An artificial neural network for GFR estimation in the DCE-MRI studies of the kidneys

被引:0
|
作者
Strzelecki, Michal [1 ]
Klepaczko, Artur [1 ]
Muszelska, Martyna [1 ]
Eikefjord, Eli [2 ]
Rorvik, Jarle [3 ]
Lundervold, Arvid [4 ]
机构
[1] Lodz Univ Technol, Inst Elect, Lodz, Poland
[2] Haukeland Hosp, Dept Radiol, Bergen, Norway
[3] Univ Bergen, Dept Clin Med, Bergen, Norway
[4] Univ Bergen, Dept Biomed, Bergen, Norway
关键词
dynamic contrast-enhanced MRI; artificial neural networks; pharmacokinetic modeling; parameter estimation; GLOMERULAR-FILTRATION-RATE; PERFUSION;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The dynamic contrast-enhanced magnetic resonance imaging is a diagnostic method directed at estimation of renal performance. Analysis of the image intensity time-courses in the renal cortex and parenchyma enables quantification of the kidney filtration characteristics. A standard approach used for that purpose involves fitting a pharmacokinetic model to image data and optimizing a set of model parameters. It is essentially a multi-objective and non-linear optimization problem. Standard methods applied in such scenarios include nonlinear least-squares (NLS) algorithms, such as Levenberg-Marquardt or Trust Region Reflective methods. The major disadvantage of these classical approaches is the requirement for determining the starting point of the optimization, whose final result is a local minimum of the objective function. On the contrary, artificial neural networks (ANN) are trained based on a large range of parameter combinations, potentially covering whole solution space. Thus, they appear particularly useful in fitting complex, non-linear, multi-parametric relationships to the observed noisy data and offer greater ability to detect all possible interactions between predictor variables without the need for explicit statistical formulation. In this paper we compare the ANN and NLS approaches in application to measuring perfusion based on DCE-MR images. The experiments performed on a dataset containing 10 dynamic image series collected for 5 healthy volunteers proved superior performance of the neural networks over classical methods in terms of quantifying true perfusion parameters, robustness to noise and varying imaging conditions.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 50 条
  • [41] Segmentation-Driven Image Registration-Application to 4D DCE-MRI Recordings of the Moving Kidneys
    Hodneland, Erlend
    Hanson, Erik A.
    Lundervold, Arvid
    Modersitzki, Jan
    Eikefjord, Eli
    Munthe-Kaas, Antonella Z.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2014, 23 (05) : 2392 - 2404
  • [42] A Recurrent Two-Stage Anatomy-Guided Network for Registration of Liver DCE-MRI
    Shen, Wenjun
    Chen, Liyun
    Wei, Dongming
    Qiao, Yuanfang
    Zhan, Yiqiang
    Shen, Dinggang
    Wang, Qian
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2021, 2021, 12966 : 219 - 227
  • [43] A contrastive learning-based neural network to synthesize cell subpopulation features from DCE-MRI for predicting prognosis in breast cancer
    Ge, Yuanyuan
    Fan, Ming
    Li, Xian
    Liu, Yueyue
    Li, Lihua
    IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, MEDICAL IMAGING 2024, 2024, 12931
  • [44] Automatic alignment of renal DCE-MRI image series for improvement of quantitative tracer kinetic studies
    Zikic, Darko
    Sourbron, Steven
    Feng, Xinxing
    Michaely, Henrik J.
    Khamene, Ali
    Navab, Nassir
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [45] Improving Hypoxia Map Estimation by Using Model-Free Classification Techniques in DCE-MRI Images
    Venianaki, M.
    Kontopodis, E.
    Nikiforaki, K.
    de Bree, E.
    Maris, T.
    Karantanas, A.
    Salvetti, O.
    Marias, K.
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2016, : 183 - 188
  • [46] Improved Bolus Arrival Time and Arterial Input Function Estimation for Tracer Kinetic Analysis in DCE-MRI
    Singh, Anup
    Rathore, Ram K. Singh
    Haris, Mohammad
    Verma, Sanjay K.
    Husain, Nuzhat
    Gupta, Rakesh K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) : 166 - 176
  • [47] Deep Convolutional Neural Networks-Based Automatic Breast Segmentation and Mass Detection in DCE-MRI
    Jiao, Han
    Jiang, Xinhua
    Pang, Zhiyong
    Lin, Xiaofeng
    Huang, Yihua
    Li, Li
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2020, 2020 (2020)
  • [48] Single-Channel Blind Estimation of Arterial Input Function and Tissue Impulse Response in DCE-MRI
    Taxt, Torfinn
    Jirik, Radovan
    Rygh, Cecilie Brekke
    Gruner, Renate
    Bartos, Michal
    Andersen, Erling
    Curry, Fitz-Roy
    Reed, Rolf K.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (04) : 1012 - 1021
  • [49] Greybox: A hybrid algorithm for direct estimation of tracer kinetic parameters from undersampled DCE-MRI data
    Rastogi, Aditya
    Yalavarthy, Phaneendra Kumar
    MEDICAL PHYSICS, 2024, 51 (07) : 4838 - 4858
  • [50] Computer-based automated estimation of breast vascularity and correlation with breast cancer in DCE-MRI images
    Kostopoulos, Spiros A.
    Vassiou, Katerina G.
    Lavdas, Eleftherios N.
    Cavouras, Dionisis A.
    Kalatzis, Ioannis K.
    Asvestas, Pantelis A.
    Arvanitis, Dimitrios L.
    Fezoulidis, Ioannis V.
    Glotsos, Dimitris T.
    MAGNETIC RESONANCE IMAGING, 2017, 35 : 39 - 45