Absolute frequency measurement of the HeNe/I2 standard at 633 nm

被引:23
|
作者
Bernard, JE [1 ]
Madej, AA [1 ]
Siemsen, KJ [1 ]
Marmet, L [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
optical frequency standard; single ion; frequency chain;
D O I
10.1016/S0030-4018(00)01085-3
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The absolute frequency of a HeNe laser locked to a hyperfine component in I-127(2) is measured using a frequency standard based on a single, trapped and laser-cooled Sr-88(+) ion. A CO2 laser, whose frequency is measured with a Cs-based frequency chain, is used to span the frequency interval between the ion standard at 445 THz and the HeNe/I-2 laser at 474 THz. The frequency of the f component of the 11-5 R(127) transition of our HeNe/I-2 standard laser is found to be 473 612 353 600 180 +/- 720 Hz at the exact operating conditions specified for the realization of the recommended value of this radiation. Crown Copyright (C) 2001 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 50 条
  • [41] Strong hyperfine spectra of 127I2 at 633 nm and frequency stabilized tunable diode laser
    Zhang, KM
    Cheng, XZ
    Zang, EJ
    Akimoto, Y
    Kasahara, T
    Sakamoto, K
    Inaba, H
    ACTA PHYSICA SINICA, 1999, 48 (05) : 840 - 849
  • [42] Strong hyperfine spectra of 127I2 at 633 nm and frequency stabilized tunable diode laser
    Zhang, Ke-Ming
    Chen, Xu-Zong
    Zang, Er-Jun
    Akimoto, Yoshiaki
    Kasahara, Takeshi
    Sakamoto, Katsuhira
    Inaba, Hajime
    Wuli Xuebao/Acta Physica Sinica, 1999, 48 (05):
  • [43] Linking the 474 THz HeNe/I2 standard to the 445 THz single Sr+ trapped ion standard:: Heterodyne frequency measurements using an OsO4 stabilized 29 THz laser system
    Madej, AA
    Siemsen, KJ
    Marmet, L
    Bernard, JE
    Acef, O
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 553 - 557
  • [44] A 29 TBz OsO4 stabilized reference laser for linking the 474 THz HeNe/I2 optical standard to the 445 THz single strontium ion standard
    Siemsen, KJ
    Madej, AA
    Marmet, L
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 397 - 398
  • [45] Frequency stabilization of a 650 nm laser to an I2 spectrum for trapped 138Ba+ ions
    Xie, Tian
    Jin, Naijun
    Wang, Ye
    Zhang, Junhua
    Um, Mark
    Wang, Pengfei
    Kim, Kihwan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2019, 36 (02) : 243 - 247
  • [46] Effects of column density on I2 spectroscopy and a determination of I2 absorption cross section at 500nm
    Spietz, P.
    Gomez Martin, J.
    Burrows, J. P.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2006, 6 : 2177 - 2191
  • [47] Absolute frequency measurement of an acetylene-stabilized laser at 1542 nm
    Hong, FL
    Onae, A
    Jiang, J
    Guo, RX
    Inaba, H
    Minoshima, K
    Schibli, TR
    Matsumoto, H
    Nakagawa, K
    OPTICS LETTERS, 2003, 28 (23) : 2324 - 2326
  • [48] Frequency measurement of I2 lines in the NIR using Ca and CH4 optical frequency standards
    Bodermann, B
    Klug, M
    Knockel, H
    Tiemann, E
    Trebst, T
    Telle, HR
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (01): : 95 - 99
  • [49] Absolute frequency measurement of the molecular iodine hyperfine transitions at 548 nm
    Hsiao, Yu-Chen
    Kao, Cheng-Yang
    Chen, Hsuan-Chen
    Chen, Shih-En
    Peng, Jin-Long
    Wang, Li-Bang
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2013, 30 (02) : 328 - 332
  • [50] Absolute frequency measurement of an acetylene-stabilized laser at 1542 nm
    Hong, FL
    Onae, A
    Jiang, J
    Schibli, TR
    Inaba, H
    Minoshima, K
    Matsumoto, H
    Hartl, I
    Fermann, ME
    2005 DIGEST OF THE LEOS SUMMER TOPICAL MEETINGS, 2005, : 135 - 136