Comparative biomechanical analysis of rigid vs. flexible fixation devices for the lumbar spine: A geometrically patient-specific poroelastic finite element study

被引:13
|
作者
Khalaf, Kinda [1 ,2 ]
Nikkhoo, Mohammad [3 ]
机构
[1] Khalifa Univ Sci & Technol, Dept Biomed Engn, POB 127788, Abu Dhabi, U Arab Emirates
[2] Hlth Engn Innovat Ctr, POB 127788, Abu Dhabi, U Arab Emirates
[3] Islamic Azad Univ, Dept Biomed Engn, Sci & Res Branch, Tehran, Iran
关键词
Poroelastic modeling; Finite element analysis; Patient-specific; Lumbar fixation device; Dynamic rod; Interspinous process devices; INTERBODY FUSION; MOTION SEGMENT; INTERVERTEBRAL DISCS; INTRADISCAL PRESSURE; LOAD-BEARING; ADJACENT; MODEL; STABILIZATION; DEGENERATION; VALIDATION;
D O I
10.1016/j.cmpb.2021.106481
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Lumbar spinal stenosis (LSS), or the narrowing of the spinal canal, continues to be the leading preoperative diagnosis for adults older than 65 years who undergo spine surgery. Although the treatment of LSS depends on its severity, the optimal surgical technique towards decreasing the risk of adjacent segment disease (ASD) remains elusive. This study aimed to comparatively analyze spinal biomechanics with rigid and flexible fixation devices (i.e., rigid and dynamic posterolateral fusion (PLF) and interspinous process (ISP) devices) during daily activities. Methods: Using a validated parametric poroelastic finite element modeling approach, 8 subject-specific pre-operative models were developed, and their validity was evaluated. Parametric FE models of the lumbar spines were then regenerated based on post-operation images for (A) rigid PLF (B) dynamic PLF (C) rigid ISP device (Coflex) and (D) flexible ISP device (DIAM) at L4-L5 level. Biomechanical responses for instrumented and adjacent intervertebral discs (IVDs) were analyzed and compared subject to static and cyclic loading. Results: The preoperative models were well comparable with previous works in literature. The postoperative results for the PLF and Coflex rigid systems, demonstrated greater ROM; higher values of stress and strain in the AF region; and increased disc height and fluid loss at the adjacent levels, as compared with the pre-op models and the post-op results of the flexible systems (i.e., dynamic PLF and DIAM). The calculated forces on the facet joint were of smaller magnitude for the ISP devices as compared to the PLF, particularly during extension. Conclusions: This study demonstrates that the dynamic PLF construct and DIAM implants could be effective to maintain the natural poroelastic characteristics of adjacent IVDs, which could be beneficial for enhancing long-term clinical outcomes. FEM provides clinicians with an invaluable patient-specific quantitative tool for informed surgical planning and discerning follow-up management. (c) 2021 Published by Elsevier B.V.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Biomechanical Comparison of Corticopedicular Spine Fixation versus Pedicle Screw Fixation in a Lumbar Degenerative Spondylolisthesis Finite Element Analysis Model
    Farooqi, Ali S.
    Narayanan, Rajkishen
    Canseco, Jose A.
    Vaccaro, Alexander R.
    WORLD NEUROSURGERY, 2024, 190 : E129 - E136
  • [22] Biomechanical Evaluation of Cortical Bone Trajectory Fixation with Traditional Pedicle Screw in the Lumbar Spine: A Finite Element Study
    Su, Kuo-Chih
    Chen, Kun-Hui
    Pan, Chien-Chou
    Lee, Cheng-Hung
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [23] Comparative finite element analysis of patient-specific tricuspid and bicuspid aortic valve
    Djorovic, Smiljana
    Filipovic, Nenad
    Milosavljevic, Aleksandar
    Velicki, Lazar
    2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2017, : 563 - 567
  • [24] Biomechanical Investigation Between Rigid and Semirigid Posterolateral Fixation During Daily Activities: Geometrically Parametric Poroelastic Finite Element Analyses (vol 9, 646079, 2021)
    Nikkhoo, Mohammad
    Lu, Meng-Ling
    Chen, Wen-Chien
    Fu, Chen-Ju
    Niu, Chi-Chien
    Lin, Yang-Hua
    Cheng, Chih-Hsiu
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [25] Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study
    Ching-Sung Kuo
    Hsuan-Teh Hu
    Ruey-Mo Lin
    Kuo-Yuan Huang
    Po-Chun Lin
    Zheng-Cheng Zhong
    Mu-Lin Hseih
    BMC Musculoskeletal Disorders, 11
  • [26] Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study
    Kuo, Ching-Sung
    Hu, Hsuan-Teh
    Lin, Ruey-Mo
    Huang, Kuo-Yuan
    Lin, Po-Chun
    Zhong, Zheng-Cheng
    Hseih, Mu-Lin
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [27] Biomechanical Effects of Thoracic Flexibility and Stiffness on Lumbar Spine Loading: A Finite Element Analysis Study
    Morimoto, Masatoshi
    Tripathi, Sudharshan
    Kodigudla, Manoj
    Motohashi, Emi
    Fujitani, Junzo
    Goel, Vijay K.
    Sairyo, Koichi
    WORLD NEUROSURGERY, 2024, 184 : E282 - E290
  • [28] Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study
    Arceri, Alberto
    Abdi, Pejman
    Mazzotti, Antonio
    Zielli, Simone Ottavio
    Artioli, Elena
    Langone, Laura
    Sgubbi, Federico
    Faldini, Cesare
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (07):
  • [29] Biomechanical analysis of Instrumented decompression and Interbody fusion procedures in Lumbar spine: a finite element analysis study
    Shivam Saini
    Nagaraj Manju Moger
    Manish Kumar
    Subrato Sarkar
    Samarth Mittal
    Syed Ifthekar
    Kaustubh Ahuja
    Indra Vir Singh
    Pankaj Kandwal
    Medical & Biological Engineering & Computing, 2023, 61 (7) : 1875 - 1886
  • [30] Biomechanical analysis of Instrumented decompression and Interbody fusion procedures in Lumbar spine: a finite element analysis study
    Saini, Shivam
    Moger, Nagaraj Manju
    Kumar, Manish
    Sarkar, Subrato
    Mittal, Samarth
    Ifthekar, Syed
    Ahuja, Kaustubh
    Singh, Indra Vir
    Kandwal, Pankaj