A Meta-Analysis and Investigation for the Source of Bias of Left Ventricular Volumes and Function by Three-Dimensional Echocardiography in Comparison With Magnetic Resonance Imaging

被引:90
|
作者
Shimada, Yuichi J. [2 ,3 ]
Shiota, Takahiro [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Noninvas Cardiol Lab, Cedars Sinai Med Ctr,Heart Inst, Los Angeles, CA 90095 USA
[2] Univ Hosp, Beth Israel Med Ctr, Dept Med, New York, NY USA
[3] Albert Einstein Coll Med, New York, NY USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2011年 / 107卷 / 01期
关键词
EJECTION FRACTION; RADIAL STRAIN; TIME; QUANTIFICATION; DYSSYNCHRONY; ADULTS; MASS;
D O I
10.1016/j.amjcard.2010.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Determining accurate left ventricular (LV) function is clinically important. Three-dimensional echocardiography (3DE) achieves better estimation than 2-dimensional echocardiography. However, underestimation of LV volumes has often been reported without a systematic attempt to synthesize these data. This meta-analysis aimed to assess the bias of 3DE in evaluating LV volumes and ejection fraction (EF) and to investigate factors affecting that bias. Studies that compared LV volumes and/or EF between 3DE and magnetic resonance imaging were eligible. Meta-analysis of 95 studies including 3,055 subjects revealed significant underestimation of LV end-systolic volume (-4.7 ml, p < 0.0001) and end-diastolic volume (-9.9 ml, p < 0.0001), whereas measurement for EF revealed excellent accuracy (-0.13%, p = 0.41). Meta-regression analysis for factors of systematic bias in volumetry revealed that female gender and existence of cardiac disease were associated with more underestimation, whereas use of semiautomatic tracking and matrix-array transducers counteracted the underestimation. In conclusion, by meta-analysis synthesizing many small studies, we found underestimation of LV volumes and factors affecting the systematic bias by 3DE. These data provide a more detailed basis for analyzing and improving the accuracy of 3DE, an indispensable step toward further clinical application in LV assessment. (c) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:126-138)
引用
收藏
页码:126 / 138
页数:13
相关论文
共 50 条
  • [41] Assessment of left ventricular volumes by use of one-, two-, and three-dimensional echocardiography versus magnetic resonance imaging in healthy dogs
    Meyer, Judith
    Wefstaedt, Patrick
    Dziallas, Peter
    Beyerbach, Martin
    Nolte, Ingo
    Hungerbuehler, Stephan O.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2013, 74 (09) : 1223 - 1230
  • [42] Reliability and accurate quantification of left ventricular size and function by ultrafast (freehand) three-dimensional echocardiography in patients with normal and abnormal left ventricles: Comparison with magnetic resonance imaging
    De Castro, S
    Pelliccia, A
    Serdoz, LV
    De Santis, M
    Adorisio, R
    Papetti, F
    Di Russo, C
    Fedele, F
    Pandian, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 420A - 421A
  • [43] Evaluation of the left ventricle with three-dimensional echocardiography: Comparison with cardiac magnetic resonance
    Claver, E.
    Leta, R.
    Pujadas, S.
    Hidalgo, A.
    Carreras, F.
    Pons-Llado, G.
    RADIOLOGIA, 2010, 52 (06): : 534 - 540
  • [44] The use of real-time three-dimensional echocardiography for the quantification of left ventricular volumes and function
    Mor-Avi, Victor
    Lang, Roberto M.
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (05) : 402 - 409
  • [45] Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) : 159 - 168
  • [46] Assessment of right-ventricular size and function by real-time three-dimensional echocardiography - comparison with magnetic resonance imaging
    Leibundgut, G.
    Rohner, A.
    Kessel, A.
    Bernheim, A.
    Zellweger, M.
    Buser, P.
    Handke, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 114 - 114
  • [47] Comparison of cardiac computed tomography to magnetic resonance imaging: left ventricular volumes and function
    Groothuis, J. G. J.
    Fransen, M.
    Beek, A. M.
    Brinckman, S. L.
    Meijerink, M. R.
    Hofman, M. B. M.
    Van Kuijk, C.
    Van Rossum, A. C.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A77 - A77
  • [48] Real Time Three-Dimensional Echocardiography Correlates With Cardiac Magnetic Resonance Imaging In The Assessment Of Right Ventricular Volumes And Function In Pediatric Pulmonary Hypertension
    Jone, P. -N.
    Truong, U.
    Cassidy, C.
    Patel, S. S.
    DiMaria, M.
    Fonseca, B.
    Younoszai, A. K.
    Ivy, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [49] Real-time three-dimensional echocardiography for assessment of left ventricular function in children: A validation study compared with magnetic resonance imaging
    Munns, S
    Bu, LP
    Zhang, HH
    Disterhoft, M
    Dixon, M
    Stolpen, A
    Sonka, M
    Mahoney, L
    Ge, SP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 344A - 344A
  • [50] Accuracy and sensitivity of three-dimensional echocardiography to detect changes in right ventricular volumes: comparison study with cardiac magnetic resonance
    K. A. Myhr
    C. B. Kristensen
    F. H. G. Pedersen
    C. Hassager
    N. Vejlstrup
    R. Mattu
    R. Pecini
    R. Mogelvang
    The International Journal of Cardiovascular Imaging, 2021, 37 : 493 - 502