Research on seismic behavior of unbonded post-tensioned concrete wall with vertical energy-dissipating connections

被引:25
|
作者
Dang, Longji [1 ]
Liang, Shuting [1 ]
Zhu, Xiaojun [1 ]
Pang, Rui [2 ]
Yang, Jian [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Nanjing 211189, Peoples R China
[2] Henan Univ Technol, Sch Civil Engn, Zhengzhou 450001, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Post-tensioned concrete wall; Seismic performance; X-shaped metal damper; Self-centering capacity; Energy-dissipating capacity; PERFORMANCE; DESIGN; SYSTEMS;
D O I
10.1016/j.jobe.2021.103478
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An unbonded post-tensioned (PT) concrete wall system with vertical energy-dissipating connections (UPTWVEC) is proposed that consists of precast wall panels, several X-shaped metal dampers (XMD), mild steel energydissipating bars (ED bars) and PT tendons. In this wall system, the precast wall panels are assembled through XMDs along the vertical joints and ED bars along the horizonal joints to provide the energy-dissipating capacity. The PT tendons installed at the wall toes are used to provide the self-centering capacity. In addition, each wall toe is protected by a steel jacket from the concrete corners spalling or crushing. Firstly, the hysteretic behavior of XMD was studied experimentally. Then, the seismic behavior of the unbonded post-tensioning concrete wall with different parameters were investigated experimentally based on four specimens. It was shown that the wall panels were resilient after tests and the cracks were only observed near the embedded plate in wall panels. In addition, a simplified analysis method was proposed, and the theoretical results matched well with the experimental results. Finally, the finite element analysis (FEA) model of UPTW-VEC was established. Following validating through the experimental results, a parametric study was conducted to investigate the influence of critical parameters on the seismic behavior of UPTW-VEC.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections
    Cheng, Chin-Tung
    COMPUTERS AND CONCRETE, 2008, 5 (06): : 525 - 544
  • [32] Seismic behavior of unbonded post-tensioned precast concrete members with thin rubber layers at the jointed connection
    Kalliontzis, Dimitrios
    Sritharan
    PCI JOURNAL, 2021, 66 (01): : 60 - 76
  • [34] Seismic design of unbonded post-tensioned precast concrete walls with supplemental viscous damping
    Kurama, YC
    ACI STRUCTURAL JOURNAL, 2000, 97 (04) : 648 - 658
  • [35] BEHAVIOR AND DESIGN OF MULTISTORY BUILDING FRAMES OF UNBONDED POST-TENSIONED CONCRETE.
    Waller, James E.
    Zimmerman, John E.
    1600, (82):
  • [36] Seismic design and response evaluation of unbonded post-tensioned hybrid coupled wall structures
    Kurama, Yahya C.
    Shen, Qiang
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (14): : 1677 - 1702
  • [37] Optimum seismic design of unbonded post-tensioned precast concrete walls using ANN
    Abdalla, Jamal A.
    Saqan, Elias I.
    Hawileh, Rami A.
    COMPUTERS AND CONCRETE, 2014, 13 (04): : 547 - 567
  • [38] Flexural behavior of ungrouted post-tensioned concrete masonry beams with unbonded bars
    Garcia, John M.
    Bonett, Ricardo L.
    Schultz, Arturo E.
    Carrillo, Julian
    Ledezma, Christian
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 203 : 210 - 221
  • [39] Experimental testing of post-tensioned steel-timber hybrid frames equipped with energy-dissipating braces
    Chen, Fei
    Li, Zheng
    Li, Minghao
    Shu, Zhan
    ENGINEERING STRUCTURES, 2023, 296
  • [40] Cyclic testing of unbonded post-tensioned concrete wall systems with and without supplemental damping
    Twigden, K. M.
    Sritharan, S.
    Henry, R. S.
    ENGINEERING STRUCTURES, 2017, 140 : 406 - 420