UV-LED fluence determination by numerical method for microbial inactivation studies

被引:16
|
作者
Keshavarzfathy, Majid [1 ]
Malayeri, Adel Haji [1 ]
Mohseni, Madjid [1 ]
Taghipour, Fariborz [1 ]
机构
[1] Univ British Columbia, Dept Chem & Biol Engn, 2360 East Mall, Vancouver, BC V6T 1Z3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
UV-LED; Irradiation model; Fluence determination; Polychromatic; Kinetic rate constant; Mathematical model; LIGHT-EMITTING-DIODES; WATER DISINFECTION; REACTOR; WAVELENGTH; DEPENDENCE;
D O I
10.1016/j.jphotochem.2020.112406
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Ultraviolet Light-Emitting Diode (UV-LED) is a new UV source suitable for small to mid-size water disinfection units. The design of a UV-LED reactor entails the integration of hydrodynamics, radiation, and kinetics data. The kinetics of microbial inactivation are necessary for UV-LED reactor design and the determination of kinetic rate constants depends on the accuracy of fluence rate measurement. However, there is not an easy way to measure the fluence rate inside a solution. In this study, a computational method is proposed to calculate irradiance and fluence rate based on the LED's relative radiation profile and its radiant power, which are two standard pieces of information available in an LED's datasheet. UV-LED was modeled as a polychromatic point source with a specific radiation profile and the fluence rate was calculated by solving the Radiative Transfer Equation by considering the refraction, reflection, and absorption of the medium. The irradiance and fluence rate predictions on the surface of the water were evaluated successfully by radiometry and actinometry measurements, respectively. The fluence rate imposed by 265-nm UV-LED and 275-nm UV-LED in Petri dishes with internal diameters of 5 cm and 9 cm were measured using biodosimetry with E. coli and MS2, when the UV-LED germicidal factor was obtained by considering the LED emission spectrum and the microorganism action spectra. Biodosimetry experiments using E. coli and MS2 at exposure times over 200 s indicated a close agreement between the simulation and experimental data. Such results are indicating the kinetic rate constants of a microorganism can be estimated without performing kinetic study using the action spectrum of microorganisms. Further, the results showed the proposed method can be applied for fluence rate determination for any LED's radiation profile, LED position, and the experimental apparatus's regardless of the availability of the action spectrum of microorganisms.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Performance of UV-LED and UV-C treatments for the inactivation of Escherichia coli ATCC 25922 in food model solutions: Influence of optical and physical sample characteristics
    Pihen, Christelle
    Mani-Lopez, Emma
    Franco-Vega, Avelina
    Jimenez-Munguia, Maria Teresa
    Lopez-Malo, Aurelio
    Ramirez-Corona, Nelly
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2023, 85
  • [42] Comparison of UV-LED treatments at 255 and 281 nm in continuous-flow on bacterial inactivation, quality, nutrients and electrical efficiency in beverages
    Popovic, Vladimir
    Reman, Julia
    Koutchma, Tatiana
    JOURNAL OF FOOD ENGINEERING, 2023, 357
  • [43] Virtual prototyping and characterization of a point-of-entry UV-LED water disinfection reactor with the synergic effect of radiation, hydrodynamics, and inactivation kinetics
    Montazeri, Mahyar Mohaghegh
    Taghipour, Fariborz
    WATER RESEARCH, 2023, 230
  • [44] Inactivation of Listeria monocytogenes and Salmonella Typhimurium in beef broth and on diced beef using an ultraviolet light emitting diode (UV-LED) system
    McSharry, Siobhan
    Koolman, Leonard
    Whyte, Paul
    Bolton, Declan
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2022, 158
  • [45] A dynamic equilibrium method for the SnO2-based ozone sensors using UV-LED continuous irradiation
    Jeng, Chien-Chung
    Chong, Paul J. H.
    Chiu, Cheng-Chung
    Jiang, Guo-Jhen
    Lin, Hung-Ju
    Wu, Ren-Jang
    Wu, Chiu-Hsien
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 702 - 706
  • [46] A Potential New Method for Determination of the Fluence (UV Dose) Delivered in UV Reactors Involving the Photodegradation of Free Chlorine
    Feng, Yangang
    Smith, Daniel W.
    Bolton, James R.
    WATER ENVIRONMENT RESEARCH, 2010, 82 (04) : 328 - 334
  • [47] Development of a geometrical model for the determination of the average intensity in a flow-through UV-LED reactor and validation with biodosimetry and actinometry
    Romero-Martinez, Leonardo
    Moreno-Andres, Javier
    Acevedo-Merino, Asuncion
    Nebot, Enrique
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 49
  • [48] Susceptibility of enveloped and non-enveloped viruses to ultraviolet light-emitting diode (UV-LED) irradiation and implications for virus inactivation mechanisms
    Canh, Vu Duc
    Yasui, Midori
    Torii, Shotaro
    Oguma, Kumiko
    Katayama, Hiroyuki
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2023, 9 (09) : 2283 - 2292
  • [49] Computer numerical control (CNC) lithography: light-motion synchronized UV-LED lithography for 3D microfabrication
    Kim, Jungkwun
    Yoon, Yong-Kyu
    Allen, Mark G.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (03)
  • [50] Nano-TiO2 catalyzed UV-LED sample pretreatment method for decomposition of humic substances in natural water samples
    Havia, Johanna
    Niemela, Matti
    Peramaki, Paavo
    MICROCHEMICAL JOURNAL, 2017, 133 : 645 - 649