Size characterization and quanti fication of titanium dioxide nano- and microparticles-based products by Asymmetrical Flow Field -Flow Fractionation coupled to Dynamic Light Scattering and Inductively Coupled Plasma Mass Spectrometry

被引:16
|
作者
Ojeda, David [1 ]
Vanesa Taboada-Lopez, Maria [2 ]
Bolea, Eduardo [1 ]
Perez-Arantegui, Josefina [1 ]
Bernejo-Barrera, Pilar [2 ]
Moreda-Pineiro, Antonio [2 ]
Laborda, Francisco [1 ]
机构
[1] Univ Zaragoza, Inst Environm Sci IUCA, Grp Analyt Spect & Sensors GEAS, Pedro Cerbuna 12, Zaragoza 50009, Spain
[2] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Trace Element Spect & Speciat Grp GETEE,Strateg G, Ave Ciencias S-N, Santiago De Compostela 15782, Spain
关键词
TIO2; NANOPARTICLES; OXIDE NANOPARTICLES; ROUTINE ANALYSIS; ICP-AES; FOOD; QUANTIFICATION; OPTIMIZATION; SUNSCREENS; PARTICLES; PROSPECTS;
D O I
10.1016/j.aca.2020.04.080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the size characterization and quantification of titanium dioxide (TiO2) nano- and microparticles by Asymmetric Flow Field-Flow Fractionation (AF4) coupled to Dynamic Light Scattering (DLS) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is described. Different strategies for size characterization with size standards and the use of the DLS signal for the estimation of hydrodynamic diameters are evaluated. The procedure has been applied to the characterization of TiO2 nanoparticles in photocatalytic products and crab sticks (surimis), where TiO2 is present as E171 food additive. Sizes in the range of 50–90 nm and 160–170 nm were estimated in the different photocatalytic products by AF4-DLS, in good agreement with the sizes predicted by calibration versus SiO2 and polystyrene standards. In surimis, sizes between 140 and 350 nm were estimated by AF4-DLS, similar to those reported in literature for E171 additive. These results were also compared to those obtained by single particle ICP-MS, which allowed the detection of a nano-sized fraction of TiO2 present in the four surimis analyzed. Titanium contents in one of the photocatalytic products determined by AF4-ICP-MS was 16.86 ± 2.54 mg g−1, whereas the alkaline extraction followed by AF4-ICP-MS allowed the determination of TiO2 content in four surimis at concentration levels in the range of the μg g−1 (from 3.14 ± 0.10 to 14.55 ± 1.46 μg Ti g−1), with channel recoveries above 85% in all cases. The method has been validated by comparison with the Ti content determined by ICP-OES after microwaved assisted acid digestion of all the samples. The methodology proposed allows the complete quantification of the (nano)particulate forms of titanium in complex matrices together with their size characterization. © 2020 Elsevier B.V.
引用
收藏
页码:20 / 30
页数:11
相关论文
共 50 条
  • [41] Detection and characterization of silver nanoparticles in aqueous matrices using asymmetric-flow field flow fractionation with inductively coupled plasma mass spectrometry
    Hoque, Md Ehsanul
    Khosravi, Kambiz
    Newman, Karla
    Metcalfe, Chris D.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 : 109 - 115
  • [42] Development of sedimentation field-flow fractionation-inductively coupled plasma mass-spectrometry for the characterization of environmental colloids
    Ranville, JF
    Chittleborough, DJ
    Shanks, F
    Morrison, RJS
    Harris, T
    Doss, F
    Beckett, R
    ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) : 315 - 329
  • [43] Flow field-flow fractionation-inductively coupled plasma mass spectrometry and metal speciation in proteins: A feasibility study
    Siripinyanond, A
    Barnes, RM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1527 - 1531
  • [44] Measuring sorption of metals to nanoparticles using flow field-flow-fractionation-inductively coupled plasma-mass spectrometry
    Lesher, Emily K.
    Ranville, J. F.
    Honeyman, Bruce D.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237
  • [45] Multielement characterization of metal-humic substances complexation by size exclusion chromatography, asymmetrical flow field-flow fractionation, ultrafiltration and inductively coupled plasma-mass spectrometry detection: A comparative approach
    Bolea, E.
    Gorriz, M. P.
    Bouby, M.
    Laborda, F.
    Castillo, J. R.
    Geckeis, H.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1129 (02) : 236 - 246
  • [46] Evaluation of different strategies for determination of selenomethionine (SeMet) in selenized yeast by asymmetrical flow field flow fractionation coupled to inductively coupled plasma mass spectrometry (AF4-ICP-MS)
    Alcantara, Daniel B.
    Nascimento, Ronaldo F.
    Lopes, Gisele S.
    Grinberg, Patricia
    ANALYTICAL METHODS, 2020, 12 (26) : 3351 - 3360
  • [47] A method based on asymmetric flow field flow fractionation hyphenated to inductively coupled plasma mass spectrometry for the monitoring of platinum nanoparticles in water samples
    Sanchez-Cachero, Armando
    Lopez-Sanz, Sara
    Farinas, Nuria Rodriguez
    Rios, Angel
    Martin-Doimeadios, Rosa del Carmen Rodriguez
    TALANTA, 2021, 222
  • [48] Flow field-flow fractionation hyphenated with inductively coupled plasma mass spectrometry: a robust technique for characterization of engineered elemental metal nanoparticles in the environment
    Bai, Qingsheng
    Yin, Yongguang
    Liu, Yanwanjing
    Jiang, Haowen
    Wu, Mengxin
    Wang, Weidong
    Tan, Zhiqiang
    Liu, Jingfu
    Moon, Myeong Hee
    Xing, Baoshan
    APPLIED SPECTROSCOPY REVIEWS, 2023, 58 (02) : 110 - 131
  • [49] Size -resolved analysis of trace elements in the dissolved fraction (<0.45 μm) of soil solutions using a novel lysimeter and asymmetrical flow field-flow fractionation coupled to ultraviolet absorbance and inductively coupled plasma mass spectrometry
    Du, L.
    Cuss, C. W.
    Dyck, M. F.
    Noernberg, T.
    Shotyk, W.
    CANADIAN JOURNAL OF SOIL SCIENCE, 2020, 100 (04) : 381 - 392
  • [50] Ultrahigh molar mass component detected in ethylhydroxyethyl cellulose by asymmetrical flow field-flow fractionation coupled to multiangle light scattering
    Andersson, M
    Wittgren, B
    Wahlund, KG
    ANALYTICAL CHEMISTRY, 2001, 73 (20) : 4852 - 4861