Quality assessment and microbiologic screening of donor corneas

被引:10
|
作者
Hassan, Sohela S.
Wilhelmus, Kirk R.
机构
[1] Cullen Eye Inst, Houston, TX 77030 USA
[2] Baylor Coll Med, Lions Eye Bank Texas, Houston, TX USA
[3] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
关键词
corneal preservation; donor cornea; eye banking; transplantation;
D O I
10.1097/ICO.0b013e31811dfb72
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify possible predictors of donor corneal contamination. Methods: Relationships between eye-banking characteristics of donor corneas and surgical corneoscleral rim culture results were examined in a retrospective case-control study by using logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Results: Of 263 donor corneal rims, microbial recovery occurred from 23 (9%), including 6 yielding Clostridium perfringens. After adjusting for outdoor temperature and death-to-preservation duration, a positive rim culture occurred more often among tissues having an acceptable but less favorable biomicroscopic rating (OR, 4.22; 95% CI, 1.27-13.98). Conclusions: This exploratory study suggests that slit-lamp assessment of corneal appearance may correlate with subsequent microbiologic results. Ensuring optimal selection and preservation of the donor cornea may contribute to the safety of eye banking.
引用
收藏
页码:953 / 955
页数:3
相关论文
共 50 条
  • [1] Analysis in Results of Microbiologic Exam Related to Donor Corneas
    Jung, Il
    Ko, Byung Yi
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (03): : 236 - 241
  • [2] Microbiologic study of organ-cultured donor corneas
    Borderie, VM
    Laroche, L
    TRANSPLANTATION, 1998, 66 (01) : 120 - 123
  • [3] Assessment of endothelium from donor corneas
    Panda, A
    Pangtey, MS
    Sony, P
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (01) : 123 - 123
  • [4] VIDEO SPECULAR MICROSCOPIC SCREENING OF DONOR CORNEAS
    SIECK, EA
    CORNEA, 1995, 14 (06) : 589 - 589
  • [5] Screening donor corneas that have undergone PRK
    Mannis, MJ
    McDonough, G
    Howard, K
    Morales, R
    Sugar, J
    CORNEA, 1997, 16 (06) : 683 - 685
  • [6] Microbiological Screening of Hypothermic Preserved Donor Corneas in Keratoplasty
    Li, Saiqun
    Zhong, Jing
    Tan, Yiwei
    Deng, Yuqing
    Huang, Haixiang
    Wang, Bowen
    Peng, Lulu
    Zhang, Henan
    Yuan, Jin
    CURRENT EYE RESEARCH, 2019, 44 (10) : 1067 - 1074
  • [7] Objective screening for the detection of refractive surgery on donor corneas
    Hick, S
    Laliberté, JF
    Meunir, J
    Ousley, PJ
    Terry, MA
    Brunette, MA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U481 - U481
  • [8] Molecular screening of donor corneas for fungi before excision
    Kercher, L
    Wardwell, SA
    Wilhelmus, KR
    Mitchell, BM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (11) : 2578 - 2583
  • [9] Evaluation of the quality of donor corneas in relation to the age of donor and cause of death
    Pantaleao, Gleisson Rezende
    Zapparolli, Marcio
    Guedes, Guilherme Barroso
    Dimartini Junior, Wilson Moreira
    Vidal, Cristiane Carvalho
    Wasilewski, Daniel
    Moreira, Hamilton
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (05) : 631 - 635
  • [10] Conjunctival and intraocular swabs for the microbiological assessment of donor corneas
    Fuest, Matthias
    Plum, Wolfgang
    Salla, Sabine
    Walter, Peter
    Hermel, Martin
    ACTA OPHTHALMOLOGICA, 2016, 94 (01) : 70 - 75