Post-installed shear connectors: Fatigue push-out tests of coiled spring pins

被引:4
|
作者
Hallmark, Robert [1 ,2 ]
Collin, Peter [1 ,3 ]
Hicks, Stephen J. [4 ]
机构
[1] Lulea Univ Technol, Lulea, Sweden
[2] Swedish Transport Adm, Lulea, Sweden
[3] Ramboll, Lulea, Sweden
[4] Heavy Engn Res Assoc, Auckland, New Zealand
关键词
Push-out test; Fatigue; Coiled spring pin; Shear studs; Strengthening; Shear connector; Post installation; Composite; Steel; Concrete; COMPOSITE BEAMS; PART I; STEEL; BEHAVIOR; RESISTANCE; CONCRETE; DESIGN; STUDS;
D O I
10.1016/j.jcsr.2018.10.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The number of heavy vehicles and their weight have been increasing over time, implying that many bridges are experiencing traffic loads with higher magnitude and frequency than they were originally designed for. In some cases, it will be necessary to either replace or strengthen the structures to keep the bridges in service. For existing non-composite steel girder bridges, post-installation of shear connectors can often be used to increase the traffic load capacity significantly. One type of shear connector that is suitable for post-installation, even though not commonly used, is the Coiled Spring Pin. These interference fit connectors can be installed from below the bridge deck during traffic, in order to minimize the impact on road users. This paper describes an experimental study on the fatigue strength of Coiled Spring Pins and a compilation of previously performed fatigue tests on this type of connector. The new test series, with nine specimens, are evaluated statistically and a fatigue strength design equation is proposed. The results show that there are large variations between different test series, while tests within the same series show good agreement The reasons for this are discussed in the paper along with recommendations for future testing. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:298 / 309
页数:12
相关论文
共 50 条
  • [41] Push-out test of square CFST columns with steel plate shear connectors
    Qiao Q.
    Zhang W.
    Cao W.
    Dong H.
    2018, Huazhong University of Science and Technology (46): : 108 - 115
  • [42] Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams
    Bamaga, S. O.
    Tahir, M. M.
    Tan, C. S.
    Shek, P. N.
    Aghlara, R.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 223 : 288 - 298
  • [43] Push-Out Tests on Large Diameter and High Strength Welded Stud Connectors
    Yang, Fei
    Liu, Yuqing
    Li, Yongjun
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [44] Shakedown Behavior of a Continuous Steel Bridge Girder Strengthened With Post-Installed Shear Connectors
    Kreitman, Kerry
    Azad, Amir Reza Ghiami
    Engelhardt, Michael
    Helwig, Todd
    Williamson, Eric
    STRUCTURES, 2016, 8 : 245 - 251
  • [45] Ultimate Shear Resistance of Perfobond Rib Shear Connectors Based on a Modified Push-Out Test
    Wang, Zhenhai
    Li, Qiao
    Zhao, Canhui
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (04) : 667 - 680
  • [46] Bending Shear Tests on R/C-Beams with Post-Installed Shear Reinforcement
    Randl, Norbert
    Kunz, Jakob
    BETON- UND STAHLBETONBAU, 2009, 104 (11) : 728 - 736
  • [47] Push-out Tests of Innovative Shear Connectors Between Cold-formed Steel Section Integrated with Ferrocement Jacket
    Alenezi, K.
    Tahir, M. M.
    Alhajri, T.
    Badr, M. R. K.
    Mirza, J.
    Lawan, M. M.
    Hosseinpour, E.
    JURNAL TEKNOLOGI, 2015, 74 (04): : 67 - 72
  • [48] Experimental study of static and fatigue push-out test on headed stud shear connectors in UHPC composite steel beams
    Gyawali, Mohit
    Sennah, Khaled
    Ahmed, Mizan
    Hamoda, Ahmed
    STRUCTURES, 2024, 70
  • [49] Experimental Analysis of the Mechanical Behavior of Shear Connectors for Precast Sandwich Wall Panels When Subjected to the Push-Out Tests
    Silva, John Kennedy Fonseca
    Lameiras, Rodrigo de Melo
    BUILDINGS, 2024, 14 (10)
  • [50] Effect of additional constraints of push-out test on the mechanical properties of perfobond shear connectors
    Zou, Yang
    Peng, Hongbo
    Zhang, Zhongya
    Jiang, Jinlong
    Guo, Jincen
    STRUCTURES, 2023, 47 : 991 - 1004