Self-occluding quad NaI directional gamma radiation detector for standoff radiation detection

被引:2
|
作者
Portnoy, David [1 ]
Mattson, John [1 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD 20723 USA
关键词
Radiation Detection; Directional Gamma Sensor; Standoff Radiation Detection;
D O I
10.1117/12.894017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently there is a significant amount of interest in standoff radiation detection. One of the biggest challenges is to separate small radiation signals from large varying background radiation. Many systems have been developed to address this problem that rely on coded-aperture and/or Compton imaging. These imaging systems tend to be large, heavy, complex, and therefore expensive. In this paper we report on the development of a self-occluding directional gamma radiation sensor that is relatively small (<40 kg), inexpensive, and simple in design. Laboratory and field measurements suggest that these sensors will work as well as the gamma imaging systems for many radiation detection applications at a fraction of the cost, weight, and complexity. An azimuth can be resolved with a standard deviation of 7 degrees in 10 seconds for a source yielding 45 CPS at the detector in a 300 CPS background radiation field. This paper describes the self-occluding quad NaI directional gamma radiation detector, the impact of gamma energy and distance on angular precision and accuracy, and potential applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Directional radiation detector
    Uher, J.
    Frojdh, C.
    Jakubek, J.
    Pospisil, S.
    Thungstrom, G.
    Vykydal, Z.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1162 - 1165
  • [2] CALCULATION OF RESPONSE OF NAI(T1) DETECTOR TO GAMMA-RADIATION
    BILBAO, J
    CASANOVA, J
    DEMIGUEL, A
    ANALES DE FISICA, 1973, 69 (7-9): : 279 - 286
  • [3] DIRECTIONAL DETECTOR OF GRAVITATIONAL RADIATION
    WALKER, EH
    FRYE, G
    FENNELLY, AJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 554 - 554
  • [4] Directional Geiger-Muller detector with improved response to gamma radiation
    Habrman, P.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (09)
  • [5] Radioactive source strength effect on gamma radiation monitoring with a NaI (Tl) scintillation detector
    Yeboah, E.
    Yakovlev, G. A.
    Smirnov, S. V.
    Yakovleva, V. S.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [6] GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR
    Dinh Tien Hung
    Cao Van Hiep
    Pham Dinh Khang
    Nguyen Xuan Hai
    Nguyen Ngoc Anh
    Dinh, D. A.
    Nhan Hao, T., V
    Pham, V
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (01) : 48 - 55
  • [7] ABSORPTION OF GAMMA RADIATION IN NAI WELL CRYSTALS
    WACHTER, MH
    ELLETT, WH
    BROWNELL, GL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (06): : 626 - 630
  • [8] A large dynamic range gamma radiation detector insensitive to neutron radiation
    Hu, MC
    Ye, WY
    Peng, TP
    Zhou, DZ
    Wang, ZT
    Zhang, JH
    Hu, QY
    Yang, HQ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (04): : 354 - 358
  • [9] IMPROVEMENT OF SEMICONDUCTOR RADIATION DETECTOR SPECIFICATIONS BY INFRARED AND GAMMA-RADIATION
    SCHROEDER, ANF
    CASELLI, E
    NIMTZ, G
    NUCLEAR INSTRUMENTS & METHODS, 1979, 159 (01): : 93 - 97
  • [10] 2 GE(LI)-6 NAI(TL) DETECTOR SYSTEM FOR GAMMA-GAMMA DIRECTIONAL CORRELATION STUDIES
    ERIKSSON, L
    GIDEFELD.L
    NUCLEAR INSTRUMENTS & METHODS, 1974, 114 (01): : 127 - 129