Simultaneous analysis of 25 trace elements in micro volume of human serum by inductively coupled plasma mass spectrometry (ICP-MS)

被引:25
|
作者
Nawi, Azmawati Mohammed [1 ,2 ]
Chin, Siok-Fong [1 ]
Jamal, Rahman [1 ]
机构
[1] Univ Kebangsaan Malaysia, UKM Med Mol Biol Inst UMBI, Jalan Yaacob Latiff, Kuala Lumpur 56000, Malaysia
[2] Univ Kebangsaan Malaysia, Dept Community Hlth, Med Ctr, Jalan Yaacob Latiff, Kuala Lumpur 56000, Malaysia
关键词
Trace element; Acid digestion; Serum; ICP-MS; REFERENCE VALUES; TOTAL MERCURY; WHOLE-BLOOD; URINE; ADULTS; EXPOSURE; MATRIX; CANCER; RISK;
D O I
10.1016/j.plabm.2019.e00142
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: In recent years, trace elements have gained importance as biomarkers in many chronic diseases. Unfortunately, the requirement for sample volume increases with the extent of investigation either for diagnosis or elucidating the mechanism of the disease. Here, we describe the method development and validation for simultaneous determination of 25 trace elements (lithium [Li], beryllium [Be], magnesium [Mg], aluminium [Al], vanadium [V], chromium [Cr], manganese [Mn], iron [Fe], cobalt [Co], nickel [Ni], copper [Cu], zinc [Zn], gallium [Ga], arsenic [As], selenium [Se], rubidium [Rb], strontium [Sr], silver [Ag], cadmium [Cd], caesium [Cs], barium [Ba], mercury [Hg], thallium [Tl], lead [Pb], uranium [U]) using only 20 mu L of human serum. Methods: Serum samples were digested with nitric acid and hydrochloric acid (ratio 1:1, v/v) and analysed by inductively coupled plasma-mass spectrometry (ICP-MS). Seronorm (R), a human-derived serum control material was used as quality control samples. Results: The coefficient of variations for both intra- and inter-day precisions were consistently <15% for all elements. The validated method was later tested on 30 human serum samples to evaluate its applicability. Conclusion: We have successfully developed and validated a precise and accurate analytical method for determining 25 trace elements requiring very low volume of human serum.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    Vance, DE
    Belt, VF
    Oatts, TJ
    Mann, DK
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 143 - 146
  • [22] Determination of elements in carbon fiber using inductively coupled plasma mass spectrometry (ICP-MS)
    Zhao, Ting
    Zhou, Mingqiang
    Liu, Weili
    Huang, Wei
    He, Junzhi
    Chi, Haitao
    Gao, Xia
    APPLIED MATERIALS AND TECHNOLOGIES FOR MODERN MANUFACTURING, PTS 1-4, 2013, 423-426 : 767 - 770
  • [23] Minor and Trace Element Analysis in Breast Milk Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Liuchun Yang
    Meng Zhang
    Shen Lin
    Dengyun Chen
    Minghui Zheng
    Microchimica Acta, 2003, 142 : 85 - 88
  • [24] Minor and trace element analysis in breast milk using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Yang, LC
    Zhang, M
    Lin, S
    Chen, DY
    Zheng, MH
    MICROCHIMICA ACTA, 2003, 142 (1-2) : 85 - 88
  • [25] APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) TO MULTIELEMENT ANALYSIS OF HUMAN ORGANS
    YOSHINAGA, J
    MATSUO, N
    IMAI, H
    NAKAZAWA, M
    SUZUKI, T
    MORITA, M
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 41 (1-2) : 27 - 38
  • [26] ANALYSIS OF TOXIC ELEMENTS IN LEAVES AND FRUITS OF LOQUAT BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    Ali, Muhammad Moaaz
    Rizwani, Hafiz Muhammad
    Yousef, Ahmed Fathy
    Zhi, Cao
    Chen, Faxing
    ACTA SCIENTIARUM POLONORUM-HORTORUM CULTUS, 2021, 20 (05): : 33 - 42
  • [27] Trace metals in LPG (liquified petroleum gas) by ICP-MS (inductively coupled plasma mass spectrometry)
    Chudasama, Subhadra
    Lehuta, Keith
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [28] Facilitation of trace elemental determination in plutonium oxide by inductively coupled plasma mass spectrometry (ICP-MS)
    Giglio, J
    Cummings, D
    Krsul, J
    PLUTONIUM FUTURES - THE SCIENCE, 2003, 673 : 116 - 116
  • [29] Trace Elemental Analysis of Allium Species by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) with Multivariate Chemometrics
    Oral, Elif Varhan
    Tokul-Olmez, Ozge
    Yener, Ismail
    Firat, Mehmet
    Tunay, Zeki
    Terzioglu, Pinar
    Aydin, Firat
    Ozturk, Mehmet
    Ertas, Abdulselam
    ANALYTICAL LETTERS, 2019, 52 (02) : 320 - 336
  • [30] A comparison of different calibration strategies for the trace analysis of soil samples by inductively coupled plasma mass spectrometry (ICP-MS)
    Botha, Angelique
    METROLOGIA, 2020, 57 (06)