First Screen-Printed Sensor (Electrochemically Activated Screen-Printed Boron-Doped Diamond Electrode) for Quantitative Determination of Rifampicin by Adsorptive Stripping Voltammetry

被引:18
|
作者
Kozak, Jedrzej [1 ]
Tyszczuk-Rotko, Katarzyna [1 ]
Wojciak, Magdalena [2 ]
Sowa, Ireneusz [2 ]
Rotko, Marek [1 ]
机构
[1] Maria Curie Sklodowska Univ Lublin, Fac Chem, Inst Chem Sci, PL-20031 Lublin, Poland
[2] Med Univ Lublin, Dept Analyt Chem, PL-20093 Lublin, Poland
关键词
electrochemically activated screen-printed boron-doped diamond sensor; first screen-printed sensor for rifampicin determination; differential pulse adsorptive stripping voltammetry; river water and urine samples; CARBON ELECTRODES; QUANTIFICATION; SURFACE; PLASMA; FLUID;
D O I
10.3390/ma14154231
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this paper, a screen-printed boron-doped electrode (aSPBDDE) was subjected to electrochemical activation by cyclic voltammetry (CV) in 0.1 M NaOH and the response to rifampicin (RIF) oxidation was used as a testing probe. Changes in surface morphology and electrochemical behaviour of RIF before and after the electrochemical activation of SPBDDE were studied by scanning electron microscopy (SEM), CV and electrochemical impedance spectroscopy (EIS). The increase in number and size of pores in the modifier layer and reduction of charge transfer residence were likely responsible for electrochemical improvement of the analytical signal from RIF at the SPBDDE. Quantitative analysis of RIF by using differential pulse adsorptive stripping voltammetry in 0.1 mol L-1 solution of PBS of pH 3.0 +/- 0.1 at the aSPBDDE was carried out. Using optimized conditions (E-acc of -0.45 V, t(acc) of 120 s, Delta E-A of 150 mV, nu of 100 mV s(-1) and t(m) of 5 ms), the RIF peak current increased linearly with the concentration in the four ranges: 0.002-0.02, 0.02-0.2, 0.2-2.0, and 2.0-20.0 nM. The limits of detection and quantification were calculated at 0.22 and 0.73 pM. The aSPBDDE showed satisfactory repeatability, reproducibility, and selectivity towards potential interferences. The applicability of the aSPBDDE for control analysis of RIF was demonstrated using river water samples and certified reference material of bovine urine.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Extending the limits of screen-printed metallization of phosphorus- and boron-doped surfaces
    Werner, Sabrina
    Lohmueller, Elmar
    Wolf, Andreas
    Clement, Florian
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2016, 158 : 37 - 42
  • [32] Determination of Trace Levels of Nickel(II) by Adsorptive Stripping Voltammetry Using a Disposable and Low-Cost Carbon Screen-Printed Electrode
    Padilla, Victor
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    CHEMOSENSORS, 2021, 9 (05)
  • [33] Electrochemically Reduced Graphene Oxide-Based Screen-Printed Electrodes for Total Tetracycline Determination by Adsorptive Transfer Stripping Differential Pulse Voltammetry
    Lorenzetti, Anabela S.
    Sierra, Tania
    Domini, Claudia E.
    Lista, Adriana G.
    Crevillen, Agustin G.
    Escarpa, Alberto
    SENSORS, 2020, 20 (01)
  • [34] Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode
    Keliskova, Pavlina
    Matvieiev, Oleksandr
    Jirouskova, Eliska
    Sokolova, Romana
    Janikova, Lenka
    Behul, Miroslav
    Selesovska, Renata
    TALANTA, 2025, 281
  • [35] Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
    Dominguez-Renedo, Olga
    Gomez Gonzalez, M. Jesus
    Julia Arcos-Martinez, M.
    SENSORS, 2009, 9 (01) : 219 - 231
  • [36] Stripping coulometry determination of lead and mercury at screen-printed electrodes
    Timofeeva, Daria V.
    Tsapko, Yuriy V.
    Ermakov, Sergey S.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 195 - 199
  • [37] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    El-Attar, Rehab O.
    Hendawy, Hassan A. M.
    Khaled, Elmorsy
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (11) : 3019 - 3029
  • [38] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    Rehab O. El-Attar
    Hassan A. M. Hendawy
    Elmorsy Khaled
    Journal of the Iranian Chemical Society, 2020, 17 : 3019 - 3029
  • [39] Ionic Liquid-Carbon Nanotube Modified Screen-Printed Electrodes and Their Potential for Adsorptive Stripping Voltammetry
    Gan, Patrick
    Foord, John S.
    Compton, Richard G.
    ELECTROANALYSIS, 2014, 26 (09) : 1886 - 1892
  • [40] Simultaneous determination of iron and copper using screen-printed carbon electrodes by adsorptive stripping voltammetry with o-phenanthroline
    Ustabasi, Gul Sirin
    Perez-Rafols, Clara
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    MICROCHEMICAL JOURNAL, 2022, 179