Quality assessment and microbiologic screening of donor corneas

被引:10
|
作者
Hassan, Sohela S.
Wilhelmus, Kirk R.
机构
[1] Cullen Eye Inst, Houston, TX 77030 USA
[2] Baylor Coll Med, Lions Eye Bank Texas, Houston, TX USA
[3] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
关键词
corneal preservation; donor cornea; eye banking; transplantation;
D O I
10.1097/ICO.0b013e31811dfb72
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify possible predictors of donor corneal contamination. Methods: Relationships between eye-banking characteristics of donor corneas and surgical corneoscleral rim culture results were examined in a retrospective case-control study by using logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Results: Of 263 donor corneal rims, microbial recovery occurred from 23 (9%), including 6 yielding Clostridium perfringens. After adjusting for outdoor temperature and death-to-preservation duration, a positive rim culture occurred more often among tissues having an acceptable but less favorable biomicroscopic rating (OR, 4.22; 95% CI, 1.27-13.98). Conclusions: This exploratory study suggests that slit-lamp assessment of corneal appearance may correlate with subsequent microbiologic results. Ensuring optimal selection and preservation of the donor cornea may contribute to the safety of eye banking.
引用
收藏
页码:953 / 955
页数:3
相关论文
共 50 条
  • [31] LOSS OF ENDOTHELIUM IN STORED DONOR CORNEAS
    SCHIMMELPFENNIG, B
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 192 (05) : 605 - 606
  • [32] EFFECTIVENESS OF A DECONTAMINATION METHOD FOR DONOR CORNEAS
    BADENOCH, PR
    ALFRICH, SJ
    WEDDING, TR
    COSTER, DJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1988, 72 (03) : 225 - 227
  • [33] Obtaining donor corneas without the bulb
    Kunster, A
    Eckardt, U
    Eckardt, C
    OPHTHALMOLOGE, 1997, 94 (02): : 94 - +
  • [34] Validation of Tissue Quality Parameters for Donor Corneas Designated for Emergency Use in Preservation of the Globe
    Rijneveld, Wilhelmina J.
    Wolff, Rachel
    Volker-Dieben, Hennie J.
    Pels, Elisabeth
    CORNEA, 2010, 29 (02) : 128 - 132
  • [35] Should antibody to hepatitis B core antigen be tested in routine screening of donor corneas for transplant?
    Mattern, RM
    Cavanagh, HD
    CORNEA, 1997, 16 (02) : 138 - 145
  • [36] KERATOPLASTY RESULTS OF PAIRED DONOR CORNEAS
    WHITE, SM
    SOUTHERN MEDICAL JOURNAL, 1966, 59 (09) : 1071 - &
  • [37] INFANT DONOR CORNEAS FOR PENETRATING KERATOPLASTY
    WOOD, TO
    NISSENKORN, I
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (07): : 500 - 502
  • [38] Cryopreservation of human donor corneas with dextran
    Halberstadt, M
    Böhnke, M
    Athmann, S
    Hagenah, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (12) : 5110 - 5115
  • [39] CLEARING OF BILIRUBIN FROM DONOR CORNEAS
    WESLEY, RE
    OPHTHALMOLOGY, 1990, 97 (01) : 5 - 5
  • [40] A NEW SYSTEM FOR STORING DONOR CORNEAS
    BOHNKE, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1991, 198 (02) : 135 - 137