Adaptive optofluidic lens(es) for switchable 2D and 3D imaging

被引:1
|
作者
Huang, Hanyang [1 ,2 ]
Wei, Kang [1 ]
Zhao, Yi [1 ,2 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech Engn, Columbus, OH 43210 USA
关键词
optofluidic lens; binocular; stereoscopic vision; depth perception; STEREOSCOPIC VISION;
D O I
10.1117/12.2211232
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The stereoscopic image is often captured using dual cameras arranged side-by-side and optical path switching systems such as two separate solid lenses or biprism/mirrors. The miniaturization of the overall size of current stereoscopic devices down to several millimeters is at a sacrifice of further device size shrinkage. The limited light entry worsens the final image resolution and brightness. It is known that optofluidics offer good re-configurability for imaging systems. Leveraging this technique, we report a reconfigurable optofluidic system whose optical layout can be swapped between a singlet lens with 10 mm in diameter and a pair of binocular lenses with each lens of 3 mm in diameter for switchable two-dimensional (2D) and three-dimensional (3D) imaging. The singlet and the binoculars share the same optical path and the same imaging sensor. The singlet acquires a 3D image with better resolution and brightness, while the binoculars capture stereoscopic image pairs for 3D vision and depth perception. The focusing power tuning capability of the singlet and the binoculars enable image acquisition at varied object planes by adjusting the hydrostatic pressure across the lens membrane. The vari-focal singlet and binoculars thus work interchangeably and complementarily. The device is thus expected to have applications in robotic vision, stereoscopy, laparoendoscopy and miniaturized zoom lens system.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A 2D/3D switchable autostereoscopic display system, an acousto-optic lens approach
    Chen, I-Ju
    Tarn, Chen-Wen
    OPTIK, 2015, 126 (23): : 4061 - 4065
  • [22] Four-mode 2D/3D switchable display with a 1D/2D convertible liquid crystal lens array
    Chu, Fan
    Guo, Yu-Qiang
    Zhang, Yu-Xian
    Duan, Wei
    Zhang, Han-Le
    Tian, Li-Lan
    Li, Lei
    Wang, Qiong-Hua
    OPTICS EXPRESS, 2021, 29 (23) : 37464 - 37475
  • [23] 2D/3D mixed display based on integral imaging and a switchable diffuser element
    Ren, Hui
    Xing, Yan
    Zhang, Han-Le
    Li, Qiang
    Wang, Lei
    Deng, Huan
    Wang, Qiong-Hua
    APPLIED OPTICS, 2019, 58 (34) : G276 - G281
  • [24] Single frontal projection 2D/3D switchable display based on integral imaging
    Li, Qiang
    Zhong, Feiyan
    He, Wei
    Deng, Huan
    2021 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2021,
  • [25] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [26] Multi-View 2D/3D Switchable Display with Cylindrical Liquid Crystal Lens Array
    Chu, Fan
    Wang, Di
    Liu, Chao
    Li, Lei
    Wang, Qiong-Hua
    CRYSTALS, 2021, 11 (06):
  • [27] 2D/3D dual-image switchable display
    Kuo, Wei-Hung
    Chou, Weng-Bing
    Cheng, Tsung-Chin
    Yeh, Pi-Chun
    Jeng, Yue-Shin
    Hu, Chih-Jen
    Huang, Wei-Ming
    2008 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXIX, BOOKS I-III, 2008, 39 : 264 - 266
  • [28] 2D/3D switchable LCD monitor with chromatic separation
    Gaskevich, Evgeny B.
    STEREOSCOPIC DISPLAYS AND APPLICATIONS XXI, 2010, 7524
  • [29] 2D/3D registration with the CMA-ES method
    Gong, Ren Hui
    Abolmaesumi, Purang
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [30] Compressive Adaptive Beamforming in 2D and 3D Ultrafast Active Cavitation Imaging
    Bai, Chen
    Xu, Shanshan
    Jing, Bowen
    Yang, Miao
    Wan, Mingxi
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,