Strength of the fixation of patellar tendon bone grafts using a totally absorbable self-reinforced poly-L-lactide expansion plug and screw. An experimental study in a bovine cadaver

被引:20
|
作者
Tuompo, P
Partio, EK
JukkalaPartio, K
Pohjonen, T
Helevirta, P
Rokkanen, P
机构
[1] UNIV CENT HOSP,HYVINKAA DIST HOSP,HELSINKI,FINLAND
[2] UNIV CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,HELSINKI,FINLAND
[3] TAMPERE UNIV TECHNOL,BIOMAT LAB,FIN-33101 TAMPERE,FINLAND
来源
ARTHROSCOPY | 1996年 / 12卷 / 04期
基金
芬兰科学院;
关键词
expansion plug; SR-PLLA; totally absorbable fixation; patellar tendon graft; interference fixation; ACL reconstruction;
D O I
10.1016/S0749-8063(96)90035-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a bovine cadaver study, bone-tendon-bone graft fixation strength with different graft geometry and fixation devices was measured to evaluate the fixation strength of totally absorbable implants: a 6.0-mm expansion plug and 6.3-mm screw both made of self-reinforced polylactide (SR-PLLA). Comparison was made with 6.5-mm AO cancellous screw. Maximum tensile force to dislodge the bone plug from the bone tunnel was recorded. First, two preliminary tests were performed. in the first test, triangular bone plugs were used (9-mm diameter). The direction of the pull force was parallel to the bone tunnel. The maximum tensile forces were 786 N in femoral insertions and 625 N in tibial insertions, mean. After this, we evaluated the influence of change in the pullout direction. In the second test, a circular bone plug was used with no fixation but the direction of the pull force was parallel to the tibial or femoral axis and the bone plug (10-mm diameter) was in a 30 degrees to 40 degrees angle to the direction of the pull force and it was compressed to the tunnel (9-mm diameter). The maximum tensile forces were 783 N in femoral insertions and 695 N in tibial insertions, mean. In the final third test, we used a curved saw in harvesting the graft. This made a half-circular bone block with a diameter of 12 mm. The maximum tensile force to dislodge the bone plug from the bone tunnel was recorded and the pull force was in a 30 degrees to 40 degrees angle to the tunnel. The results were evaluated with Student's t-test and Mann-Whitney U-test, With the AO screw, the maximum tensile force to dislodge the bone plug from the bone tunnel was 2,113 +/- 407 N (mean +/- standard deviation) and it was better than the fixation strength of the SR-PLLA expansion plug, 1,379 +/- 328 N (P = .009, t-test) and better than the fixation strength of SR-PLLA screw, 1,454 +/- 230 N (P = .007, t-test), However, the maximum tensile force of both SR-PLLA implants in all measurements in the third test were above 1,100 N and it seems that the initial strength of totally absorbable implants is enough for the clinical use.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 29 条
  • [21] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30 and self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rabbits
    Pyhältö, T
    Lapinsuo, M
    Pätiälä, H
    Niiranen, H
    Törmälä, P
    Rokkanen, P
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2005, 16 (06) : 725 - 744
  • [22] Initial stability of femoral neck osteosynthesis with absorbable self-reinforced poly-L-lactide (SR-PLLA) and metallic screws:: A comparative study on 21 cadavers
    Vasenius, J
    Pohjonen, T
    Törmälä, P
    Penttilä, A
    Rokkanen, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 39 (02): : 171 - 175
  • [23] Intramedullary fixation of distal femoral diaphyseal osteotomies with absorbable self-reinforced poly-L-lactide and metallic intramedullary rods assessed by plain radiographs, quantitative computed tomography, and magnetic resonance imaging: An experimental study in rabbits
    Viljanen, J
    Kinnunen, T
    Bondestam, S
    Rokkanen, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 39 (02): : 222 - 228
  • [24] New generation biodegradable plate for fracture fixation: Comparison of bending strengths of mandibular osteotomies fixed with absorbable self-reinforced multi-layer poly-l-lactide plates and metallic plates - An experimental study in sheep
    Suuronen, R.
    Pohjonen, T.
    Wessman, L.
    Tormala, P.
    Vainionpaa, S.
    Clinical Materials, 1992, 9 (02): : 77 - 84
  • [25] BONE CHANGES AFTER EXPERIMENTAL OSTEOTOMIES FIXED WITH ABSORBABLE SELF-REINFORCED POLY-L-LACTIDE SCREWS OR METALLIC SCREWS STUDIED BY PLAIN RADIOGRAPHS, QUANTITATIVE COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING
    VILJANEN, J
    KINNUNEN, J
    BONDESTAM, S
    MAJOLA, A
    ROKKANEN, P
    TORMALA, P
    BIOMATERIALS, 1995, 16 (17) : 1353 - 1358
  • [26] Intramedullary fixation of cortical bone osteotomies with absorbable self-reinforced fibrillated poly-96L/4D-lactide (SR-PLA96) rods in rabbits
    Saikku-Bäckström, A
    Tulamo, RM
    Räihä, JE
    Kellomäki, M
    Toivonen, T
    Törmälä, P
    Rokkanen, P
    BIOMATERIALS, 2001, 22 (01) : 33 - 43
  • [27] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rats
    Tuomo, P
    Matti, L
    Hannu, P
    Pentti, R
    Henna, N
    Pertti, T
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) : 275 - 281
  • [28] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70 : 30/bioactive glass composite rods. An experimental study on rats
    Pyhältö Tuomo
    Lapinsuo Matti
    Pätiälä Hannu
    Rokkanen Pentti
    Niiranen Henna
    Törmälä Pertti
    Journal of Materials Science: Materials in Medicine, 2004, 15 : 275 - 281
  • [29] Strength retention of self-reinforced drawn poly-L/DL-lactide 70/30 (SR-PLA70) rods and fixation properties of distal femoral osteotomies with these rods.: An experimental study on rats
    Joukainen, A
    Pihlajamäki, H
    Mäkelä, EA
    Ashammakhi, N
    Viljanen, J
    Pätiälä, H
    Kellomäki, M
    Törmälä, P
    Rokkanen, P
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (12) : 1411 - 1428