Effects of outlet subcoolings and heat generation rates on transient critical heat flux for subcooled flow boling of water in a vertical tube

被引:7
|
作者
Shibahara, M. [1 ]
Fukuda, K. [1 ]
Liu, Q. S. [1 ]
Hata, K. [1 ]
机构
[1] Kobe Univ, Grad Sch Maritime Sci, Higashinada Ku, 5-1-1Fukaeminamimachi, Kobe, Hyogo 6580022, Japan
基金
日本学术振兴会;
关键词
MODELS; CONVECTION; PRESSURE; STEADY; DESIGN; CHF;
D O I
10.1007/s00231-017-2036-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
Critical heat fluxes (CHFs) for subcooled flow boiling of water in a vertical tube due to steady and exponentially heat inputs were measured. The platinum tube with an inner diameter of 2.0 mm and a length of 94.8 mm was placed vertically in the experimental water loop. The upward flow velocity was approximately 2.5 m/s and the outlet subcooling ranged from 18 to 48 K. The heat generation rate was varied exponentially to investigate the effect of e-folding time on the CHFs. As an experimental result, the CHFs increased with a decrease in the e-folding time. When the e-folding times were longer, the CHFs were almost constant, whereas the CHFs increased for shorter e-folding times. The CHFs were independent on outlet subcoolings at low flow conditions. Moreover, it was considered that the explosive-like CHF occurred when the inner surface temperature of the tube exceeded the lower limit of heterogeneous spontaneous nucleation (HSN) temperature.
引用
收藏
页码:2999 / 3012
页数:14
相关论文
共 50 条
  • [31] Prediction of critical heat flux for subcooled flow boiling
    Liu, W
    Nariai, H
    Inasaka, F
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (18) : 3371 - 3390
  • [32] The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux
    DolatiAsl, K.
    Bakhshan, Y.
    Abedini, E.
    Niazi, S.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2020, 33 (08): : 1590 - 1597
  • [33] Correlation of high critical heat flux during flow boiling for water in a small tube at various subcooled conditions
    Shibahara, M.
    Fukuda, K.
    Liu, Q. S.
    Hata, K.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 82 : 74 - 80
  • [34] THE PREDICTION OF THE CRITICAL HEAT-FLUX IN WATER-SUBCOOLED FLOW BOILING
    CELATA, GP
    CUMO, M
    MARIANI, A
    ZUMMO, G
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1995, 38 (06) : 1111 - 1119
  • [35] Heat transfer and critical heat flux of subcooled water flow boiling in a SUS304-tube with twisted-tape insert
    Hata K.
    Masuzaki S.
    Journal of Thermal Science and Engineering Applications, 2011, 3 (01)
  • [36] HEAT TRANSFER AND CRITICAL HEAT FLUX OF SUBCOOLED WATER FLOW BOILING IN A SUS304-TUBE WITH TWISTED-TAPE INSERT
    Hata, Koichi
    Masuzaki, Suguru
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 1: BIO HEAT TRANSFER, BOILING HEAT TRANSFER, COMPUTATIONAL HEAT TRANSFER, 2010, : 201 - 213
  • [37] Critical heat fluxes of subcooled water flow boiling in a short vertical tube at high liquid Reynolds number
    Hata, Koichi
    Masuzaki, Suguru
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (10) : 3145 - 3157
  • [38] EFFECTS OF UPSTREAM COMPRESSIBILITY ON SUBCOOLED CRITICAL HEAT FLUX
    DALEAS, RS
    BERGLES, AE
    MECHANICAL ENGINEERING, 1966, 88 (01) : 81 - &
  • [39] Effects of mechanical vibration on critical heat flux in vertical annulus tube
    Kim, Dae Hun
    Lee, Yong Ho
    Chang, Soon Heung
    NUCLEAR ENGINEERING AND DESIGN, 2007, 237 (09) : 982 - 987
  • [40] Effects of spray characteristics on critical heat flux in subcooled water spray cooling
    Chen, RH
    Chow, LC
    Navedo, JE
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (19) : 4033 - 4043