Traveling wave protection based on asynchronously sampled time difference of arrival of modulus traveling waves in per unit line length

被引:6
|
作者
Liang Rui [1 ,2 ]
Wang Zheng [1 ,2 ]
Peng Nan [1 ,2 ]
Zare, Firuz [3 ]
Liu Xiaowen [4 ]
Liu Chenglei [5 ]
机构
[1] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] Jiangsu Prov Lab Elect & Automat Engn Coal Min, Xuzhou 221116, Jiangsu, Peoples R China
[3] Univ Queensland, Brisbane, Qld 4072, Australia
[4] China Univ Min & Technol, Sch Informat & Control Engn, Xuzhou 221116, Jiangsu, Peoples R China
[5] State Grid Jiangsu Elect Power Maintenance Branch, Xuzhou Div, Xuzhou 221000, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Traveling wave protection; Transmission networks; Modulus traveling waves; Time difference of arrival; PARALLEL TRANSMISSION-LINES; HIGH-SPEED PROTECTION; DISTANCE PROTECTION; SCHEME; TRANSIENTS; ALGORITHM;
D O I
10.1016/j.epsr.2018.08.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional traveling wave protection schemes are susceptible to many factors such as network topology change, environment interference and inaccurate identification of wave fronts, which may lead to mal-operation of protection. In addition, most traveling wave protection schemes need accurate synchronous measurement which adds to the implementation cost. This paper proposes a traveling wave protection for high voltage power grids based on the time difference of arrival (TDOA) of zero-mode and aerial-mode traveling wave. First, the time difference of arrival of the modulus voltage traveling waves (MVTWs) asynchronously sampled at each bus is captured. With the minimum TDOA, the key bus and fault area can be firstly determined. Then, the TDOA of the line in per unit length is defined as the ratio between the difference of the TDOAs at both terminal buses and line length. Finally, as for one case that key bus connects with no other bus, the line corresponding to the minimum TDOA of all the lines in the fault area is determined as the fault line. As for the other case, the calculated line length should be compared with the actual one to detect the fault line. PSCAD/EMTDC is used to conduct fault simulations and the calculation results verify that the proposed scheme is not affected by fault resistances, inception angles and distances. In addition, the operation time of the scheme does not exceed 20 ms, which makes it applicable for actual power grid protection.
引用
收藏
页码:250 / 258
页数:9
相关论文
共 50 条
  • [31] A Novel Scheme of HVDC Transmission Line Voltage Traveling Wave Protection Based on Wavelet Transform
    Li Zhen-qiang
    Lv Yan-ping
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 163 - +
  • [32] Traveling Wave Characteristics Based Pilot Protection Scheme for Hybrid Cascaded HVDC Transmission Line
    Dalin Mu
    Sheng Lin
    Xiaopeng Li
    Journal of Modern Power Systems and Clean Energy, 2024, 12 (03) : 971 - 980
  • [33] A novel scheme of HVDC transmission line voltage traveling wave protection based on wavelet transform
    Li, Zhen-Qiang
    Lu, Gai-Feng
    Lü, Yan-Ping
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (13): : 40 - 45
  • [34] High-Frequency-Based Transmission Line Percentage Differential Protection With Traveling Wave Alignment
    Prado, Igor F.
    Costa, Flavio B.
    Silva, Kleber M.
    Medeiros, Rodrigo P.
    Mork, Bruce A.
    IEEE ACCESS, 2024, 12 : 129404 - 129416
  • [35] A real-time DWT and traveling waves-based multi-functional scheme for transmission line protection reinforcement
    Jnaneswar, K.
    Mallikarjuna, B.
    Devaraj, S.
    Roy, Diptendu Sinha
    Reddy, M. Jaya Bharata
    Mohanta, D. K.
    ELECTRICAL ENGINEERING, 2021, 103 (02) : 965 - 981
  • [36] A real-time DWT and traveling waves-based multi-functional scheme for transmission line protection reinforcement
    K. Jnaneswar
    B. Mallikarjuna
    S. Devaraj
    Diptendu Sinha Roy
    M. Jaya Bharata Reddy
    D. K. Mohanta
    Electrical Engineering, 2021, 103 : 965 - 981
  • [37] A new fault location method avoiding wave speed and based on traveling waves for EHV transmission line
    Zhang Feng
    Liang Jun
    Zhang Li
    Yun Zhihao
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1753 - 1757
  • [38] Single-Ended Protection for Flexible DC Transmission Line Based on Curvature of Initial Traveling Wave
    Dai Z.
    Liu Z.
    Liu X.
    Yan S.
    Jiang Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (09): : 1831 - 1841
  • [39] Line Pilot Protection of Flexible DC Grid Based on Voltage Traveling-wave Refraction Coefficient
    Dai Z.
    Qin H.
    Qiu H.
    Wang X.
    Guo Y.
    Qiu X.
    Dianwang Jishu/Power System Technology, 2022, 46 (12): : 4676 - 4689
  • [40] Longitudinal protection method based on reverse traveling wave and signal processing for UHVDC power transmission line
    Wang Y.
    Fan Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (03): : 114 - 121