Characterization of RF and Microwave Measurement Cables Used with Vector Network Analyzers

被引:1
|
作者
Moder, Martin [1 ]
Schubert, Joachim [1 ]
机构
[1] Rosenberger, Fridolfing, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A vector network analyzer (VNA) is as useful as the accuracy of the measurements it makes, and this requires the instrument to be calibrated. Very often those measurements need a test setup that includes not only the VNA and a calibration kit but also one or more measurement cables and adapters. The calibration process employs a technique called vector error correction, in which error terms are characterized using known standards so that errors can be removed from actual measurements. The process of removing these errors requires the errors and measured quantities to be measured vectorially (thus the need for a VNA). Directly after this calibration process, the best measurement accuracy can be expected. Changing anything may decrease measurement accuracy. Typically influences are temperature changes, bending/movement of the measurement cables, vibration and drift. This article concentrates on the measurement cables. It clarifies why and how cable bending and movement influence the accuracy and how measurement cables can be characterized to estimate their influence on the accuracy.
引用
收藏
页码:82 / 92
页数:11
相关论文
共 50 条
  • [31] CALIBRATION OF NETWORK ANALYZERS FOR TUNER CHARACTERIZATION
    TSIRONIS, C
    MICROWAVE JOURNAL, 1994, 37 (11) : 116 - &
  • [32] ESTIMATION OF RESIDUAL ERROR PARAMETERS FOR VECTOR NETWORK ANALYZERS
    Wuebbeler, Gerd
    Judaschke, Rolf
    Elster, Clemens
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 950 - 952
  • [33] A Nonlinear Verification Device for Nonlinear Vector Network Analyzers
    Humphreys, David A.
    Rajabi, Mohammad
    Schreurs, Dominique
    Nielsen, Troels
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [34] Network vector analyzers set new performance standards
    Allan, Roger
    Electronic Design, 2000, 48 (19)
  • [36] LRL CALIBRATION OF VECTOR AUTOMATIC NETWORK ANALYZERS.
    Maury Jr., Mario A.
    March, Steven L.
    Simpson, Gary R.
    Microwave journal, 1987, 30 (05): : 387 - 388
  • [37] Calibration comparison for vector network analyzers with switching errors
    Marks, RB
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 491 - 491
  • [38] A NEW ELECTRONIC VERIFICATION METHOD FOR VECTOR NETWORK ANALYZERS
    Ginley, R.
    Williams, D.
    LeGolvan, D.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 587 - 588
  • [39] IMPROVING TRL(ASTERISK) CALIBRATIONS OF VECTOR NETWORK ANALYZERS
    METZGER, D
    MICROWAVE JOURNAL, 1995, 38 (05) : 56 - +
  • [40] Measuring capacitor parameters using vector network analyzers
    Stepins, Deniss
    Asmanis, Gundars
    Asmanis, Aivis
    1600, University of Banja Luka, Faculty of Electrical Engineering (18): : 29 - 38