Acoustic Emission from Elevator Wire Ropes During Tensile Testing

被引:1
|
作者
Bai, Wenjie [1 ]
Chai, Mengyu [1 ]
Li, Lichan [1 ]
Li, Yongquan [1 ]
Duan, Quan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian 710049, Peoples R China
来源
关键词
D O I
10.1007/978-1-4939-1239-1_20
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The acoustic emission (AE) technique was used to monitor the tensile testing process for two kinds of elevator wire ropes in our work. The AE signals from wire breaks were obtained and analyzed by AE parameters and waveforms. The results showed that AE technique can be a useful tool to monitor wire break phenomenon of wire ropes and effectively capture information of wire break signal. The relationship between AE signal characteristics and wire breaks is investigated and it is found that the most effective acoustic signal discriminators are amplitude and absolute energy. Moreover, the wire break signal of two kinds of ropes is a type of burst signal and it is believed that the waveform and spectrum can be applied to analyze the AE wire break signals.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 50 条
  • [21] Coupling Behavior of Wire Ropes Subjected to Tensile Impulses
    Yen, J. Y. R.
    Chen, C. H.
    Chung, S. C.
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2009, 135 (08): : 796 - 801
  • [22] Tensile strength of steel ropes of diamond wire saws
    Dunda, Siniša
    Kujundzić, Trpimir
    2001, University of Zagreb, Faculty of Mining, Geology and Petroleum Engineering
  • [23] Life estimation of elevator wire ropes using accelerated degradation test data
    Kim S.H.
    Kim S.B.
    Kim S.H.
    Ham S.H.
    Transactions of the Korean Society of Mechanical Engineers, A, 2017, 41 (10) : 997 - 1004
  • [24] Research on Safety Testing for Steel Wire Ropes
    Zhang Xiaochun
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION AND INSTRUMENTATION, VOL 4, 2008, : 2186 - 2189
  • [25] METHOD OF TESTING NONROTATING WIRE HOISTING ROPES
    GLUSHKO, MF
    INDUSTRIAL LABORATORY, 1958, 24 (02): : 225 - 227
  • [26] Acoustic emission testing in wires from the tensile armour of flexible risers under load
    Jacques, R. C.
    Flores, J. V.
    Strohaecker, T. R.
    Reguly, A.
    INSIGHT, 2009, 51 (09) : 504 - +
  • [27] Electromagnetic testing of wire ropes - New developments
    Geller, LB
    Leung, K
    Udd, JE
    Kitzinger, F
    CIM BULLETIN, 2003, 96 (1074): : 65 - 71
  • [28] In-situ testing of steel wire ropes
    Zawada, Kazimierz
    Wire Industry, 1994, 61 (721): : 43 - 45
  • [29] Electromagnetic Testing Method of Wire Ropes.
    Meyer, Urs Balthasar
    VDI-Z, 1974, 116 (11): : 919 - 926
  • [30] Testing methods of steel wire ropes at the anchor
    Kresak, Jozef
    Kropuch, Stanislav
    Peterka, Pavel
    ACTA MONTANISTICA SLOVACA, 2012, 17 (03) : 174 - 178