Ex vivo investigation on the postoperative integrity of the apical constriction after the sole use of electronic working length determination

被引:6
|
作者
Wolgin, Michael [1 ]
Grundmann, Markus J. [1 ]
Tchorz, Joerg P. [1 ,2 ]
Frank, Wilhelm [3 ]
Kielbassa, Andrej M. [1 ]
机构
[1] DPU, Univ Dent Med & Oral Hlth, Ctr Operat Dent Periodontol & Endodontol, Steiner Landstr 124, A-3500 Krems, Austria
[2] Albert Ludwigs Univ, Univ Freiburg, Med Ctr, Dept Operat Dent & Periodontol,Ctr Dent Med, Hugstetterstr 55, D-79106 Freiburg, Germany
[3] DPU, Univ Dent Med & Oral Hlth, Dept Biostat, Ctr Preclin Educ, Steiner Landstr 124, A-3500 Krems, Austria
关键词
Apical constriction; Electronic working length determination; Radiation dosis; Radiation protection; Root canal preparation; Root canal therapy; APEX LOCATORS; CANAL INSTRUMENTATION; COMPUTED-TOMOGRAPHY; TEACHING MODEL; ROOT-ZX; ACCURACY; TEETH; RADIOGRAPHS; FORAMEN; QUALITY;
D O I
10.1016/j.jdent.2017.06.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The present study investigated the accuracy of root canal preparation with regard to the integrity of the apical constriction (AC) using two different working length determination approaches: (1) the electronic method of working length determination (EWLD), and (2) the radiologic "gold standard" method (GS). Methodology: Simulation models were constructed by arranging extracted human teeth by means of silicon bolstered gingiva masks, along with a conductive medium (alginate). Electronic working length determination (group 1; EWLD) and radiologic plus initial electronic working length determination for posterior comparability (group 2; GS) preceded manual root canal preparation of teeth in both groups. Master cones were inserted according to working lengths obtained from the group specific method. Subsequently, root apices (n = 36) were longitudinally sectioned using a diamond-coated bur. The distance between the achieved apical endpoint of the endodontic preparation and the apical constriction (AC) was measured using digital photography. Then, distances between radiologically identified apical endpoints and AC (GS-AC) were compared with the corresponding distances EWLD-AC. Moreover, the postoperative status of the AC was examined with regard to both preparation approaches. Results: Differences between distances GS-AC and EWLD-AC were not statistically significant (p > 0.401) (Mann-Whitney-U). Among EWLD samples, 83% of the master cones exhibiting tugback at final insertion terminated close to the apical constriction (+/- 0.5 mm), and no impairment of the minor diameter's integrity was observed. Conclusions: The sole use of EWLD allowed for a high accuracy of measurements and granted precise preparation of the apical regions.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 29 条
  • [11] Accuracy of working length determination with root ZX apex locator and radiography: An in vivo and ex vivo study
    Zand, Vahid
    Mokhtari, Hadi
    Lotfi, Mehrdad
    Reyhani, Mohammad Forough
    Sohrabi, Aydin
    Tehranchi, Pardis
    Zenouzi, Hamid Reza Mokhtari
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (36): : 7088 - 7091
  • [12] Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment
    Miguita, Kenner Bruno
    de Araujo, Roberta Aranha
    De Martin, Alexandre Sigrist
    da Silveira Bueno, Carlos Eduardo
    Cunha, Rodrigo Sanches
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (04): : 281 - 284
  • [13] Effectiveness of a new electronic apex locator in two modalities in detecting the working length: an ex vivo study
    Castagnola, Raffaella
    Diana, Rosalba
    Colangeli, Mauro
    Panzetta, Claudia
    Marigo, Luca
    Grande, Nicola Maria
    Plotino, Gianluca
    GIORNALE ITALIANO DI ENDODONZIA, 2021, 35 (01): : 24 - 30
  • [15] A comparison between in vivo radiographic working length determination and measurement after extraction
    Williams, Clayton B.
    Joyce, Anthony P.
    Roberts, Steven
    JOURNAL OF ENDODONTICS, 2006, 32 (07) : 624 - 627
  • [16] Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study
    Maayan Shacham
    Avi Levin
    Avi Shemesh
    Alex Lvovsky
    Joe Ben Itzhak
    Michael Solomonov
    BDJ Open, 6
  • [17] Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study
    Shacham, Maayan
    Levin, Avi
    Shemesh, Avi
    Lvovsky, Alex
    Ben Itzhak, Joe
    Solomonov, Michael
    BDJ OPEN, 2020, 6 (01)
  • [18] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Wolf, Thomas Gerhard
    Krauss-Mironjuk, Anna
    Wierichs, Richard Johannes
    Briseno-Marroquin, Benjamin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [19] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Thomas Gerhard Wolf
    Anna Krauß-Mironjuk
    Richard Johannes Wierichs
    Benjamín Briseño-Marroquín
    Scientific Reports, 11
  • [20] An in vivo comparison of working length determination of two frequency-based electronic apex locators
    Pascon, E. A.
    Marrelli, M.
    Congi, O.
    Ciancio, R.
    Miceli, F.
    Versiani, M. A.