The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques

被引:34
|
作者
Wada, A [1 ]
Kubota, H [1 ]
Hatanaka, H [1 ]
Hotokezaka, S [1 ]
Miura, H [1 ]
Iwamoto, Y [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
来源
关键词
D O I
10.1054/jhsb.2000.0441
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have compared the effect of locking and grasping suture loop configurations in four-strand core suture techniques for tendon repair. Forty canine flexor digitorum profundus tendons were repaired with one of four suture techniques (the grasping cruciate, the double-modified grasping Kessler, the locking cruciate and the double-modified locking Kessler) and tested to failure in a tensile testing machine. The mode of failure in all the locking suture specimens was breakage of the sutures in the locking loops or at suture knots. The sutures did not pull out of the tendon, as was seen in the grasping suture specimens. The greatest tensile strength was found with the double-modified locking Kessler technique which incorporated eight rectangular locking loop configurations.
引用
收藏
页码:548 / 551
页数:4
相关论文
共 35 条
  • [1] COMPARISON OF LOCKING AND GRASPING LOOP CONFIGURATIONS USING FIBERWIRE IN FOUR-STRAND CRUCIATE FLEXOR TENDON REPAIR
    Chiu, S.
    Meineke, R.
    Wongworawat, M. D.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2010, 58 (01) : 149 - 149
  • [2] Influence of core suture purchase length on strength of four-strand tendon repairs
    Cao, Y
    Zhu, B
    Xie, RG
    Tang, JB
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01): : 107 - 112
  • [3] Differences between locking loops and grasping loops: Effects on 2-strand core suture
    Hotokezaka, S
    Manske, PR
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (06): : 995 - 1003
  • [4] Four-Strand Core Suture Improves Flexor Tendon Repair Compared to Two-Strand Technique in a Rabbit Model
    Wichelhaus, Alice
    Beyersdoerfer, Sascha Tobias
    Vollmar, Brigitte
    Mittlmeier, Thomas
    Gierer, Philip
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [5] Suture Augmentation of a Four-Strand Semitendinosus Graft Improves Time-Zero Biomechanical Properties
    Wallace, Garrett J.
    Thompson, Daniel
    Diekfuss, Jed A.
    Champagne, Allen A.
    Myer, Gregory D.
    Kaiser, Jarred
    Lamplot, Joseph D.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (01): : 124 - 132
  • [6] A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair
    Lawrence, TA
    Davis, TRC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 836 - 841
  • [7] The Four-Strand Staggered Suture for Flexor Tendon Repair: In Vitro Biomechanical Study
    Corradi, Maurizio
    Bellan, Monia
    Frattini, Marco
    Concari, Galeazzo
    Tocco, Silvio
    Pogliacomi, Francesco
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (06): : 948 - 955
  • [8] Effect of suture size on locking and grasping flexor tendon repair techniques
    Hatanaka, H
    Manske, PR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (375) : 267 - 274
  • [9] Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair
    Joyce, C. W.
    Whately, K. E.
    Chan, J. C.
    Murphy, M.
    O'Brien, F. J.
    Carroll, S. M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (01) : 40 - 45
  • [10] Comparison of locking, uni-locking and grasping suture techniques in flexor tendon repair.
    Hunt, IC
    Sharma, S
    Trumble, T
    JOURNAL OF INVESTIGATIVE MEDICINE, 2004, 52 (01) : S81 - S81