Packed bed column studies on Cd(II) removal from industrial wastewater by macrofungus Pleurotus platypus

被引:46
|
作者
Vimala, R. [1 ]
Charumathi, D. [1 ]
Das, Nilanjana [1 ]
机构
[1] VIT Univ, Sch Biosci & Technol, Environm Biotechnol Div, Vellore 632014, Tamil Nadu, India
关键词
Macrofungus; Pleurotus platypus; Column; BDST model; Cadmium (II); Biosorption; AQUEOUS-SOLUTIONS; HEAVY-METALS; BIOSORPTION; ADSORPTION; IONS; DESIGN;
D O I
10.1016/j.desal.2011.03.014
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The removal of Cd (II) from industrial wastewater by macrofungus Pleurotus platypus was investigated in a fixed bed column. Experiments were conducted to study the effect of important parameters such as bed depth (5-15 cm) and flow rate (5-15 ml min(-1)). The bed depth service time model (BDST) fitted well with the experimental data and the adsorption capacity (N-0) estimated from this model was 2418.12 mg L-1. The effect of co-ions on adsorption of cadmium (II) was analyzed as single and multimetal systems. The breakthrough and exhaustion points were found to be earlier for biosorption of cadmium (II) in the presence of co-ions. The biosorbent was employed for the treatment of industrial effluent in a continuous column mode and its reusability was assessed. The column was regenerated by eluting cadmium (II) using 0.01 M HCl and the adsorbent was reused for three sorption-desorption cycles without considerable loss in biosorption capacity. In the three cycles of biosorption, about 3.6 L of industrial effluent could be treated to reach the Cd (II) standard (0.1 mg L-1) established by the Central Pollution Control Board (CPCB). P. platypus proved to be the potential biosorbent for the removal of Cd (II) from industrial effluents. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [11] Biosorption study on Ni(II) and Cd(II) removal in a packed bed column using brewery sludge pellets
    Kulkarni, Rajeswari M.
    Shetty, K. Vidya
    Srinikethan, G.
    BIOMASS CONVERSION AND BIOREFINERY, 2024, 14 (13) : 14291 - 14302
  • [12] Packed bed column studies for the removal of synthetic dyes from textile wastewater using immobilised dead C. tropicalis
    Charumathi, D.
    Das, Nilanjana
    DESALINATION, 2012, 285 : 22 - 30
  • [13] Removal of Pb(II) Ions in Fixed-Bed Column from Electroplating Wastewater of Bursa, an Industrial City in Turkey
    Kara, Ali
    Ustun, Gokhan Ekrem
    Solmaz, Seval Kutlu Akal
    Demirbel, Emel
    JOURNAL OF CHEMISTRY, 2013, 2013
  • [14] Removal of Cd(II) Ions from Aqueous Solutions Using Immobilized Spent Substrates of Pleurotus ostreatus in a Fixed-Bed Column
    Qu, Juanjuan
    Li, Yue
    Zang, Tingting
    Jin, Yu
    Liu, Xuesheng
    Yan, Lei
    ENVIRONMENTAL ENGINEERING SCIENCE, 2019, 36 (09) : 1162 - 1169
  • [15] PACKED BED COLUMN STUDIES FOR THE REMOVAL OF DYES USING NOVEL SORBENT
    Rajeshkannan, R.
    Rajasimman, M.
    Rajamohan, N.
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2013, 19 (04) : 461 - 470
  • [16] Continuous removal of copper, magnesium, and nickel from industrial wastewater utilizing the natural product yersiniabactin immobilized within a packed-bed column
    Moscatello, Nicholas
    Swayambhu, Girish
    Jones, Charles H.
    Xu, Jiale
    Dai, Ning
    Pfeifer, Blaine A.
    CHEMICAL ENGINEERING JOURNAL, 2018, 343 : 173 - 179
  • [17] Removal of Cr(VI) and Pb(II) from Wastewater by ZeoliteNaX in Fixed Bed Column
    Pandey P.K.
    Sharma S.K.
    Water Conservation Science and Engineering, 2017, 2 (3) : 61 - 65
  • [18] Packed-Column of Granular Activated Carbons for Removal of Chemical Oxygen Demand from Industrial Wastewater
    Laohaprapanon, Sawanya
    Marques, Marcia
    Kaczala, Fabio
    Hogland, William
    CLEAN-SOIL AIR WATER, 2013, 41 (03) : 244 - 250
  • [19] Column performance of granular activated carbon packed bed for Pb(II) removal
    Dwivedi, Chandra P.
    Sahu, J. N.
    Mohanty, C. R.
    Mohan, B. Raj
    Meikap, B. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 156 (1-3) : 596 - 603
  • [20] Batch and Packed Bed Column Study for the Removal of Cr (VI) and Ni (II) Using Agro-Industrial Wastes
    Tejada-Tovar, Candelaria
    Villabona-Ortiz, Angel
    Ortega-Toro, Rodrigo
    APPLIED SCIENCES-BASEL, 2021, 11 (19):