摘要
Obtaining precise timing information from semiconductor gamma-ray detectors is of great interest for a variety of applications such as high-resolution positron emission tomography. However, pulse timing with these detectors through the common constant-fraction discrimination (CFD) method is strongly affected by the time-walk error that results from the inherent variations in the shape of the detectors' pulses. This paper reports on the use of the wavelet transform for minimizing the time-walk error in digital CFD pulse timing with semiconductor gamma-ray detectors. The details of the method are described, and the experimental results with a 1 mm thick CdTe detector are shown. It is demonstrated that, by using the Haar wavelet transform of the digitized preamplifier pulses, the original tailed time spectrum of the detector with a time resolution of 8.22 +/- 0.12 ns at full-width at half-maximum (FWHM) in the energy range of 300-550 keV improves to a symmetric time spectrum with a time resolution of 3.39 +/- 0.02 ns (FWHM). (C) 2018 Author(s).
引用
收藏
页数:6
相关论文
共 50 条
  • [21] TOTAL EFFICIENCY OF GAMMA-RAY DETECTION BY GERMANIUM SEMICONDUCTOR DETECTORS
    GRAUDYNYA, LY
    PELEKIS, LL
    KALNYN, YRH
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1971, 9 (02): : 341 - +
  • [22] Gamma-ray imaging with low fold segmented semiconductor detectors
    Mihailescu, L
    Gast, W
    Lieder, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 20 - 24
  • [23] PULSE FILTERING TECHNIQUES FOR MERCURIC IODIDE GAMMA-RAY DETECTORS
    GERRISH, VM
    BEYERLE, AG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (02): : 220 - 226
  • [24] PARALLEL PULSE PROCESSING FOR MERCURIC IODIDE GAMMA-RAY DETECTORS
    BEYERLE, A
    GERRISH, V
    HULL, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 443 - 449
  • [25] Pulse filtering and correction for CZT detectors using simple digital algorithms based on the wavelet transform
    Perez, JM
    Garcia-Belmonte, G
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 187 - 192
  • [26] Digital gamma-ray tracking algorithms in segmented germanium detectors
    Pearson, CJ
    Dobón, JJV
    Regan, PH
    Sellin, PJ
    Morton, E
    Nolan, PJ
    Boston, A
    Descovich, M
    Thornhill, J
    Cresswell, J
    Lazarus, I
    Simpson, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1209 - 1215
  • [27] A digital signal processing module for gamma-ray tracking detectors
    Cromaz, M.
    Riot, V. J.
    Fallon, P.
    Gros, S.
    Holmes, B.
    Lee, I. Y.
    Macchiavelli, A. O.
    Vu, C.
    Yaver, H.
    Zimmermann, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 597 (2-3): : 233 - 237
  • [28] A method to improve spectral resolution in planar semiconductor gamma-ray detectors
    Keele, BD
    Addleman, RS
    Troyer, GL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1365 - 1368
  • [29] Semiconductor drift detectors for X- and gamma-ray spectroscopy and imaging
    Fiorini, C.
    Longoni, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10): : 2173 - 2181
  • [30] A method to improve spectral resolution in planar semiconductor gamma-ray detectors
    Keele, BD
    Addleman, RS
    Troyer, GL
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 122 - 125