Pediatric intraocular lens power calculations

被引:16
|
作者
O'Hara, Mary A. [1 ,2 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Dept Pediat, Sacramento, CA 95817 USA
关键词
intraocular lens power calculation; myopic shift; pediatric cataract surgery; pediatric intraocular lens implantation; AXIAL LENGTH; IMPLANTATION; ACCURACY; ERROR; KERATOMETRY; FORMULAS; OUTCOMES; EYES;
D O I
10.1097/ICU.0b013e32835622f8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review To implant an appropriate intraocular lens (IOL) in a child, we must measure the eye well, calculate the IOL power accurately and predict the refractive change of the pseudophakic eye to maturity. The present review will concentrate on recent studies dealing with these issues. Recent findings Immersion A-scan biometry is superior in measuring the axial length of children. Current IOL power calculation formulas are very accurate in adults, but significantly less accurate in children. Several studies point to the high prediction errors encountered particularly in shorter eyes with all available IOL formulas. Postoperative refraction target remains controversial, but low degrees of overcorrection (i.e. hyperopia) may not adversely affect eventual best-corrected visual acuity. Summary Although pediatric IOL power calculations suffer from significant prediction error, these errors can be decreased by careful preoperative measurements. IOL power calculation formulas are most accurate in the older, more 'adult'-sized eye. The smallest eyes have the most prediction error with all available formulas. Individual circumstances and parental concerns must be factored into the choice of a postoperative refractive target.
引用
收藏
页码:388 / 393
页数:6
相关论文
共 50 条
  • [21] IMPROVING THE PREDICTABILITY OF INTRAOCULAR-LENS POWER CALCULATIONS
    HOLLADAY, JT
    PRAGER, TC
    RUIZ, RS
    LEWIS, JW
    ROSENTHAL, H
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (04) : 539 - 541
  • [22] INTRAOCULAR-LENS POWER CALCULATIONS - THE OPTIMAL APPROACH
    BOERRIGTER, RMM
    THIJSSEN, JM
    VERBEEK, AM
    OPHTHALMOLOGICA, 1985, 191 (02) : 89 - 94
  • [23] INTRAOCULAR-LENS POWER CALCULATIONS IN THE TRIPLE PROCEDURE
    ABDELHAKIM, AS
    KHALIL, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (09) : 709 - 713
  • [24] Intraocular Lens Calculations
    Aristodemou, Petros
    Cartwright, Nathaniel Knox
    Sparrow, John M.
    Johnston, Robert
    OPHTHALMOLOGY, 2011, 118 (06) : 1221 - 1221
  • [25] Predictability of intraocular lens power calculation in pediatric cataract
    Lesueur, L
    Arne, JL
    Chapotot, E
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1999, 22 (02): : 209 - 212
  • [26] INTRAOCULAR-LENS IMPLANT POWER CALCULATIONS - INVESTIGATIONS CONTROLLING FOR LENS TYPE
    COBURN, RM
    GRANDON, SC
    GRANDON, GM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04): : 457 - 464
  • [27] Intraocular Lens Power Calculations Using Dual Scheimpflug Analyzer
    Lee, Young Bok
    Yi, Ka Young
    Bae, So Hyun
    Kim, Ha Kyoung
    Hyon, Joon Young
    Wee, Won Ryang
    Shin, Young Joo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 369 - 379
  • [28] Intraocular lens power calculations in eyes with previous radial keratotomy
    Wang, Li
    Waisbren, Emily
    Weikert, Mitchell P.
    Koch, Douglas D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] INTEGRATED ISEIKONIC EQUATION FOR INTRAOCULAR-LENS POWER CALCULATIONS
    SHAMMAS, HJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 74 - 77