Estimation on amount of steel reinforcement for six storey hospital building with seismic design consideration in Malaysia

被引:2
|
作者
Adiyanto, M., I [1 ]
Jani, F. Ahmad [1 ]
Mustapha, S. A. H. S. [2 ,3 ]
Ahmad, S. W. [1 ]
机构
[1] Univ Malaysia Pahang, Fac Civil Engn & Earth Resources, Gambang 26300, Pahang, Malaysia
[2] Univ Teknol MARA, Fac Architecture Planning & Surveying, Dept Quant Surveying, Seri Iskandar, Perak, Malaysia
[3] AS2 Consult Sdn Bhd, Seri Iskandar, Perak, Malaysia
来源
NATIONAL COLLOQUIUM ON WIND AND EARTHQUAKE ENGINEERING | 2019年 / 244卷
关键词
D O I
10.1088/1755-1315/244/1/012015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of earthquakes such as Sumatra-Andaman earthquake on 26 December 2004, Nias earthquake on 28 March 2005, and Bengkulu earthquake on 12 December 2007 had influences to a series of subsequence local earthquake in Peninsular Malaysia. Recently, East Malaysia especially Sabah has become earthquake prone region due to local fault. Hence, Malaysia is not totally free from seismic activities. Therefore, in 2009 Malaysian Public Work Department had concluded that it was worthwhile to consider seismic design input in new building which are located in medium to high risk earthquake zone. The effect of seismic design implementation on cost of materials has become an interesting topic to discuss. This study presents the estimation of steel reinforcement required for six storey hospital building in Malaysia with seismic design consideration. Two parameters namely as reference peak ground acceleration and class of ductility has been considered as variable. The result shows that the total amount of steel reinforcement is increased from 6%, 116%, 257%, and 290% for peak ground acceleration equal to 0.04g, 0.08g, 0.12g, and 0.16g, respectively compared to the non-seismic design counterpart. Beside, total amount of steel reinforcement is increase around 6% and 145% for ductility class medium and ductility class low, respectively compared to its non-seismic design counterpart.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Seismic Risk Assessment of a 2-storey Steel-sheathed CFS Building Considering Different Sources of Uncertainty
    Jiang, Liqiang
    Ye, Jihong
    STRUCTURES, 2018, 16 : 347 - 357
  • [32] A hybrid force/displacement seismic design method for steel building frames
    Tzimas, A. S.
    Karavasilis, T. L.
    Bazeos, N.
    Beskos, D. E.
    ENGINEERING STRUCTURES, 2013, 56 : 1452 - 1463
  • [33] Recording inter-storey drifts of structures in time-history approach for seismic design of building frames
    Hokmabadi, A. S.
    Fatahi, B.
    Samali, B.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2012, 13 (02) : 175 - 179
  • [34] Seismic Performance of Soft Storey Reinforced Concrete Buildings in Ranau, Sabah Subjected to Design Seismic Load Stipulated in Malaysia National Annex to Eurocode 8
    Ho, Kar Meng
    Lau, Tze Liang
    PROCEEDINGS OF AICCE'19: TRANSFORMING THE NATION FOR A SUSTAINABLE TOMORROW, 2020, 53 : 1563 - 1574
  • [35] Seismic design of special moment-resisting steel frame with prevention of soft-storey mechanism failure
    Alinouri, Hossein
    Danesh, Fakhroddin Ahmadi
    Khazaee, Hamideh
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (11): : 876 - 886
  • [36] The design of an iconic 40-storey steel composite office tower in Indonesia with a high seismic performance level
    Wijanto S.
    Andriono T.
    Wibawa I.
    Setiawan W.
    Key Engineering Materials, 2018, 763 : 1033 - 1040
  • [37] Seismic Design, Analysis and Testing of a Friction Steel Braced Frame System for Multi-Storey Buildings in Vancouver
    Tirca L.
    Serban O.
    Tremblay R.
    Jiang Y.
    Chen L.
    Tremblay, Robert (robert.tremblay@polymtl.ca), 2018, Trans Tech Publications Ltd (763 KEM) : 1077 - 1086
  • [38] Structural health monitoring of a 32-storey steel-frame building using 50 years of seismic monitoring data
    Rahmani, Mohammadtaghi
    Todorovska, Maria I.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (06): : 1777 - 1800
  • [39] Seismic design levels of building structures with different importance factors in.consideration of earthquake environment
    Ma, YH
    Zhao, GF
    Xie, LL
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 219 - 223
  • [40] Automatic generative design and optimization of hospital building layouts in consideration of public health emergency
    Zhou, Ying
    Wang, Yu
    Li, Chenshuang
    Ding, Lieyun
    Wang, Cong
    ENGINEERING CONSTRUCTION AND ARCHITECTURAL MANAGEMENT, 2024, 31 (04) : 1391 - 1407