Reading protocol for dynamic contrast-enhanced MR images of the breast: Sensitivity and specificity analysis

被引:87
|
作者
Warren, RML
Pointon, L
Thompson, D
Hoff, R
Gilbert, FJ
Padhani, A
Easton, D
Lakhani, SR
Leach, MO
机构
[1] Royal Marsden Hosp, Study Coordinating Off, Sect Magnet Resonance, Inst Canc Res, Sutton SM2 5PT, Surrey, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
[3] Univ Aberdeen, Dept Radiol, Aberdeen AB9 1FX, Scotland
[4] CR UK Genet Epidemiol Unit, Cambridge, England
[5] Royal Marsden Hosp, Inst Canc Res, Breakthrough Breast Canc Res Ctr, London SW3 6JJ, England
[6] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
关键词
D O I
10.1148/radiol.2363040735
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively determine sensitivity and specificity of breast magnetic resonance (MR) imaging in a screening and symptomatic population by using independent double reading, with histologic or cytologic results or a minimum 18-month follow-up as the standard. MATERIALS AND METHODS: Informed consent and ethical approval were obtained. Reader performance was analyzed in 44 radiologists at 18 centers from 1541 examinations, including 1441 screening examinations in 638 high-risk women aged 24-51 years (mean, 40.5 years) and 100 examinations in symptomatic women aged 23-81 years (mean, 49.2 years). A screening protocol of dynamic T1-weighted three-dimensional imaging and 0.2 mmol/kg gadolinium-based intravenous contrast agent was used. Logistic and Poisson regressions were used to analyze reader performance in relation to experience. Correlation between readers was determined with K statistics. Sensitivity and specificity were analyzed according to reader, field strength, machine type, and histologic results. RESULTS: The proportion of studies with lesions analyzed reduced significantly with reader experience (odds ratio, 0.84 per 6 months; P < .001), and number of regions per lesion analyzed also diminished (incidence rate ratio, 0.98 per 6 months; P = .047). The two readers for each study agreed 87% of the time, with a moderately good K statistic of 0.52 (95% confidence interval [CI]: 0.45, 0.58). By taking the reading with the highest score (most likely to be malignant) from each double-read study, sensitivity was 91% (95% CI: 83%, 96%) and specificity was 81% (95% CI: 79%, 83%). Single readings had 7% lower sensitivity (95% CI: 4%, 11%) and 7% higher specificity (95% CI: 6%, 7%). Sensitivity did not differ between MR imager manufacturers or between 1.0- and 1.5-T field strength, but there were significant differences in specificity for machine type (P = .001) and for field strength adjusted for manufacturer (P =.001). Specificity, but not sensitivity, was higher in women younger than 50 years (P = .02). CONCLUSION: Independent double reading by 44 radiologists blinded to mammography results showed sensitivity and specificity acceptable for screening; sensitivity was higher when two readings were used, at the cost of specificity. Interreader correlation was moderately good, and evidence of learning was seen. Equipment manufacturer, field strength, and age affected specificity but not sensitivity. (c) RSNA, 2005
引用
收藏
页码:779 / 788
页数:10
相关论文
共 50 条
  • [21] Breast cancer in dense breast: Detection with contrast-enhanced dynamic MR imaging
    Kawashima, H
    Matsui, O
    Suzuki, M
    Kadoya, M
    Tawara, M
    Nonomura, A
    Noguchi, M
    Takashima, T
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (03): : 233 - 243
  • [22] A technique for fully automated segmentation of breast tumors using dynamic contrast-enhanced MR images (WIP)
    Parakkal, R
    Burnside, B
    Kelcz, F
    Fain, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1368 - 1368
  • [23] Measuring sparse temporal-variation for accurate registration of dynamic contrast-enhanced breast MR images
    Zheng, Yuanjie
    Wei, Benzheng
    Liu, Hui
    Xiao, Rui
    Gee, James C.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 46 : 73 - 80
  • [24] Non-mass-like enhancement on contrast-enhanced breast MR imaging: Lesion characterization using combination of dynamic contrast-enhanced and diffusion-weighted MR images
    Yabuuchi, Hidetake
    Matsuo, Yoshio
    Kamitani, Takeshi
    Setoguchi, Taro
    Okafuji, Takashi
    Soeda, Hiroyasu
    Sakai, Shuji
    Hatakenaka, Masamitsu
    Kubo, Makoto
    Tokunaga, Eriko
    Yamamoto, Hidetaka
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (01) : E126 - E132
  • [25] Anatomical landmark localization in breast dynamic contrast-enhanced MR imaging
    Yin, X. X.
    Ng, B. W. -H.
    Yang, Q.
    Pitman, A.
    Ramamohanarao, K.
    Abbott, D.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (01) : 91 - 101
  • [26] Anatomical landmark localization in breast dynamic contrast-enhanced MR imaging
    X. X. Yin
    B. W.-H. Ng
    Q. Yang
    A. Pitman
    K. Ramamohanarao
    D. Abbott
    Medical & Biological Engineering & Computing, 2012, 50 : 91 - 101
  • [27] Dynamic contrast-enhanced breast MR imaging in men: Preliminary results
    Morakkabati-Spitz, N
    Schild, HH
    Leutner, CC
    von Falkenhausen, M
    Lutterbey, G
    Kuhl, CK
    RADIOLOGY, 2006, 238 (02) : 438 - 445
  • [28] Quantitative Analysis of Dynamic Contrast-Enhanced MR Images Based on Bayesian P-Splines
    Schmid, Volker J.
    Whitcher, Brandon
    Padhani, Anwar R.
    Yang, Guang-Zhong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (06) : 789 - 798
  • [29] Brain Gliomas: Multicenter Standardized Assessment of Dynamic Contrast-enhanced and Dynamic Susceptibility Contrast MR Images
    Anzalone, Nicoletta
    Castellano, Antonella
    Cadioli, Marcello
    Conte, Gian Marco
    Cuccarini, Valeria
    Bizzi, Alberto
    Grimaldi, Marco
    Costa, Antonella
    Grillea, Giovanni
    Vitali, Paolo
    Aquino, Domenico
    Terreni, Maria Rosa
    Torri, Valter
    Erickson, Bradley J.
    Caulo, Massimo
    RADIOLOGY, 2018, 287 (03) : 933 - 943
  • [30] Myocardial perfusion by contrast-enhanced echocardiography and dynamic contrast-enhanced MR imaging
    Lombardi, M
    Rovai, D
    Rinck, PA
    LAbbate, A
    ACTA RADIOLOGICA, 1997, 38 : 79 - 84