flores, F.
    Villanueva-reyes, I. A.
    Colin-rodriguez, R.
    Gardea-flores, C. A.
    Poveda-cuevas, F. J.
    Seman, J. A.
    APPLIED OPTICS, 2024, 63 (27) : 7177 - 7187
  • [26] Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics and architectural comparison of polarimeter techniques
    Yang, Ruonan
    Sen, Pratik
    O'Connor, B. T.
    Kudenov, M. W.
    POLARIZATION SCIENCE AND REMOTE SENSING VIII, 2017, 10407
  • [27] The design and implementation of the full-Stokes imaging spectropolarimeter
    Zhou, Jiankang
    Ji, Yiqun
    Chen, Xinhua
    Chen, Yuheng
    Ma, Suodong
    Shen, Weimin
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [28] Optimal configurations of full-Stokes polarimeter with immunity to both Poisson and Gaussian noise
    Mu, Tingkui
    Chen, Zeyu
    Zhang, Chunmin
    Liang, Rongguang
    JOURNAL OF OPTICS, 2016, 18 (05)
  • [29] Numeric Study of Novel Compact Polarimeter for Full-Stokes Polarization Imaging Without Micro-Polarizer Array
    Gu, Naiting
    Xu, Duo
    Huang, Linhai
    Rao, Changhui
    IEEE ACCESS, 2020, 8 : 53456 - 53462
  • [30] Birefringence compensation for single-shot 3D profilometry using a full-Stokes imaging polarimeter
    Yuuki Maeda
    Shuhei Shibata
    Nathan Hagen
    Yukitoshi Otani
    Optical Review, 2021, 28 : 425 - 433