Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

被引:4
|
作者
Miller, Marcelo E. [1 ]
Sztejnberg, Manuel L. [1 ]
Gonzalez, Sara J. [1 ,2 ]
Thorp, Silvia I. [1 ]
Longhino, Juan M. [1 ]
Estryk, Guillermo [1 ]
机构
[1] Comis Nacl Energia Atom, RA-1429 Buenos Aires, DF, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
SPND; BNCT; on-line flux measurement; DOSIMETRY; REACTOR;
D O I
10.1118/1.3660204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 +/- 0.05 x 10(-21) A n(-1).cm(2).s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3660204]
引用
收藏
页码:6502 / 6512
页数:11
相关论文
共 50 条
  • [21] Allowance for the burnup of a rhodium self-powered neutron detector in a VVER-1000 reactor
    Kurchenkov, A. Yu
    Kovel', A. I.
    Khvatov, V. A.
    Chapaev, V. M.
    PHYSICS OF ATOMIC NUCLEI, 2013, 76 (13) : 1586 - 1594
  • [22] Allowance for the burnup of a rhodium self-powered neutron detector in a VVER-1000 reactor
    A. Yu. Kurchenkov
    A. I. Kovel’
    V. A. Khvatov
    V. M. Chapaev
    Physics of Atomic Nuclei, 2013, 76 : 1586 - 1594
  • [23] Numerical Simulation and Sensitivity Study of the Rhodium Self-Powered Neutron Detector Used in PWR
    Cao, Liangzhi
    Li, Zhuo
    Wu, Hongchun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (04) : 742 - 751
  • [24] A study on the sensitivity of Self-Powered Neutron Detector (SPND)
    Lee, W
    Cho, G
    Kim, K
    Kim, HJ
    Choi, Y
    Park, MK
    Kim, S
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 772 - 776
  • [25] ACTIVATION COMPONENT OF THE RESPONSE OF A SELF-POWERED NEUTRON DETECTOR TO THERMAL AND EPITHERMAL NEUTRONS
    ERBEN, O
    SOVIET ATOMIC ENERGY, 1979, 46 (05): : 402 - 406
  • [26] SELF-POWERED NEUTRON DETECTORS FOR REACTOR FLUX MONITORING
    HILBORN, JW
    NUCLEONICS, 1964, 22 (02): : 69 - &
  • [27] Study of neutron sensitivity for vanadium self-powered neutron detector in nuclear reactors
    Wu, Xiong
    Cai, Li
    Zhang, Xiangju
    Wu, Tingyu
    Jiang, Jieqiong
    AIP ADVANCES, 2023, 13 (12)
  • [28] POSSIBILITY OF NEUTRON-SPECTRA FLUX MEASUREMENT BY SELF-POWERED NEUTRON DETECTORS
    KIRSANOV, VS
    BABULEVI.EN
    ROZENBLY.ND
    SHIPOVSK.YM
    ZAGADKIN, VA
    MITELMAN, MG
    ATOMNAYA ENERGIYA, 1972, 32 (01): : 65 - +
  • [29] Simulation study of a rhodium self-powered neutron detector for irradiation of nuclear fuel and material reactor
    Zhou, Dianwei
    Li, Zhan
    Yang, Aixiang
    Xiao, Ren
    Guo, Zhiqi
    Zhang, Yuanji
    Zhu, Dingjun
    Shao, Jianxiong
    Chen, Ximeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1060
  • [30] IDENTIFICATION OF THE METROLOGICAL PARAMETERS OF THE RHODIUM SELF-POWERED NEUTRON DETECTORS
    BOUZHIK, Y
    BORLIK, E
    GADOMSKI, A
    LYATEK, S
    SUICHINSKA, M
    TOPA, E
    KHVASHCHEVSKI, S
    KASCHIEV, G
    GEORGIEV, B
    MARINOV, I
    ALEKSANDROV, G
    NUKLEONIKA, 1980, 25 (09) : 1143 - 1161