Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope

被引:20
|
作者
Blancett, Candace D. [1 ]
Fetterer, David P. [2 ]
Koistinen, Keith A. [1 ,6 ]
Morazzani, Elaine M. [3 ,5 ]
Monninger, Mitchell K. [1 ]
Piper, Ashley E. [3 ]
Kuehl, Kathleen A. [1 ]
Kearney, Brian J. [4 ]
Norris, Sarah L. [2 ]
Rossi, Cynthia A. [4 ]
Glass, Pamela J. [3 ]
Sun, Mei G. [1 ]
机构
[1] US Army, Med Res Inst Infect Dis USAMRIID, Pathol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[2] US Army, Med Res Inst Infect Dis USAMRIID, Biostat Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[3] US Army, Med Res Inst Infect Dis USAMRIID, Virol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[4] US Army, Med Res Inst Infect Dis USAMRIID, Diagnost Syst Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[5] Gen Dynam Informat Technol, 321 Ballenger Ctr Dr, Ft Detrick, MD 21702 USA
[6] US Army, Publ Hlth Ctr, Toxicol Directorate, 5158 Blackhawk Rd, Aberdeen Proving Ground, MD 21010 USA
关键词
Scanning Transmission Electron Microscopy; Detector; Virus quantitation; EQUINE-ENCEPHALITIS-VIRUS; TO-PFU RATIO; PARTICLES; ENUMERATION; RETROVIRUS; ASSAY;
D O I
10.1016/j.jviromet.2017.06.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter.
引用
收藏
页码:136 / 144
页数:9
相关论文
共 50 条
  • [41] Biological applications of the scanning transmission electron microscope
    Engel, Andreas
    JOURNAL OF STRUCTURAL BIOLOGY, 2022, 214 (02)
  • [42] Direct imaging of electron density with a scanning transmission electron microscope
    Ondrej Dyck
    Jawaher Almutlaq
    David Lingerfelt
    Jacob L. Swett
    Mark P. Oxley
    Bevin Huang
    Andrew R. Lupini
    Dirk Englund
    Stephen Jesse
    Nature Communications, 14
  • [44] Direct imaging of electron density with a scanning transmission electron microscope
    Dyck, Ondrej
    Almutlaq, Jawaher
    Lingerfelt, David
    Swett, Jacob L.
    Oxley, Mark P.
    Huang, Bevin
    Lupini, Andrew R.
    Englund, Dirk
    Jesse, Stephen
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [45] CONTRAST IN TRANSMISSION SCANNING ELECTRON-MICROSCOPE
    KANAYA, K
    NISHIKOR.Y
    JOURNAL OF ELECTRON MICROSCOPY, 1972, 21 (03): : 206 - 206
  • [46] IMAGE CONTRAST IN A TRANSMISSION SCANNING ELECTRON MICROSCOPE
    COWLEY, JM
    APPLIED PHYSICS LETTERS, 1969, 15 (02) : 58 - &
  • [47] SECONDARY ELECTRON IMAGING IN THE SCANNING TRANSMISSION ELECTRON MICROSCOPE.
    Allen, R.M.
    Scanning Electron Microscopy, 1985, v : 905 - 918
  • [48] Transmission imaging on a scintillator in a scanning electron microscope
    Zuidema, Wilco
    Kruit, Pieter
    ULTRAMICROSCOPY, 2020, 218 (218)
  • [49] OBSERVATION OF BIOLOGICAL SPECIMENS USING THE SCANNING-TRANSMISSION ELECTRON-MICROSCOPE EQUIPPED WITH SECONDARY-ELECTRON DETECTOR
    TAMURA, E
    KATOH, M
    YAMAMOTO, I
    JOURNAL OF ELECTRON MICROSCOPY, 1982, 31 (03): : 333 - 333
  • [50] Scanning moire fringe imaging by scanning transmission electron microscopy
    Su, Dong
    Zhu, Yimei
    ULTRAMICROSCOPY, 2010, 110 (03) : 229 - 233