Power versus conventional color Doppler sonography: Comparison in the depiction of vasculature in liver tumors

被引:137
|
作者
Choi, BI
Kim, TK
Han, JK
Chung, JW
Park, JH
Han, MC
机构
[1] Seoul National University, College of Medicine, Seoul National University Hospital, Chongno-Gu, Seoul, 110-744, 28, Yongon-Dong
关键词
liver neoplasms; blood supply; US; ultrasound; (US); comparative studies; Doppler studies;
D O I
10.1148/radiology.200.1.8657945
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare power and conventional color Doppler sonography in the depiction of the intratumoral vasculature of hemangiomas, hepatocellular carcinomas (HCCs), and metastases of the liver. MATERIALS AND METHODS: Thirty-two patients with liver tumors (12 hemangiomas, 11 HCCs, and nine metastases) were prospectively evaluated with power and conventional color Doppler sonography by using a 2-4-MHz convex probe with 2-MHz Doppler frequency. Power Doppler sonography was performed with a 75%-88% gain Conventional color Doppler sonography was performed with a 55%-75% gain and a pulse repetition frequency of 700 Hz. Power Doppler signals and color Doppler signals interrogated in one plane were analyzed by two radiologists, who subjectively rated power Doppler sonography as superior, equal, or inferior to color Doppler sonography. RESULTS: Overall, power Doppler sonography was superior to color Doppler sonography in 18 patients and equal in 14 (P < .01). In hemangiomas, power Doppler sonography was superior to color Doppler sonography in 10 patients and equal in two (P < .01). In HCCs, power Doppler sonography was superior to color Doppler sonography in four patients and equal in seven (P > .05). In metastases, power Doppler sonography was superior to color Doppler sonography in four patients and equal in five (P < .05). CONCLUSION: Power Doppler sonography is more sensitive than color Doppler sonography in the depiction of the vasculature of Liver tumors, particularly in hemangiomas.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 50 条
  • [11] Conventional color Doppler velocity sonography versus color Doppler energy sonography for the diagnosis of acute experimental torsion of the spermatic cord
    Lee, FT
    Winter, DB
    Madsen, FA
    Zagzebski, JA
    Pozniak, MA
    Chosy, SG
    Scanlan, KA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 785 - 790
  • [12] Comparison of tissue harmonic imaging sonography and conventional sonography in liver tumors
    Vilgrain, V
    Holst, N
    Vullierme, M
    Denys, AL
    Abehsera, MM
    Menu, YM
    RADIOLOGY, 1999, 213P : 211 - 211
  • [13] Power and color Doppler sonography
    Schmidt, W
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 : 47 - 47
  • [14] Color and power Doppler sonography of liver hemangiomas: A dream unfulfilled?
    Perkins, AB
    Imam, K
    Smith, WJ
    Cronan, JJ
    JOURNAL OF CLINICAL ULTRASOUND, 2000, 28 (04) : 159 - 165
  • [15] COLOR DOPPLER SONOGRAPHY FOR TUMORS OF THE BREAST
    LUSKA, G
    LOTT, D
    RISCH, U
    VONBOETTICHER, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (02): : 142 - 145
  • [16] Value of color Doppler sonography in the preoperative planning of resection of liver tumors
    Bunk, A
    Stoelben, E
    Kohler, T
    Nagel, M
    Seager, HD
    EFFICIENCY AND ECONOMICS OF CLINICAL CARE AND RESEARCH IN SURGERY, 1997, SUPPL : 428 - 430
  • [17] COMPARISON OF COLOR DOPPLER ENERGY SONOGRAPHY WITH CONVENTIONAL COLOR DOPPLER SONOGRAPHY IN DETECTION OF FLOW SIGNAL IN PERIPHERAL RENAL-TRANSPLANT VESSELS
    PREIDLER, KW
    SZOLAR, DM
    UGGOWITZER, M
    STISKAL, M
    HORINA, J
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814): : 1103 - 1105
  • [18] COLOR-CODED DOPPLER SONOGRAPHY OF PRIMARY AND SECONDARY LIVER-TUMORS
    BORNER, N
    CLEMENT, T
    HERZOG, P
    KREITNER, KF
    MILTENBERGER, H
    SCHILD, H
    MEYER, J
    ULTRASCHALL IN DER MEDIZIN, 1990, 11 (06): : 274 - 280
  • [19] Evaluation of contrast enhanced color Doppler sonography in the differential diagnosis of liver tumors
    Strobel, D
    Becker, D
    Krodel, U
    Martus, P
    Hahn, EG
    RADIOLOGY, 1998, 209P : 232 - 232
  • [20] Color Doppler Sonography of Extradigital Glomus Tumors
    Catalano, Orlando
    Alfageme Roldan, Fernando
    Solivetti, Francesco Maria
    di Santolo, Maria Scotto
    Bouer, Marcio
    Wortsman, Ximena
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (01) : 231 - 238