Measurement and analysis of switching transients in 500kV substations

被引:0
|
作者
Zhang, WD [1 ]
Cui, X [1 ]
Wang, S [1 ]
Gu, XS [1 ]
机构
[1] N China Elect Power Univ, Baoding 071003, Hebei, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high voltage substations, secondary equipments placed in the switchyard and inside the control house can be highly sensitive to the transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipments, it is necessary to measure and analyze these transient electromagnetic disturbances. During three new 500kV substations powered on, many transient electromagnetic disturbances were measured and recorded. Based on FFT transform, the analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given in this paper.
引用
收藏
页码:391 / 393
页数:3
相关论文
共 50 条
  • [31] Simulation Analysis of Magnetizing Inrush Current of 500kV Transformer
    Zhu, Shengyi
    Wang, Tongtong
    Jin, Haiqiang
    Wen, Jun
    2020 6TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, CONTROL AND ROBOTICS (EECR 2020), 2020, 853
  • [32] Analysis of 500kV Capacitive Voltage Transformer Leakage Fault
    Yu Bing
    Zhao Lin
    Lin Haofan
    Zhou Luyao
    Yang Zhi
    Liu Shuang
    2021 THE 6TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2021), 2021, : 403 - 407
  • [33] Numerical Analysis of Frequency Electromagnetic Field of 500kV Substation
    Chu, Xiaorui
    ELECTRONIC INFORMATION AND ELECTRICAL ENGINEERING, 2012, 19 : 648 - 652
  • [34] Fracture analysis of 500kV composite insulators suspension clamp
    Han, Guodong
    Wu, Zhangqin
    Wan, Shuting
    Lv, Zhanjie
    Liu, Ronghai
    Wang, Jin
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 531 - +
  • [35] Switching Transient and Electrical Resonance Evaluation of 500kV Four Circuits Transmission Line
    Pramana, Putu Agus Aditya
    Kusuma, Aristo Adi
    Munir, Buyung Sofiarto
    Hendriyono, Devi
    2016 6TH INTERNATIONAL ANNUAL ENGINEERING SEMINAR (INAES), 2016, : 280 - 285
  • [36] Analysis and measurement of radio-frequency interfernce due to the corona from 500kV transmission lines
    Phaiboon, S
    Vivek, V
    Somkuarnpanit, S
    IEEE 2000 TENCON PROCEEDINGS, VOLS I-III: INTELLIGENT SYSTEMS AND TECHNOLOGIES FOR THE NEW MILLENNIUM, 2000, : 88 - 91
  • [37] 菲律宾500kV输电系统
    刘恩德
    国际电力, 2002, (04) : 44 - 46
  • [38] 500kV电缆的选型
    卢永魁
    于青
    邬楠
    尹晓东
    电线电缆, 2016, (03) : 44 - 46
  • [39] Analysis on switching overvoltage of 500 kV GIS disconnector
    Ren Hongtao
    ENERGY REPORTS, 2022, 8 : 169 - 176
  • [40] DEVELOPMENT OF 500KV SUBMARINE OF CABLE
    HIROSE, K
    TAKADA, M
    KIKUCHI, K
    TSUMOTO, M
    WATANABE, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 716 - 723