Digital pulse timing with semiconductor gamma-ray detectors using a wavelet transform technique

被引:1
|
作者
Nakhostin, M. [1 ]
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
RESOLUTION; HOT;
D O I
10.1063/1.5050074
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Obtaining precise timing information from semiconductor gamma-ray detectors is of great interest for a variety of applications such as high-resolution positron emission tomography. However, pulse timing with these detectors through the common constant-fraction discrimination (CFD) method is strongly affected by the time-walk error that results from the inherent variations in the shape of the detectors' pulses. This paper reports on the use of the wavelet transform for minimizing the time-walk error in digital CFD pulse timing with semiconductor gamma-ray detectors. The details of the method are described, and the experimental results with a 1 mm thick CdTe detector are shown. It is demonstrated that, by using the Haar wavelet transform of the digitized preamplifier pulses, the original tailed time spectrum of the detector with a time resolution of 8.22 +/- 0.12 ns at full-width at half-maximum (FWHM) in the energy range of 300-550 keV improves to a symmetric time spectrum with a time resolution of 3.39 +/- 0.02 ns (FWHM). (C) 2018 Author(s).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Recent developments in semiconductor gamma-ray detectors
    P. N. Luke
    M. Amman
    C. Tindall
    J. S. Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 145 - 153
  • [2] Recent developments in semiconductor gamma-ray detectors
    Luke, PN
    Amman, M
    Tindall, C
    Lee, JS
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (01) : 145 - 153
  • [3] WALK AND DISPERSION IN LEADING-EDGE TIMING WITH PLANAR SEMICONDUCTOR GAMMA-RAY DETECTORS
    ELIBIARY, MY
    ELKHARAD.LA
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01): : 49 - 53
  • [4] A correlation-based pulse detection technique for gamma-ray/neutron detectors
    Faisal, Muhammad
    Schiffer, Randolph T.
    Flaska, Marek
    Pozzi, Sara A.
    Wentzloff, David D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 479 - 482
  • [5] Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors
    Joshi, S.
    Kaye, W.
    Jaworski, J.
    He, Z.
    MEDICAL PHYSICS, 2015, 42 (06) : 3202 - 3203
  • [6] Real time digital pulse processing for X-ray and gamma ray semiconductor detectors
    Abbene, L.
    Gerardi, G.
    Principato, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 : 124 - 128
  • [7] Signals induced in semiconductor gamma-ray imaging detectors
    Eskin, JD
    Barrett, HH
    Barber, HB
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) : 647 - 659
  • [8] IMPACT OF SEMICONDUCTOR DETECTORS ON GAMMA-RAY AND ELECTRON SPECTROSCOPY
    HOLLANDER, JM
    NUCLEAR INSTRUMENTS & METHODS, 1966, 43 (01): : 65 - +
  • [9] SEMICONDUCTOR DETECTORS FOR GAMMA-RAY SPECTROSCOPY OF SHIELDED SOURCES
    SPIERS, EW
    LAKEY, JRA
    JOURNAL OF THE INSTITUTION OF NUCLEAR ENGINEERS, 1973, 14 (05): : 138 - 142
  • [10] CALCULATION OF AMPLITUDE SPECTRA OF SEMICONDUCTOR GAMMA-RAY DETECTORS
    KATKOV, VP
    KRUPMAN, AI
    TAKSAR, IM
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1973, 7 (12): : 1521 - 1524