An evaluation of the performance of an uncooled microbolometer array infrared camera for transient thermography NDE

被引:22
|
作者
Pickering, S. G. [1 ]
Almond, D. P. [1 ]
机构
[1] Univ Bath, UK Res Ctr NDE, Dept Engn Mech, Bath BA2 7AY, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
transient thermography; NDE; FPA; SNR;
D O I
10.1080/10589750701446484
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Transient thermography images of artificial defects in a carbon fibre composite test piece obtained using a cooled focal plane array (FPA) infrared camera are compared with those obtained using an un-cooled microbolometer array camera. Signal to noise ratios of each defect image are computed to provide an objective comparison of the performances of the two cameras. The cooled FPA infrared camera exhibits a higher ultimate defect detection capability than the un-cooled microbolometer array camera but this camera has the advantages of much smaller size and lower cost.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [31] PERFORMANCE OF AN ASTRONOMICAL INFRARED ARRAY CAMERA SPECTROMETER
    BARTON, J
    ALLEN, D
    GILLINGHAM, P
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 147 - 154
  • [32] Transient thermal simulation of uncooled microbolometer detectors and their performance analysis - art. no. 64234S
    Zhang Junju
    Sun Lianjun
    Chang Benkang
    Qian Yunsheng
    Qiu Yafeng
    Si, Tian
    INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, PTS 1-3, 2007, 6423 : S4234 - S4234
  • [33] Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
    Cantor, M. C.
    Goetz, H. M.
    Beattie, K.
    Renaud, D. L.
    JDS COMMUNICATIONS, 2022, 3 (05):
  • [34] Infrared Sensing With Self-Supporting YBCO Uncooled IR Microbolometer Array Integrated With On-Chip CCBDI Readout Circuit
    Kumar, Sandeep
    Butler, Donald P.
    IEEE SENSORS JOURNAL, 2009, 9 (04) : 411 - 418
  • [35] The non-uniformity measurement and image processing algorithm evaluation for uncooled microbolometer infrared focal plane arrays
    Qian, YS
    Chang, BK
    Zhang, JJ
    Xing, SX
    Yu, SZ
    Yang, J
    INFRARED COMPONENTS AND THEIR APPLICATIONS, 2005, 5640 : 117 - 123
  • [36] A FACET ENSEMBLE APPROACH FOR EVALUATION OF ARRAY PERFORMANCE IN ULTRASONIC NDE
    MCGARRITY, JP
    HAYWARD, G
    POWELL, DJ
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (01) : 19 - 25
  • [37] Noise Performance Evaluation of Uncooled Infrared Detectors (June 2009)
    Oloomi, Hossein M.
    Alam, Mohammad S.
    Rana, Mukti M.
    IEEE SENSORS JOURNAL, 2011, 11 (04) : 971 - 987
  • [38] Performance enhancement of uncooled infrared focal plane array by integrating metamaterial absorber
    Ma, Wei
    Wen, Yongzheng
    Yu, Xiaomei
    Feng, Yun
    Zhao, Yuejin
    APPLIED PHYSICS LETTERS, 2015, 106 (11)
  • [39] Evaluation of Defect and Performance in Thermoelectric Modules by Infrared Thermography
    Cho, Young Tae
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2018, 38 (02) : 83 - 90
  • [40] Antenna-coupled microbolometer based uncooled 2D array and camera for 2D real-time terahertz imaging
    Simoens, F.
    Meilhan, J.
    Gidon, S.
    Lasfargues, G.
    Dera, J. Lalanne
    Ouvrier-Buffet, J. L.
    Pocas, S.
    Rabaud, W.
    Guellec, F.
    Dupont, B.
    Martin, S.
    Simon, A. C.
    TERAHERTZ EMITTERS, RECEIVERS, AND APPLICATIONS IV, 2013, 8846