Impact of wood combustion on indoor air quality

被引:37
|
作者
Vicente, E. D. [1 ]
Vicente, A. M. [1 ]
Evtyugina, M. [1 ]
Oduber, F. I. [2 ]
Amato, F. [3 ]
Querol, X. [3 ]
Alves, C. [1 ]
机构
[1] Univ Aveiro, Dept Environm & Planning, Ctr Environm & Marine Studies, P-3810193 Aveiro, Portugal
[2] Univ Leon, Dept Phys, IMARENAB, E-24071 Leon, Spain
[3] CSIC, Spanish Res Council, ID EA, Inst Environm Assessment & Water Res, Barcelona 08034, Spain
关键词
Mediterranean region; Indoor air quality; OC/EC; Organic markers; PM10; Residential biomass combustion; POLYCYCLIC AROMATIC-HYDROCARBONS; FINE-PARTICLE EMISSIONS; PARTICULATE MATTER CONCENTRATIONS; CHEMICAL-CHARACTERIZATION; ATMOSPHERIC AEROSOLS; SOURCE APPORTIONMENT; OPERATING-CONDITIONS; ELEMENTARY-SCHOOLS; GASEOUS EMISSIONS; MOLECULAR TRACERS;
D O I
10.1016/j.scitotenv.2019.135769
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The incomplete wood combustion in appliances operated in batch mode is a recognised source of both in- and outdoor airborne pollutants, especially particulate matter (PM). Data on pollutant levels and PM characteristics in households with wood burning devices in developed countries are scarce with most studies describing stove change out programmes or other intervention measures. The aim of the present study was to simultaneously evaluate indoor and outdoor concentrations of CO, CO2 and PM10 during the operation of wood burning appliances (open fireplace and woodstove) in unoccupied rural households. PM10 samples were analysed for water soluble inorganic ions, major and trace elements, organic carbon (OC), elemental carbon (EC), and detailed organic speciation. The CO 8-hour average concentrations did not exceed the protection limit despite the sharp increases observed in relation to background levels. During the open fireplace operation, PM10 levels rose up 12 times compared to background concentrations, while the airtight stove resulted in a 2-fold increase. The inhalation cancer risk of particulate bound PAHs in the room equipped with woodstove was estimated to be negligible while the long-term exposure to PAH levels measured in the fireplace room may contribute to the development of cancer. The excess lifetime cancer risk resulting from the partide-bound Cr(VI) exposure during the fireplace and woodstove operation was higher than 1.0 x 10(-6) and 1.0 x 10(-5), respectively. Levoglucosan was one of the most abundant individual species both indoors and outdoors. This study underlines air pollution hazards and risks arising from the operation of traditional wood burning appliances. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Impact of indoor surface material on perceived air quality
    Senitkova, I.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 36 : 1 - 6
  • [42] Emissions and treatment of VOCs emitted from wood-based construction materials: Impact on indoor air quality
    Harb, P.
    Locoge, N.
    Thevenet, F.
    CHEMICAL ENGINEERING JOURNAL, 2018, 354 : 641 - 652
  • [43] Numerical Simulation of Air Distribution's Impact on Indoor Air Quality
    Zhang, Min
    Zhao, Bin
    3RD INTERNATIONAL CONFERENCE ON APPLIED ENGINEERING, 2016, 51 : 1 - 6
  • [44] IMPACT OF THERMAL PROOFING OF A CHURCH ON ITS INDOOR AIR-QUALITY - THE COMBUSTION OF CANDLES AND INCENSE AS A SOURCE OF POLLUTION
    HUYNH, CK
    SAVOLAINEN, H
    VUDUC, T
    GUILLEMIN, M
    ISELIN, F
    SCIENCE OF THE TOTAL ENVIRONMENT, 1991, 102 : 241 - 251
  • [45] EFFECTS OF WOOD PRESERVATIVES ON THE COMBUSTION PROCESS AND COMBUSTION QUALITY OF WOOD
    Yasar, S. Sadiye
    WOOD RESEARCH, 2019, 64 (01) : 59 - 70
  • [46] Impact of condensate cooled air purging on indoor air quality in an air conditioned laboratory
    Palanisamy, Dhamodharan
    Ayalur, Bakthavatsalam Kannappan
    BUILDING AND ENVIRONMENT, 2021, 188
  • [47] Impact of Wood Aging on Fuel Quality and Combustion Chemistry in a Wood-burning Stove
    Endriss, Felix
    Grammer, Peter
    Russ, Michael
    Thorwarth, Harald
    CHEMIE INGENIEUR TECHNIK, 2021, 93 (10) : 1598 - 1609
  • [48] FORMALDEHYDE-FREE COMPOSITE WOOD PRODUCTS FOR IMPROVED INDOOR AIR QUALITY
    Nakos, P.
    Athanassiadou, E.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2006, 7 (02): : 414 - 421
  • [49] On indoor air pollution and indoor air quality control
    Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Chongqing University, Chongqing 400045, China
    不详
    Chongqing Jianzhu Daxue Xuebao, 2007, 6 (108-112):
  • [50] Assessment of indoor air quality of porous media combustion-based cookstoves
    Pratibha Maurya
    Muthukumar Palanisamy
    Anandalakshmi Ramalingam