A highly sensitive method for determination of β-blocker drugs using a Nafion-coated glassy carbon electrode

被引:29
|
作者
Nigovic, Biljana [1 ]
Marusic, Marija [1 ]
Juric, Sandra [1 ]
机构
[1] Univ Zagreb, Fac Pharm & Biochem, Zagreb 10000, Croatia
关键词
Bisoprolol fumarate; Propranolol hydrochloride; Adsorptive stripping voltammetry; Nafion; Modified glassy carbon electrode; TANDEM MASS-SPECTROMETRY; LC-MS/MS METHOD; HUMAN PLASMA; VOLTAMMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL FORMULATIONS; STRIPPING VOLTAMMETRY; COMPOSITE ELECTRODE; BISOPROLOL FUMARATE; PROPRANOLOL;
D O I
10.1016/j.jelechem.2011.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical response of bisoprolol fumarate (BF) and propranolol hydrochloride (PR) is significantly enhanced by immobilization of a Nafion film on the surface of the glassy carbon electrode. The positively charged drug molecules were accumulated in 0.1 mol L(-1) sulfuric acid solution at a potential of +0.6 V for 120 s, and then determined by square-wave anodic voltammetry. The enhancement mechanism and effect factors such as pH value, mass of Nafion, accumulation potential and pre-concentration time, were explored. The peak current is proportional to the concentration in the range from 5 x 10(-8) to 5 x 10(-7) mol L(-1) for BF and from 8 x 10(-8) to 6 x 10(-7) mol L(-1) for PR, with the sensitivities of 1.49 x 10(8) and 2.47 x 10(7) mu A mol(-1) L, respectively. The modified electrode was used to determine both beta-blockers in commercial tablets. The quantification of BF in urine samples with no prior extraction was carried out after selective accumulation at the electrode surface under stirring. Together with low cost and ease preparation, the modified electrode is a promising sensor in electroanalysis, not only for the detection of BF and PR, but also for other p-blocker drugs. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 78
页数:7
相关论文
共 50 条
  • [21] Sensitive Determination of Anticancer Drug Methotrexate Using Graphite Oxide-Nafion Modified Glassy Carbon Electrode
    Huang, Deqian
    Wu, Hai
    Zhu, Yuyang
    Su, Huijuan
    Zhang, Hong
    Sheng, Liangquan
    Liu, Zhaodi
    Xu, Huajie
    Song, Chongfu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3792 - 3804
  • [22] Electrochemical determination of calcium channel blocker drugs using multiwall carbon nanotube-modified glassy carbon electrode
    Sikkander, Abdul Razak Mohamed
    Vedhi, Chinnappiyan
    Manisankar, Paramasivam
    INTERNATIONAL JOURNAL OF INDUSTRIAL CHEMISTRY, 2012, 3 (01):
  • [23] Nafion-coated mercury thin film and glassy carbon electrodes for electroanalysis: Characterization by electrochemical impedance
    Brett, CMA
    Alves, VA
    Fungaro, DA
    ELECTROANALYSIS, 2001, 13 (03) : 212 - 218
  • [24] ELECTROCHEMICAL-BEHAVIOR AND PRECONCENTRATION OF URANYL(VI) AT NAFION-COATED GLASSY-CARBON ELECTRODES
    UGO, P
    BALLARIN, B
    DANIELE, S
    MAZZOCCHIN, GA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 324 (1-2): : 145 - 159
  • [25] Nafion-coated mercury thin film and glassy carbon electrodes for electroanalysis: Characterization by electrochemical impedance
    Brett, Christopher M. A.
    Alves, Valéria A.
    Fungaro, Denise A.
    2001, Wiley-VCH Verlag (13)
  • [26] AMPEROMETRIC DETECTION OF CATIONIC NEUROTRANSMITTERS AT NAFION-COATED GLASSY-CARBON ELECTRODES IN FLOW STREAMS
    WANG, J
    TUZHI, P
    GOLDEN, T
    ANALYTICA CHIMICA ACTA, 1987, 194 : 129 - 138
  • [27] ION-EXCHANGE OF CATIONIC DRUGS AT A NAFION-COATED ELECTRODE IN FLOW-THROUGH ANALYSIS
    ZHOU, JX
    WANG, E
    ANALYTICA CHIMICA ACTA, 1991, 249 (02) : 489 - 494
  • [28] A Simple and Sensitive Method for the Detection of Trace Pb(II) and Cd(II) based on Nafion-coated Antimony Film Electrode
    Xu He
    Yang Ping
    Zheng Qiaoli
    Liu Jianshe
    Jin Litong
    CHINESE JOURNAL OF CHEMISTRY, 2010, 28 (11) : 2287 - 2292
  • [29] Voltammetric determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode
    Caetano, Lahys G.
    Takeuchi, Regina M.
    Santos, Andre L.
    de Oliveira, Marcelo F.
    Stradiotto, Nelson R.
    FUEL, 2013, 106 : 837 - 842
  • [30] Determination of caffeine at a Nafion-covered glassy carbon electrode
    Brunetti, Barbara
    Desimoni, Elio
    Casati, Paolo
    ELECTROANALYSIS, 2007, 19 (2-3) : 385 - 388