First Screen-Printed Sensor (Electrochemically Activated Screen-Printed Boron-Doped Diamond Electrode) for Quantitative Determination of Rifampicin by Adsorptive Stripping Voltammetry

被引:18
|
作者
Kozak, Jedrzej [1 ]
Tyszczuk-Rotko, Katarzyna [1 ]
Wojciak, Magdalena [2 ]
Sowa, Ireneusz [2 ]
Rotko, Marek [1 ]
机构
[1] Maria Curie Sklodowska Univ Lublin, Fac Chem, Inst Chem Sci, PL-20031 Lublin, Poland
[2] Med Univ Lublin, Dept Analyt Chem, PL-20093 Lublin, Poland
关键词
electrochemically activated screen-printed boron-doped diamond sensor; first screen-printed sensor for rifampicin determination; differential pulse adsorptive stripping voltammetry; river water and urine samples; CARBON ELECTRODES; QUANTIFICATION; SURFACE; PLASMA; FLUID;
D O I
10.3390/ma14154231
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this paper, a screen-printed boron-doped electrode (aSPBDDE) was subjected to electrochemical activation by cyclic voltammetry (CV) in 0.1 M NaOH and the response to rifampicin (RIF) oxidation was used as a testing probe. Changes in surface morphology and electrochemical behaviour of RIF before and after the electrochemical activation of SPBDDE were studied by scanning electron microscopy (SEM), CV and electrochemical impedance spectroscopy (EIS). The increase in number and size of pores in the modifier layer and reduction of charge transfer residence were likely responsible for electrochemical improvement of the analytical signal from RIF at the SPBDDE. Quantitative analysis of RIF by using differential pulse adsorptive stripping voltammetry in 0.1 mol L-1 solution of PBS of pH 3.0 +/- 0.1 at the aSPBDDE was carried out. Using optimized conditions (E-acc of -0.45 V, t(acc) of 120 s, Delta E-A of 150 mV, nu of 100 mV s(-1) and t(m) of 5 ms), the RIF peak current increased linearly with the concentration in the four ranges: 0.002-0.02, 0.02-0.2, 0.2-2.0, and 2.0-20.0 nM. The limits of detection and quantification were calculated at 0.22 and 0.73 pM. The aSPBDDE showed satisfactory repeatability, reproducibility, and selectivity towards potential interferences. The applicability of the aSPBDDE for control analysis of RIF was demonstrated using river water samples and certified reference material of bovine urine.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Electrochemically Activated Screen-Printed Carbon Electrode for Determination of Ibuprofen
    Tyszczuk-Rotko, Katarzyna
    Kozak, Jedrzej
    Wezinska, Anna
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [2] Activated Screen-Printed Boron-Doped Diamond Electrode for Rapid and Highly Sensitive Determination of Curcumin in Food Products
    Kozak, Jedrzej
    Tyszczuk-Rotko, Katarzyna
    Keller, Aleksy
    Wojciak, Magdalena
    Sowa, Ireneusz
    MATERIALS, 2023, 16 (21)
  • [3] Novel Screen-Printed Sensor with Chemically Deposited Boron-Doped Diamond Electrode: Preparation, Characterization, and Application
    Matvieiev, Oleksandr
    Selesovska, Renata
    Vojs, Marian
    Marton, Marian
    Michniak, Pavol
    Hrdlicka, Vojtech
    Hatala, Michal
    Janikova, Lenka
    Chylkova, Jaromira
    Skopalova, Jana
    Cankar, Petr
    Navratil, Tomas
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [4] The Electrochemical Behavior of Nitrazepam at a Screen-Printed Carbon Electrode and Its Determination in Beverages by Adsorptive Stripping Voltammetry
    McGuire, Natasha D.
    Honeychurch, Kevin C.
    Hart, John P.
    ELECTROANALYSIS, 2009, 21 (19) : 2165 - 2170
  • [5] Determination of Pd(II) using an antimony film coated on a screen-printed electrode by adsorptive stripping voltammetry
    Perez-Rafols, Clara
    Trechera, Pedro
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 167 : 1 - 7
  • [6] Effect of Substrate Size on the Electrochemical Properties of Boron-doped Diamond Powders for Screen-printed Diamond Electrode
    Kondo, Takeshi
    Nakajima, Keito
    Osasa, Takahiro
    Kotsugai, Akihiro
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Aikawa, Tatsuo
    Tojo, Toshifumi
    Yuasa, Makoto
    CHEMISTRY LETTERS, 2018, 47 (12) : 1464 - 1467
  • [7] Voltammetric and flow amperometric determination of fungicide cyprodinil in environmental samples using screen-printed sensor with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Borovská, Lucie
    Vagenknecht, Gabriela
    Dušek, Libor
    Behul, Miroslav
    Janíková, Lenka
    Šelešovská, Renáta
    Journal of Environmental Chemical Engineering, 2025, 13 (02):
  • [8] Determination of Nifuroxazide by Flow Injection Linear Adsorptive Stripping Voltammetry on a Screen-Printed Carbon Nanofiber Modified Electrode
    Mozo, J. D.
    Carbajo, J.
    Sturm, J. C.
    Nunez-Vergara, L. J.
    Salgado, P.
    Squella, J. A.
    ELECTROANALYSIS, 2012, 24 (03) : 676 - 682
  • [9] Simple and Sensitive Determination of Sibutramine in Slimming Tea Beverages Using a Carbon Screen-printed Electrode with Adsorptive Stripping Voltammetry
    Lima, Amanda B.
    dos Santos, Wallans T. P.
    Compton, Richard G.
    ELECTROANALYSIS, 2019, 31 (05) : 975 - 980
  • [10] Determination of Sb(III) using an ex-situ bismuth screen-printed carbon electrode by adsorptive stripping voltammetry
    Rojas-Romo, Carlos
    Serrano, Nuria
    Arino, Cristina
    Arancibia, Veronica
    Manuel Diaz-Cruz, Jose
    Esteban, Miguel
    TALANTA, 2016, 155 : 21 - 27