Determination of tin in iron and steel by differential pulse anodic stripping voltammetry at a rotating gold film electrode

被引:1
|
作者
Tanaka, T [1 ]
Sato, T [1 ]
Omote, K [1 ]
机构
[1] Sci Univ Tokyo, Fac Engn, Dept Ind Chem, Shinjuku Ku, Tokyo 1628601, Japan
关键词
D O I
10.1246/nikkashi.2001.97
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and sensitive method is described for the determination of tin in iron and steel by differential pulse anodic stripping voltammetry at a gold-coated glassy carbon electrode. Tin(IV) could be quantitatively eletctrodeposited by the addition of high concentrations of bromide. The interference of the iron(III) matrix was eliminated by reducing it to ironn (II) with L(+)-ascorbic acid. Pre-electrolysis was carried out in 0.3 mol dm(-3) hydrochloric acid-0.1 mol dm(-3) nitric acid containing 2 mol dm(-3) sodium bromide and 0.2 mol dm(-3) L(+)-ascorbic acid at a potential of -0.5V as. Ag/AgCl for 300 s. The deposits were stripped at a scan rate of 40 mV s(-1) to 0 V vs. Ag/AgCl. The calibration (peak height as. tin (IV) concentration) graph in the presence of 1000 mug cm(-3) Fe(II) was linear over a concentration range 8.3. x 10(-9) to 3.4 x 10(-7) mol dm(-3) of tin(IV) and passed through the origin, with a relative standard deviation of 4.3% for 20 ng cm(-3)(n = 5). The detection limit (3 sigma) was 2.8 x 10(-9) mol dm(-3). There were serious interferences due to overlapping stripping peaks of cadmium (II) and copper( II). The determination of 120 to 400 mug g(-1) of tin in iron and steel was achieved with good precision and accuracy within 50 min without any preliminary separation of the matrix. The proposed method is applicable to the determination of tin down to 1 mug g(-1) levels in scrap iron.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 50 条
  • [21] Determination of iodine ion by differential pulse anodic stripping voltammetry
    Tian, Yuan
    Song, Wen-Bo
    Jiang, Yan-Xia
    Liu, Ying
    Chen, Xu
    Xu, Hong-Ding
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1999, 20 (01): : 28 - 31
  • [23] PERFORMANCE OF A PALLADIUM FILM ELECTRODE FOR THE DETERMINATION OF THALLIUM AND LEAD IN NATURAL WATER SAMPLE BY DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    Santos, Jorge Luis O.
    Leite, Oldair D.
    Janoni, Clayton Ricardo
    de Jesus, Djane S.
    dos Santos, Ana Maria P.
    QUIMICA NOVA, 2017, 40 (09): : 989 - 997
  • [24] Determination of trace tin by anodic stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Xie, Hong-Qi
    Zhou, Fang-Qin
    Guo, Hui-Shi
    ELECTROANALYSIS, 2006, 18 (10) : 976 - 980
  • [25] DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY AT THE WALL JET ELECTRODE
    GUNASINGHAM, H
    ANG, KP
    NGO, CC
    THIAK, PC
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 198 (01) : 27 - 35
  • [26] Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode
    Kumric, Ksenija R.
    Trtic-Petrovic, Tatjana M.
    Ignjatovic, Ljubisa M.
    Comor, Jozef J.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (01): : 65 - 69
  • [27] The renovated silver ring electrode in determination of lead traces by differential pulse anodic stripping voltammetry
    Bas, Boguslaw
    Jakubowska, Malgorzata
    ANALYTICA CHIMICA ACTA, 2008, 615 (01) : 39 - 46
  • [28] DETERMINATION OF SELENIUM AND TELLURIUM IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE
    HAMILTON, TW
    ELLIS, J
    FLORENCE, TM
    ANALYTICA CHIMICA ACTA, 1979, 110 (01) : 87 - 94
  • [29] DETERMINATION OF ARSENIC AND ANTIMONY IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE
    HAMILTON, TW
    ELLIS, J
    FLORENCE, TM
    ANALYTICA CHIMICA ACTA, 1980, 119 (02) : 225 - 233
  • [30] DETERMINATION OF ARSENIC(III) BY PULSE STRIPPING VOLTAMMETRY AT A GOLD ELECTRODE