Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs

被引:14
|
作者
Heulitt, MJ
Holt, SJ
Thurman, TL
Hall, RA
Jo, CH
Simpson, P
机构
[1] Arkansas Childrens Hosp, Little Rock, AR 72202 USA
[2] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Sect Crit Care Med, Little Rock, AR 72205 USA
[3] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Biostat Sect, Little Rock, AR 72205 USA
关键词
respiratory physiology; mechanical ventilation; lung volume measurements; reproducibility of results;
D O I
10.1007/s00134-005-2717-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study examined whether volumes can be accurately measured at the expiratory valve of a conventional ventilator using pressure support ventilation and positive end expiratory pressure with software compensation for circuit compliance available in the Servo i ventilator. Design and setting: Comparison of two methods for measuring tidal volume in an animal laboratory. Subjects: Twenty healthy, intubated, sedated, spontaneously breathing pigs. Interventions: Volume was measured in ten neonatal-sized and ten pediatric-sized pigs ventilated with the Servo i' ventilator using pressure support ventilation and positive end expiratory pressure with and without circuit compliance compensation. We compared volume measured at the airway opening by pneumotachography to volume measured at the expiratory valve of a conventional ventilator. Measurements and results: The use of circuit compliance compensation significantly improved the agreement between the two volume methods in neonatal-sized piglets (concordance correlation coefficient: with circuit compliance compensation, 0.97; without, 0.87, p=0.002). In pediatric-sized pigs there was improvement in agreement between the two measurement methods due to circuit compliance compensation (concordance correlation coefficient with circuit compliance compensation, 0.97; without, 0.88, p=0.027). With circuit compliance compensation off there was positive bias: mean difference (bias) 2.97 +/- 0.12 in neonatal-sized and 3.75 +/- 0.38 in pediatric-sized pigs. Conclusions: Our results show that volume can be accurately measured at the expiratory valve of a conventional ventilator in neonatal- and pediatric-sized animals.
引用
收藏
页码:1255 / 1261
页数:7
相关论文
共 50 条
  • [21] Measurement of tidal volume using Respiratory Ultrasonic Plethysmography in anaesthetized, mechanically ventilated horses
    Russold, Elena
    Ambrisko, Tamas D.
    Schramel, Johannes P.
    Auer, Ulrike
    Van Den Hoven, Rene
    Moens, Yves P.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (01) : 48 - 54
  • [22] Influence of fluid and volume state on PaO2 oscillations in mechanically ventilated pigs
    Bodenstein, Marc
    Bierschock, Stephan
    Boehme, Stefan
    Wang, Hemei
    Vogt, Andreas
    Kwiecien, Robert
    David, Matthias
    Markstaller, Klaus
    EXPERIMENTAL LUNG RESEARCH, 2013, 39 (02) : 80 - 90
  • [23] ADHERENCE TO ≤ 8 MILLILITERS TIDAL VOLUME PER IDEAL BODY WEIGHT IN MECHANICALLY VENTILATED PATIENTS
    Goodrich, Andrew
    Schmidt, Ulrich
    Nguyen, Albert
    CRITICAL CARE MEDICINE, 2021, 49 (01) : 511 - 511
  • [24] Tidal Volume in Patients With Normal Lungs during General Anesthesia Lower the Better?
    Wrigge, Hermann
    Pelosi, Paolo
    ANESTHESIOLOGY, 2011, 114 (05) : 1011 - 1013
  • [25] The influence of a PEEP-wave maneuver on lung recruitment in healthy and injured lungs: a study in mechanically ventilated pigs
    Lozano-Zahonero, S.
    Buehler, S.
    Runck, H.
    Gamerdinger, K.
    Foerster, K.
    Haberstroh, J.
    Schumann, S.
    Guttman, J.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S233 - S235
  • [26] Tidal Volume and Mortality in Mechanically Ventilated Children: A Systematic Review and Meta-Analysis of Observational Studies
    de Jager, Pauline
    Burgerhof, Johannes G. M.
    van Heerde, Marc
    Albers, Marcel J. I. J.
    Markhorst, Dick G.
    Kneyber, Martin C. J.
    CRITICAL CARE MEDICINE, 2014, 42 (12) : 2461 - 2472
  • [27] The value of respiratory rate-tidal volume ratio as a weaning parameter for mechanically ventilated COPD patients
    Tryfon, SM
    Stanopoulos, I
    Kyriakakis, A
    Babalis, C
    Ambatzidou, F
    Mavrofridis, E
    INTENSIVE CARE MEDICINE, 2001, 27 : S268 - S268
  • [28] Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of tidal volume
    Mouloudi, E
    Katsanoulas, K
    Anastasaki, M
    Hoing, S
    Georgopoulos, D
    INTENSIVE CARE MEDICINE, 1999, 25 (11) : 1215 - 1221
  • [29] GLOBAL DISTRIBUTION OF TIDAL VOLUME BEFORE AND DURING NEUROMUSCULAR BLOCKADE IN MECHANICALLY VENTILATED CHILDREN: A PILOT STUDY
    Wilsterman, M. E. F.
    Veldsema-Hakvoort, B.
    Engels, B.
    Markhorst, D. G.
    Albers, M. J. I. J.
    Kneyber, M. C. J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S328 - S328
  • [30] Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
    C Costa
    S Vieira
    G Friedman
    L Fialkow
    Critical Care, 13 (Suppl 1):