Heat transfer enhancement of flow insulator by combined stainless steel fibrous and wire net porous materials

被引:0
|
作者
Khantikomol, P. [1 ]
Polsongkram, M. [1 ]
Apisitpinyo, W. [1 ]
Poowadin, T. [1 ]
机构
[1] Rajamangala Univ Technol Isan, Fac Engn & Architecture, Dept Mech Engn, Renewable Energy Technol Res Lab RTER, 744 Suranarai Rd, Muang 30000, Nakhonratchasim, Thailand
来源
8TH TSME-INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (TSME-ICOME 2017) | 2018年 / 297卷
关键词
MULTIPHASE MEDIUM; LAMINAR-FLOW; RADIATION;
D O I
10.1088/1757-899X/297/1/012072
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present research article aims to propose the heat transfer enhancement of the flow insulator using combined fibrous and wire net stainless steel porous material. The stainless fibrous plate with porosity of 0.9292 was combined to the stainless steel wire net having pore per inch (PPI) of 16 and total thickness of 30 mm. Two models of the arranging porous plates were prepared, which were model BA and model AB. Each porous plate segment had the same thickness. The examined porous plate model have porosities of 0.8452. The porous plate was placed normal to the flow direction. The air was used as working fluid heated by 5 kW electric heater, which was controlled by the automatic temperature control. Type-K thermocouples were employed to measure the air temperatures. The temperature at front of the porous plate was varied to be 350, 450, and 550 degrees C. The air flow rate was varied in the range of 4-12 m(3)/hr. The experimental result showed that the temperature drop across the porous plate and the thermal efficiency increase with the inlet temperature. The air velocity slightly affects the temperature profile inside the test section at the upstream side of the porous plate but greatly affects temperature inside the porous plate. In consideration of the arranging porous plate, placing of the stainless steel wire net at the upstream side and placing the stainless steel fibrous at downstream side (model BA) results in the highest temperature drop and the highest thermal efficiency. At Re 733 and inlet temperature 550 degrees C for model BA at 30 mm thickness, the thermal efficiency was 50%. It was shown that the combined stainless steel fibrous and stainless steel wire net porous material could be a good flow insulator.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Numerical study on combined convection heat transfer flow problem in a porous corrugated enclosure
    Choudhary, Pankaj
    Ray, Rajendra K.
    HEAT TRANSFER, 2022, 51 (04) : 3279 - 3312
  • [32] Preparation and Flow Boiling Heat Transfer Performance of Concave Cr Coating on Stainless Steel Surface
    Zhao, Qianwen
    Fang, Liang
    Wu, Fang
    Pan, Liangming
    Zhong, Tao
    Zhang, Shufang
    Luo, HaiJun
    INTEGRATED FERROELECTRICS, 2022, 226 (01) : 185 - 203
  • [33] Flow Boiling Heat Transfer Enhancement Using Novel Dual-Channel Design with Femtosecond Laser Surface Processed Stainless Steel Surfaces
    Pettit, Logan
    Costa-Greger, Justin
    Reicks, Andrew
    Sarin, Suchit
    Shield, Jeffrey
    Zuhlke, Craig
    Gogos, George
    InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITHERM, 2023, 2023-May
  • [34] Numerical configuration design and investigation of heat transfer enhancement in pipes filled with gradient porous materials
    Wang, Baicun
    Hong, Yifeng
    Hou, Xiangtao
    Xu, Zhongbin
    Wang, Pengfei
    Fang, Xudong
    Ruan, Xiaodong
    ENERGY CONVERSION AND MANAGEMENT, 2015, 105 : 206 - 215
  • [35] Effect of wire coil inserts on heat transfer enhancement and fluid flow characteristics of a double-pipe heat exchanger
    Brajesh Kumar Ahirwar
    Arvind Kumar
    Journal of Thermal Analysis and Calorimetry, 2024, 149 : 3027 - 3042
  • [36] Effect of wire coil inserts on heat transfer enhancement and fluid flow characteristics of a double-pipe heat exchanger
    Ahirwar, Brajesh Kumar
    Kumar, Arvind
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (07) : 3027 - 3042
  • [37] Fully developed heat transfer to fluid flow in rectangular passages filled with porous materials
    Haji-Sheikh, A
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2006, 128 (06): : 550 - 556
  • [38] FLOW AND HEAT-TRANSFER OF SINGLE-PHASE COOLANT IN POROUS CERMET MATERIALS
    MAIOROV, VA
    THERMAL ENGINEERING, 1978, 25 (01) : 59 - 65
  • [39] Reciprocating turbulent flow heat transfer enhancement within a porous medium embedded in a circular tube
    Saberinejad, Hojjat
    Keshavarz, Ali
    APPLIED THERMAL ENGINEERING, 2016, 102 : 1355 - 1365
  • [40] Analysis for heat transfer enhancement in the core flow of a tube filled with porous media at different layers
    Liu, Wei
    Ming, Ting-Zhen
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (32): : 66 - 71