Long-term monitoring of photovoltaic devices

被引:61
|
作者
van Dyk, EE
Meyer, EL
Vorster, FJ
Leitch, AWR
机构
[1] Univ Port Elizabeth, Dept Phys, ZA-6000 Port Elizabeth, South Africa
[2] Port Elizabeth Technikon, Dept Math Sci, ZA-6000 Port Elizabeth, South Africa
基金
新加坡国家研究基金会;
关键词
D O I
10.1016/S0960-1481(01)00064-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For photovoltaic (PV) devices to operate successfully over an expected lifespan of 30 years, much research is needed in all aspects of these devices. This study is concerned with the monitoring of the performance and degradation of PV devices over extended periods as well as the effect of meteorological conditions on device performance. The PV devices used in this study comprise different cell technologies and designs. The performance of conventional flat plate modules was monitored over a 15-month period and that of a PV concentrator array over a 13-month period. The results of this performance monitoring are presented in this paper. Degradation mechanisms of PV devices are also discussed. This study showed that, as expected, the power ratings of PV devices do not usually give an accurate indication of their performance outdoors. Results obtained also showed that meteorological conditions could cause an 18% reduction of a module's potential power. A degradation monitoring procedure revealed potential degradation mechanisms, such as mismatched cells, hot spot formation and low cell shunt resistances on some modules. A comparative study on the PV concentrator modules showed that the concentrator modules produced much less energy than their rated energy when operating outdoors. The energy performance of a tracked flat plate module vastly exceeded the concentrator modules' performance. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:183 / 197
页数:15
相关论文
共 50 条
  • [41] Long-term atmospheric corrosion monitoring
    Kobus, J
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2000, 51 (02): : 104 - 108
  • [42] Standardisation of Methods for Long-Term Monitoring
    Wenche Aas
    Arne Semb
    Water, Air, and Soil Pollution, 2001, 130 : 1595 - 1600
  • [43] Pattern monitoring and long-term measurements
    Lejkowski, Wojciech
    Dabrowski, Slawomir
    Switalski, Arkadiusz
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (10): : 151 - 156
  • [44] Long-term monitoring of railway tunnels
    Moritz, Bernd
    Heissenberger, Roman
    Schachinger, Tobias
    Lienhart, Werner
    Geomechanik und Tunnelbau, 2021, 14 (01): : 35 - 46
  • [45] Long-term monitoring of ARDS patients
    Demoule, A
    REVUE DES MALADIES RESPIRATOIRES, 2004, 21 (05) : S163 - S165
  • [46] LONG-TERM MONITORING AND TREATMENT OF LYMPHOGRANULOMATOSIS
    KUSE, R
    HAUSMANN, K
    BLUT, 1975, 31 (03): : 173 - 173
  • [47] Long-term monitoring of highway deformations
    Anderegg, P
    Brönnimann, R
    Raab, C
    Partl, M
    NONDESTRUCTIVE EVALUATION OF HIGHWAYS, UTILITIES, AND PIPELINES IV, 2000, 3995 : 459 - 466
  • [48] Long-term spectroscopic monitoring of Arcturus
    Brown, Kevin I. T.
    Gray, David F.
    Baliunas, Sallie L.
    ASTROPHYSICAL JOURNAL, 2008, 679 (02): : 1531 - 1540
  • [49] Guidelines for long-term monitoring protocols
    Oakley, KL
    Thomas, LP
    Fancy, SG
    WILDLIFE SOCIETY BULLETIN, 2003, 31 (04): : 1000 - 1003
  • [50] Long-term monitoring of Molonglo calibrators
    Gaensler, BM
    Hunstead, RW
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF AUSTRALIA, 2000, 17 (01): : 72 - 82