The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques

被引:34
|
作者
Wada, A [1 ]
Kubota, H [1 ]
Hatanaka, H [1 ]
Hotokezaka, S [1 ]
Miura, H [1 ]
Iwamoto, Y [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
来源
关键词
D O I
10.1054/jhsb.2000.0441
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have compared the effect of locking and grasping suture loop configurations in four-strand core suture techniques for tendon repair. Forty canine flexor digitorum profundus tendons were repaired with one of four suture techniques (the grasping cruciate, the double-modified grasping Kessler, the locking cruciate and the double-modified locking Kessler) and tested to failure in a tensile testing machine. The mode of failure in all the locking suture specimens was breakage of the sutures in the locking loops or at suture knots. The sutures did not pull out of the tendon, as was seen in the grasping suture specimens. The greatest tensile strength was found with the double-modified locking Kessler technique which incorporated eight rectangular locking loop configurations.
引用
收藏
页码:548 / 551
页数:4