Performance Evaluation of PV Interfaced Z-Source-Network-Based Shunt Active Power Filter

被引:1
|
作者
Sellakumar, S. [1 ]
Vijayakumar, M. [2 ]
机构
[1] Jeppiaar Engn Coll, Dept Elect & Elect Engn, Madras 600119, Tamil Nadu, India
[2] JNTU Ananthapur Univ, Anantapur 515002, Andhra Pradesh, India
关键词
photovoltaic system; second-order generalized integrator; shunt active power filter; voltage source inverter; total harmonic distortion; Z-SOURCE INVERTER; QUALITY CONDITIONER; ENERGY-STORAGE; REACTIVE POWER; VOLTAGE; COMPENSATION; DESIGN; BOOST; TIME;
D O I
10.1520/JTE20160260
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, a photovoltaic supported Z-source-inverter (ZSI)-based shunt active power filter (SAPF) is proposed for power-quality improvement. The topology has a voltage source inverter (VSI), which is connected in parallel with the point of common coupling (PCC), and is assisted by an impedance network. The Z-source network is really a distinct impedance network to facilitate interconnection between the photovoltaic (PV) power-generating system and VSI. The key features of ZSI can boost up the changeable dc voltage into any specified AC output voltage, decrease the components required, and mitigate harmonic content. The compensation capability of the SAPF mainly depends on the control scheme utilized to reference current generations. In addition, the control scheme decides a number of sensor essential and measurement practices; thus, it also estimates the cost of the topology. In this proposed system, second-order generalized integrator (SOGI) is employed to extract the reference current of SAPF. The SOGI-based control scheme uses only the measurement of the converter, and load current as the feedback signals therefore does not need voltage measurement and sensors. The proposed SAPF topology utilizes an alternative energy source having an energy storage unit to compensate the long-term current disturbances and voltage interruption and mete out the active power requirement of the utility grid. The PV-supported ZSI-based SAPF tested with various kinds of loads can examine the performance of the system under steady and dynamic state conditions. To verify the effectiveness of the proposed control scheme and PV-supported SAPF topology, the simulation and experimental results are presented.
引用
收藏
页码:2151 / 2165
页数:15
相关论文
共 50 条
  • [41] Modelling and Analysis of PV-Based Shunt Active Filter with BESS and Conservative Power Theory for Enhancing Power Quality
    Ramalingam, Gomathi
    Choudhary, Ajay Kumar
    Mikkili, Suresh
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2019, 20 (06):
  • [42] Evaluation of a Shunt Active Power Filter with Energy Backup Capability
    Exposto, Bruno
    Pinto, J. G.
    Goncalves, Henrique
    Monteiro, Vitor
    Pedrosa, Delfim
    Couto, Carlos
    Afonso, Joao L.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5963 - 5968
  • [43] Realization of a Shunt Active Power Filter with Improved Dynamic Performance
    Sozanski, Krzysztof Piotr
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (07): : 163 - 167
  • [44] Performance of Shunt Active Power Filter Under Sensor Failure
    Sharma, Shivangni
    Verma, Vimlesh
    2017 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (IEEE WIECON-ECE 2017), 2017, : 165 - 168
  • [45] Shunt Active Power Filter Based on Savitzky-Golay Filter: Pragmatic Modelling and Performance Validation
    Hasan, Kamrul
    Othman, Muhammad Murtadha
    Meraj, Sheikh Tanzim
    Mekhilef, Saad
    Abidin, Ahmad Farid Bin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (07) : 8838 - 8850
  • [46] Implementation of shunt active power filter using source voltage and source current detection
    Khruathep, Udom
    Premrudeepreechacharn, Suttichai
    Kumsuwan, Yuttana
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 2346 - +
  • [47] Performance Analysis of Shunt Active Power Filter based on GSA tuned PI Controller
    Agrawal, Seema
    Sen, Brijesh Kumar
    Palwalia, D. K.
    2017 IEEE INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION, INSTRUMENTATION AND CONTROL (ICICIC), 2017,
  • [48] Performance Evaluation of LLCL Filter for Active Power Filter
    Buyuk, Mehmet
    Inci, Mustafa
    Tumay, Mehmet
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [49] A MULTI-OBJECTIVE OPTIMIZATION FOR PERFORMANCE IMPROVEMENT OF THE Z-SOURCE ACTIVE POWER FILTER
    Hosseini, Seyed Mohsen
    Beromi, Yousef Alinejad
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2016, 67 (05): : 358 - 364
  • [50] Performance Evaluation of Shunt Active Power filter Control strategies under Different Supply Conditions
    Steela, Khoisnam
    Rajpurohit, Bharat Singh
    2014 IEEE 6TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2014,