A Meta-Analysis and Investigation for the Source of Bias of Left Ventricular Volumes and Function by Three-Dimensional Echocardiography in Comparison With Magnetic Resonance Imaging

被引:90
|
作者
Shimada, Yuichi J. [2 ,3 ]
Shiota, Takahiro [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Noninvas Cardiol Lab, Cedars Sinai Med Ctr,Heart Inst, Los Angeles, CA 90095 USA
[2] Univ Hosp, Beth Israel Med Ctr, Dept Med, New York, NY USA
[3] Albert Einstein Coll Med, New York, NY USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2011年 / 107卷 / 01期
关键词
EJECTION FRACTION; RADIAL STRAIN; TIME; QUANTIFICATION; DYSSYNCHRONY; ADULTS; MASS;
D O I
10.1016/j.amjcard.2010.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Determining accurate left ventricular (LV) function is clinically important. Three-dimensional echocardiography (3DE) achieves better estimation than 2-dimensional echocardiography. However, underestimation of LV volumes has often been reported without a systematic attempt to synthesize these data. This meta-analysis aimed to assess the bias of 3DE in evaluating LV volumes and ejection fraction (EF) and to investigate factors affecting that bias. Studies that compared LV volumes and/or EF between 3DE and magnetic resonance imaging were eligible. Meta-analysis of 95 studies including 3,055 subjects revealed significant underestimation of LV end-systolic volume (-4.7 ml, p < 0.0001) and end-diastolic volume (-9.9 ml, p < 0.0001), whereas measurement for EF revealed excellent accuracy (-0.13%, p = 0.41). Meta-regression analysis for factors of systematic bias in volumetry revealed that female gender and existence of cardiac disease were associated with more underestimation, whereas use of semiautomatic tracking and matrix-array transducers counteracted the underestimation. In conclusion, by meta-analysis synthesizing many small studies, we found underestimation of LV volumes and factors affecting the systematic bias by 3DE. These data provide a more detailed basis for analyzing and improving the accuracy of 3DE, an indispensable step toward further clinical application in LV assessment. (c) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:126-138)
引用
收藏
页码:126 / 138
页数:13
相关论文
共 50 条
  • [1] ACCURACY OF LEFT VENTRICULAR VOLUMES AND FUNCTION DETERMINED BY 3-DIMENSIONAL ECHOCARDIOGRAPHY VALIDATED BY MAGNETIC RESONANCE IMAGING: A META-ANALYSIS AND INVESTIGATION FOR THE SOURCE OF BIAS
    Shimada, Yuichi J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [2] Underestimation of Left Atrial Volume by Three-Dimensional Echocardiography Validated by Magnetic Resonance Imaging: A Meta-Analysis and Investigation of the Source of Bias
    Shimada, Yuichi J.
    Shiota, Takahiro
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (04): : 385 - 390
  • [3] Accuracy of Right Ventricular Volumes and Function Determined by Three-Dimensional Echocardiography in Comparison with Magnetic Resonance Imaging: A Meta-Analysis Study
    Shimada, Yuichi J.
    Shiota, Maiko
    Siegel, Robert J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 943 - 953
  • [4] UNDERESTIMATION OF LEFT VENTRICULAR MASS BY 3-DIMENSIONAL ECHOCARDIOGRAPHY VALIDATED BY MAGNETIC RESONANCE IMAGING: A META-ANALYSIS AND INVESTIGATION OF THE SOURCE OF BIAS
    Shimada, Yuichi J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E753 - E753
  • [5] Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function
    Kleijn, Sebastiaan A.
    Brouwer, Wessel P.
    Aly, Mohamed F. A.
    Russel, Iris K.
    de Roest, Gerben J.
    Beek, Aernout M.
    van Rossum, Albert C.
    Kamp, Otto
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (10) : 834 - 839
  • [6] Left ventricular sphericity: comparison of three-dimensional echocardiography and cardiac magnetic resonance imaging
    Patel, A. A.
    Onuora, A. A.
    Toole, R. S.
    Goldman, M.
    Alexander, D.
    Gupta, D.
    Kadiyala, M.
    Cao, J.
    Reichek, N.
    Gopal, A. S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 883 - 883
  • [7] Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
    Jenkins, Carly
    Moir, Stuart
    Chan, Jonathan
    Rakhit, Dhrubo
    Haluska, Brian
    Marwick, Thomas H.
    EUROPEAN HEART JOURNAL, 2009, 30 (01) : 98 - 106
  • [8] Underestimation of Left Atrial Volume by 3-Dimensional Echocardiography Validated by Magnetic Resonance Imaging: A Meta-Analysis and Investigation of the Source of Bias
    Shimada, Yuichi J.
    Shiota, Takahiro
    CIRCULATION, 2010, 122 (21)
  • [9] ACCURACY OF RIGHT VENTRICULAR VOLUMES AND FUNCTION DETERMINED BY 3-DIMENSIONAL ECHOCARDIOGRAPHY IN COMPARISON WITH MAGNETIC RESONANCE IMAGING: A META-ANALYSIS STUDY
    Shimada, Yuichi J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [10] Quantification of left ventricular volumes and ejection fraction using freehand transthoracic three-dimensional echocardiography: Comparison with magnetic resonance imaging
    Mannaerts, HFJ
    van der Heide, JA
    Kamp, O
    Papavassiliu, T
    Marcus, JT
    Beek, A
    van Rossum, AC
    Twisk, J
    Visser, CA
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (02) : 101 - 109